Retention of functional polymers in liquid adsorption chromatography: Effect of the end groups in PEGs and their methyl ethers in different mobile phases

被引:4
作者
Cuong, Nguyen V. [1 ]
Trathnigg, Bernd [1 ]
机构
[1] Karl Franzens Univ Graz, Inst Chem, CePol MC, A-8010 Graz, Austria
关键词
Interaction parameter; Liquid adsorption chromatography; Methyl ether; PEG; RP; REVERSED-PHASE; HOMOLOGOUS SERIES; INTERACTION PARAMETERS; DEAD VOLUME; TOPOLOGICAL SEPARATION; DATA-BASE; COLUMNS; MACROMOLECULES; TEMPERATURE; DEPENDENCE;
D O I
10.1002/jssc.200900685
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
It is shown that the end group parameter, which describes the influence of the end group on retention, can be determined in RP chromatography from two chromatograms of a nonfunctional and a monofunctional sample, if a sufficient number of peaks with the same number of repeat units in each sample can be reasonably resolved and identified. The same procedure can also be applied for pairs of di- and monofunctional polymers. End group parameters have been determined in three different mobile phases: acetonitrile water, acetone water and methanol water of different compositions. The temperature dependence of the interaction parameter of the repeat unit and the end group parameter has been found to be different, which allows a fine-tuning of retention.
引用
收藏
页码:1052 / 1057
页数:6
相关论文
共 35 条
[11]  
GORBUNOV AA, 1986, VYSOKOMOL SOEDIN A+, V28, P2170
[12]   Calibration of chromatographic systems for quantitative prediction of chromatography of homopolymers [J].
Gorbunov, Alexei A. ;
Vakhrushev, Andrey V. ;
Trathnigg, Bernd .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (51) :8883-8890
[13]   A theory of topological separation of linear and star-shaped polymers by two-dimensional chromatography [J].
Gorbunov, Alexei A. ;
Vakhrushev, Andrey V. .
POLYMER, 2009, 50 (12) :2727-2735
[14]   THERMODYNAMIC DEFINITION OF HPLC DEAD VOLUME [J].
KAZAKEVICH, YV ;
MCNAIR, HM .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1993, 31 (08) :317-322
[15]   Low-energy interactions in high-performance liquid chromatography [J].
Kazakevich, YV ;
McNair, HM .
JOURNAL OF CHROMATOGRAPHY A, 2000, 872 (1-2) :49-59
[16]   COMPARISON OF METHODS USED FOR THE DETERMINATION OF VOID VOLUME IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY [J].
KRSTULOVIC, AM ;
COLIN, H ;
GUIOCHON, G .
ANALYTICAL CHEMISTRY, 1982, 54 (14) :2438-2443
[17]   Microwave assisted synthesis and characterization of end functionalized poly(propylene oxide) as model compounds [J].
Malik, Muhammad Imran ;
Trathnigg, Bernd ;
Kappe, C. Oliver .
EUROPEAN POLYMER JOURNAL, 2008, 44 (01) :144-154
[18]  
Martin A.J.P., 1949, BIOCHEM SOC SYMP, V3, P4, DOI DOI 10.1002/JSSC.200900847
[19]   INFLUENCE OF TEMPERATURE ON DEAD VOLUME OF ODS COLUMNS AND ON N-ALKANE RETENTION IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
MOCKEL, HJ .
JOURNAL OF CHROMATOGRAPHY A, 1994, 675 (1-2) :13-28
[20]   Inorganic salts as hold-up time markers in C18 columns [J].
Oumada, FZ ;
Rosés, M ;
Bosch, E .
TALANTA, 2000, 53 (03) :667-677