Current Control of Grid-Connected Inverter With LCL Filter Based on Extended-State Observer Estimations Using Single Sensor and Achieving Improved Robust Observation Dynamics

被引:98
|
作者
Wang, Baochao [1 ,2 ]
Xu, Yongxiang [2 ]
Shen, Zhaoyuan [2 ]
Zou, Jibin [1 ,2 ]
Li, Chaoquan [3 ]
Liu, Hong [4 ,5 ]
机构
[1] Harbin Inst Technol, State Key Lab Robot & Syst, Harbin 150001, Peoples R China
[2] Harbin Inst Technol, Sch Elect Engn & Automat, Harbin 150001, Peoples R China
[3] NORINCO, Nav & Control Inst, Beijing 100089, Peoples R China
[4] Harbin Inst Technol, Sch Mechatron Engn, Harbin 150001, Peoples R China
[5] Harbin Inst Technol, State Key Lab Robot & Syst, Harbin 150001, Peoples R China
基金
中国国家自然科学基金;
关键词
Active damping; extended state observer (ESO); grid-connected inverter; grid synchronization; independent of expertise tuning; LCL filter; observer dynamic decoupling; parameter mismatch; single sensor; CONVERTERS;
D O I
10.1109/TIE.2017.2674600
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In the context of distributed generation and renewable energy penetration toward smart grid, grid-connected inverter with LCL filter has drawn many attentions, whose current control conventionally requires several sensors to realize active damping and grid synchronization. In this paper, a novel full status observation strategy based on extended state observer (ESO) is proposed using inverter current feedback only and without grid voltage sensor. The proposed observation strategy contains observation and transformation process. Unlike conventional Luenberger observer, by using ESO, the system parameters do not appear in observation process, thus the observer dynamics and parameter mismatch error can be separately handled, providing more robust observation dynamics during parameter variation. Parameter mismatch study was carried out, and it is found that purposely choosing the observer parameters smaller than the real value can achieve relatively low estimation error and a large adaption range for parameter variation. The proposed observation strategy is simple to implement, without the need of expert knowledge-based parameter tuning such as pole placement. Experimental tests validated that the proposed observation-based control is able to give satisfactory performance in both dynamic and steady states, as well as adaption for system parameter variation.
引用
收藏
页码:5428 / 5439
页数:12
相关论文
共 50 条
  • [31] A Feedforward Compensation Based Decoupling Control Strategy for Grid-Connected Inverter with LCL Filter
    Qu, K.
    Ye, T.
    Zhao, J.
    Chen, X.
    2015 9TH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND ECCE ASIA (ICPE-ECCE ASIA), 2015, : 2463 - 2468
  • [32] Dual Current Feedback Active Damping for Improving Transient Performance of LCL-filter-based Grid-connected Inverter
    Dong, Minghan
    Bai, Zhihong
    Ma, Hao
    2019 IEEE 28TH INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2019, : 828 - 833
  • [33] An Improved Resonant Frequency Based Systematic LCL Filter Design Method for Grid-Connected Inverter
    Wu, Tsai-Fu
    Misra, Mitradatta
    Lin, Li-Chiun
    Hsu, Chih-Wei
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2017, 64 (08) : 6412 - 6421
  • [34] Extended Stable Boundary of LCL-Filtered Grid-Connected Inverter Based on An Improved Grid-Voltage Feedforward Control
    Lu, Minghui
    Xin, Zhen
    Wang, Xiongfei
    Beres, Remus Narcis
    Blaabjerg, Frede
    2016 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2016,
  • [35] LCL Filter Design Based on Ripple Current Minimization Approach for Grid-Connected Inverter Application
    Yaakub, Muhamad Faizal
    Radzi, Mohd Amran Mohd
    Asri, Maaspaliza
    Shafie, Suhaidi
    Azis, Norhafiz
    Noh, Faridah Hanim Mohd
    IEACON 2021: 2021 IEEE INDUSTRIAL ELECTRONICS AND APPLICATIONS CONFERENCE (IEACON), 2021, : 45 - 49
  • [36] PLL-less Robust Active and Reactive Power Controller for Single Phase Grid-Connected Inverter with LCL Filter
    Li, Xiao
    Balog, Robert S.
    2015 THIRTIETH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2015), 2015, : 2154 - 2159
  • [37] Robust State Feedback Current Controller With Harmonic Compensation for Single Stage Grid Connected PV Inverter with LCL Filter
    Sharma, Rishi Kant
    Mishra, Sukumar
    Mudliyar, Shivraman
    2018 IEEMA ENGINEER INFINITE CONFERENCE (ETECHNXT), 2018,
  • [38] Observer-Based State-Space Current Control for a Three-Phase Grid-Connected Converter Equipped With an LCL Filter
    Kukkola, Jarno
    Hinkkanen, Marko
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2014, 50 (04) : 2700 - 2709
  • [39] Stability analysis and improvement for LCL filter grid-connected inverter using inverter-side current feedback
    Zheng Z.
    Huang X.
    Yang M.
    Gao L.
    Li B.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2019, 47 (19): : 31 - 37
  • [40] Robust control based on state observer applied to grid-connected converters
    Koch, Gustavo G.
    Maccari, Luiz A., Jr.
    Massing, Jorge R.
    Pinheiro, Humberto
    Oliveira, Ricardo C. L. F.
    Montagner, Vinicius F.
    2016 12TH IEEE/IAS INTERNATIONAL CONFERENCE ON INDUSTRY APPLICATIONS (INDUSCON), 2016,