Intraoperative Computed Tomography Image Fusion for Orbital Blowout Fracture Reconstruction

被引:3
|
作者
Nazimi, Abd Jabar [1 ]
Nabil, Syed [1 ]
机构
[1] Univ Kebangsaan Malaysia, Fac Dent, Dept Oral & Maxillofacial Surg, Kuala Lumpur 50300, Malaysia
来源
ARCHIVES OF OROFACIAL SCIENCE | 2021年 / 16卷 / 01期
关键词
Image fusion; implant malposition; intraoperative imaging; orbital blowout fracture; ZYGOMATICOMAXILLARY COMPLEX FRACTURES; ENOPHTHALMOS; FLOOR; MANAGEMENT; IMPLANTS; SURGERY; REPAIR;
D O I
10.21315/aos2021.16.1.1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Intraoperative computed tomography (CT) has been previously described and acknowledged for its use in orbital blowout fracture reconstructions. We described a clinical case series managed by this technique combined with intraoperative image fusion for accuracy in orbital implant position. In total, eight patients who sustained a total number of 19 orbital wall fractures were described. From the total number of 19 blowout orbital fracture reconstructions comprised of medial and inferior (floor) orbital fractures, malposition was identified in a total of four orbital implants by using image fusion. All cases of implant malposition were immediately revised intraoperatively. Subsequent fusion was carried out to confirm whether the revision was satisfactorily achieved. We found that the intraoperative image fusion technique utilised to determine orbital implant position, especially at the posterior ledge, further augmented the role of intraoperative CT scanning. Image fusion conceptually provides an immediate, real-time, and objective solution for intraoperative image analysis and potentially eliminates problems with misaligned CT images. It also reduces the need for the surgeon to 'eye-ball' the CT images acquired or the need for additional intraoperative time, since the patient's head orientation is always axially at random during the acquisition of the CT. Conventional methods for CT image assessment are subjected to one's own interpretation and may introduce inconsistent or longer intraoperative decision-making. The technique facilitates intraoperative decision-making and reduces the risk of orbital implant malposition in orbital blowout fracture reconstructions. Hence, surgical complication in relation to orbital implant malposition in orbital blowout fracture management could be minimised. In addition, no further postoperative imaging is required.
引用
收藏
页码:1 / 12
页数:12
相关论文
共 50 条
  • [31] Reconstruction of orbital blowout fractures using MEDPOR titanium mesh implants
    Han, Xiaohui
    Yang, Shunhai
    Dong, Zhizhang
    Feng, Wangqiang
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (06): : 12411 - 12415
  • [32] Simple Computed Tomography-Based Calculations of Orbital Floor Fracture Defect Size Are Not Sufficiently Accurate for Clinical Use
    Goggin, James
    Jupiter, Daniel C.
    Czerwinski, Marcin
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2015, 73 (01) : 112 - 116
  • [33] Orbital blowout fracture location in Japanese and Chinese patients
    Sun, Michelle T.
    Wu, Wencan
    Watanabe, Akihide
    Kakizaki, Hirohiko
    Chen, Ben
    Ueda, Kosuke
    Katori, Nobutada
    Takahashi, Yasuhiro
    Selva, Dinesh
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2015, 59 (01) : 65 - 69
  • [34] Orbital blowout fracture location in Japanese and Chinese patients
    Michelle T. Sun
    Wencan Wu
    Akihide Watanabe
    Hirohiko Kakizaki
    Ben Chen
    Kosuke Ueda
    Nobutada Katori
    Yasuhiro Takahashi
    Dinesh Selva
    Japanese Journal of Ophthalmology, 2015, 59 : 65 - 69
  • [35] ORBITAL BLOWOUT FRACTURE FROM HYDROSTATIC-PRESSURE
    RUBINSTEIN, C
    FERGUSON, A
    BROWN, P
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 1991, 61 (10): : 792 - 794
  • [36] Repair of blowout orbital floor fracture by periosteal suturing
    Noda, Mika
    Noda, Kousuke
    Ideta, Shinji
    Nakamura, Yasuhisa
    Ishida, Susumu
    Inoue, Makoto
    Tsubota, Kazuo
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 39 (04) : 364 - 369
  • [37] Outcomes of orbital blowout fracture surgery in children and adolescents
    Carroll, Stuart C.
    Ng, Stephen G. J.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2010, 94 (06) : 736 - 739
  • [38] Ageing increases risk of lower eyelid malposition after primary orbital fracture reconstruction
    Rajantie, Hanna
    Nikunen, Matti
    Raj, Rahul
    Snall, Johanna
    Thoren, Hanna
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2022, 60 (10) : 1391 - 1396
  • [39] Occult cancer detected by positron emission tomography/computed tomography image fusion
    Watanabe, SI
    Tanaka, D
    Nakamura, Y
    Kariatsumari, K
    Furumori, K
    Ohkubo, J
    Sakata, R
    Takagi, K
    ANTICANCER RESEARCH, 2005, 25 (1B) : 459 - 461
  • [40] Intelligent surgical planning for automatic reconstruction of orbital blowout fracture using a prior adversarial generative network
    Xu, Jiangchang
    Wei, Yining
    Jiang, Shuanglin
    Zhou, Huifang
    Li, Yinwei
    Chen, Xiaojun
    MEDICAL IMAGE ANALYSIS, 2025, 99