Turbulent heat transfer enhancement by counter/co-swirling flow in a tube fitted with twin twisted tapes

被引:223
作者
Eiamsa-ard, S. [1 ]
Thianpong, C. [2 ]
Eiamsa-ard, P. [2 ]
机构
[1] Mahanakorn Univ Technol, Fac Engn, Dept Mech Engn, Bangkok 10530, Thailand
[2] King Mongkuts Inst Technol Ladkrabang, Fac Engn, Dept Mech Engn, Bangkok 10520, Thailand
关键词
Heat transfer; Friction factor; Enhancement index; Twin counter twisted tapes; Twin co-twisted tapes; FRICTION FACTOR CHARACTERISTICS; PRESSURE-DROP; LAMINAR-FLOW; ELEMENTS; PERFORMANCE; INSERTS;
D O I
10.1016/j.expthermflusci.2009.09.002
中图分类号
O414.1 [热力学];
学科分类号
摘要
In the present study, the influences of twin-counter/co-twisted tapes (counter/co-swirl tape) on heat transfer rate (Nu), friction factor (f) and thermal enhancement index (eta) are experimentally determined. The twin counter twisted tapes (CTs) are used as counter-swirl flow generators while twin co-twisted tapes (CoTs) are used as co-swirl flow generators in a test section. The tests are conducted using the CTs and CoTs with four different twist ratios (y/w=2.5, 3.0, 3.5 and 4.0) for Reynolds numbers range between 3700 and 21,000 under uniform heat flux conditions. The experiments using the single twisted tape (ST) are also performed under similar operation test conditions, for comparison. The experimental results demonstrate that Nusselt number (Nu), friction factor (f) and thermal enhancement index (eta) increase with decreasing twist ratio (y/w). The results also show that the CTs are more efficient than the CoTs for heat transfer enhancement. In the range of the present work, heat transfer rates in the tube fitted with the CTs are around 12.5-44.5% and 17.8-50% higher than those with the CoTs and ST, respectively. The maximum thermal enhancement indices (eta) obtained at the constant pumping power by the CTs with y/w = 2.5, 3.0, 3.5 and 4.0, are 1.39, 1.24, 1.12 and 1.03, respectively, while those obtained by using the CoTs with the same range of y/w are 1.1, 1.03, 0.97 and 0.92, respectively. In addition, the empirical correlations of the heat transfer (Nu), friction factor (f) and thermal enhancement index (eta) are also reported. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:53 / 62
页数:10
相关论文
共 20 条
  • [1] Heat transfer and pressure drop in a spirally grooved tube with twisted tape insert
    Bharadwaj, P.
    Khondge, A. D.
    Date, A. W.
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2009, 52 (7-8) : 1938 - 1944
  • [2] Heat transfer and friction correlations and thermal performance analysis for a finned surface
    Bilen, K
    Akyol, U
    Yapici, S
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2001, 42 (09) : 1071 - 1083
  • [3] Heat transfer and pressure drop in tube with broken twisted tape insert
    Chang, Shyy Woei
    Yang, Tsun Lirng
    Liou, Jin Shuen
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2007, 32 (02) : 489 - 501
  • [4] Turbulent heat transfer and pressure drop in tube fitted with serrated twisted tape
    Chang, Shyy Woei
    Jan, Yih Jena
    Liou, Jin Shuen
    [J]. INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2007, 46 (05) : 506 - 518
  • [5] Heat transfers in tubes fitted with single, twin, and triple twisted tapes
    Chang, SW
    Yu, KW
    Lu, MH
    [J]. EXPERIMENTAL HEAT TRANSFER, 2005, 18 (04) : 279 - 294
  • [6] DASMAHAPATRA JK, 1991, ASME HEAT TRANSFER D, V174, P51
  • [7] DEVELOPMENT OF CORRELATIONS FOR PREDICTING CHARACTERISTICS OF LAMINAR-FLOW IN A TUBE FITTED WITH REGULARLY SPACED TWISTED-TAPE ELEMENTS
    DATE, AW
    GAITONDE, UN
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 1990, 3 (04) : 373 - 382
  • [8] DEWAN A, 2004, J POWER ENERGY, V218, P509
  • [9] Experimental investigation of heat transfer and flow friction in a circular tube fitted with regularly spaced twisted tape elements
    Eiamsa-ard, Smith
    Thianpong, Chinaruk
    Promvonge, Pongjet
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2006, 33 (10) : 1225 - 1233
  • [10] EIAMSAARD S, INT COMMUNI IN PRESS