Detection of Unicolor ECG Electrode Reversals in Standard 12-Lead ECG

被引:2
|
作者
Jekova, Irena [1 ]
Leber, Remo [2 ]
Krasteva, Vessela [1 ]
Schmid, Ramun [2 ]
机构
[1] Bulgarian Acad Sci, Inst Biophys & Biomed Engn, Acad G Bonchev Str,Bl 105, BU-1113 Sofia, Bulgaria
[2] Schiller AG, Signal Proc, Baar, Switzerland
关键词
AUTOMATIC DETECTION; LIMB-LEAD; MISPLACEMENT; ELECTROCARDIOGRAM; INTERCHANGE;
D O I
10.22489/CinC.2018.100
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This paper presents the performance of a commercial lead quality monitoring library (LQMLib, Schiller AG) for detection of reversals between 12-lead ECG cables with matching colors and proposes methods for improvements, where necessary. The study is performed on a large 12-lead ECG database with 1331 chest pain patients (646 training, 685 test recordings) and ECGs from 29 volunteers with swapped red, yellow, green, black and all unicolor cables. Relying on assessment of inter-lead correlations over continuous 4s episodes, LQMLib without adjustments achieves Se>97% for all unicolor cable reversals, except RC1 (Se=29%) and NC5 (Se=88%). The proposed additional analyses improve RC1 and NC5 swap detection by 63% points and 7% points, respectively.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Simulating Arbitrary Electrode Reversals in Standard 12-Lead ECG
    Krasteva, Vessela
    Jekova, Irena
    Schmid, Ramun
    SENSORS, 2019, 19 (13)
  • [2] A new 5 electrode 12-lead ECG (EASI) is equivalent to standard 12-lead ECG for myocardial infarction
    Wehr, G
    Peters, R
    Khalifé, K
    Banning, A
    Kuehlkamp, V
    Rickards, A
    Duller, B
    Sechtem, U
    INTENSIVE CARE MEDICINE, 2002, 28 : S78 - S78
  • [3] Use of the standard 12-lead ECG to simulate electrode displacements
    Schijvenaars, RJA
    Kors, JA
    vanHerpen, G
    vanBemmel, JH
    JOURNAL OF ELECTROCARDIOLOGY, 1996, 29 : 5 - 9
  • [4] COMPARISON OF INTRACORONARY ECG WITH STANDARD 12-LEAD ECG IN PTCA
    TATAMI, R
    YASUHARA, S
    YAMAMURA, M
    SHIBATA, K
    ISHISE, S
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1987, 51 (07): : 812 - 813
  • [5] Conversion of the ambulatory ECG to the standard 12-lead ECG: A preliminary study
    Zhu, X
    Yoshida, K
    Yamanobe, W
    Yamamoto, Y
    Chen, W
    Wei, D
    IEEE EMBS APBME 2003, 2003, : 48 - 49
  • [6] Investigation Of A Transfer Function Between Standard 12-Lead ECG And EASI ECG
    Oleksy, Wojciech
    Tkacz, Ewaryst
    ANALYSIS OF BIOMEDICAL SIGNALS AND IMAGES, 2010, : 322 - 327
  • [7] Effects of Electrode Misplacement on the Reconstruction of the 12-Lead ECG
    Finlay, D. D.
    Nelwan, S. P.
    Nugent, C. D.
    Meij, S. H.
    CINC: 2009 36TH ANNUAL COMPUTERS IN CARDIOLOGY CONFERENCE, 2009, 36 : 281 - +
  • [8] Detection of stable atrial fibrillation sources from standard 12-lead ECG
    Duchene, C.
    Lemay, M.
    Vesin, J. M.
    EUROPEAN HEART JOURNAL, 2009, 30 : 490 - 491
  • [9] Prehospital 12-lead ECG
    Joyce, SM
    ANNALS OF EMERGENCY MEDICINE, 1997, 30 (03) : 352 - 352
  • [10] Methodology for Automated Detection of Fragmentation in QRS complex of Standard 12-lead ECG
    Maheshwari, Sidharth
    Acharyya, Amit
    Puddu, Paolo Emilio
    Schiariti, Michele
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 3789 - 3792