Improvement of Power System Stability by Using New Switching Technique in Bridge-type Fault Current Limiter

被引:25
作者
Firouzi, Mehdi [1 ]
Gharehpetian, Gevork Babamalek [2 ]
Mozafari, Babak [1 ]
机构
[1] Islamic Azad Univ, Sci & Res Branch, Dept Elect Engn, Tehran, Iran
[2] Amirkabir Univ Technol, Elect Engn Dept, Tehran, Iran
关键词
switching technique; power system stability; bridge-type fault current limiter; critical clearing time;
D O I
10.1080/15325008.2014.977463
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The bridge-type fault current limiter has the capability of controlling the fault current by controlling the DC reactor current. This fault current limiter is mainly composed of a diode bridge rectifier and a DC reactor. To achieve this capability, a resistor parallel with a semiconductor switch has been used in series with a DC reactor. For this fault current limiter, a control scheme is proposed that uses the DC reactor current as a control variable to improve transient stability of the model power system without measuring any parameters of system. In this article, an analytical and simulation study was conducted on a one-machine infinite-bus system including a bridge-type fault current limiter and the proposed control scheme. Simulation results show that by controlling the turn-on and turn-off times of the switch, i.e., the switching technique, the proposed fault current limiter can not only limit the fault current but also absorb the accelerating energy of the generator, thereby improving power system transient stability. The rotor velocity, maximum output power of the generator, and critical fault clearing time are studied in this article to evaluate the effects of the proposed fault current limiter on power system transient stability.
引用
收藏
页码:234 / 244
页数:11
相关论文
共 16 条
[1]  
[Anonymous], POWER SYSTEM STABILI
[2]   Test of resonance-type superconducting fault current limiter [J].
Arai, Kazuaki ;
Tanaka, Hideki ;
Inaba, Masaya ;
Arai, Hirohito ;
Ishigohka, Takeshi ;
Furuse, Mitsuho ;
Umeda, Masaichi .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2006, 16 (02) :650-653
[3]  
CIGRE, 2003, 239 CIGRE
[4]  
Firouzi M., 2012, EURO T ELECT POWER, P665
[5]   Experimental study on limiting operation of superconducting fault current limiter in double circuit transmission line model system [J].
Hatta, H ;
Muroya, S ;
Nitta, T ;
Shirai, Y ;
Taguchi, M .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2002, 12 (01) :812-815
[6]  
ISE T, 2001, IEEE T APPL SUPERCON, V11
[7]   Stability analysis of a power system with superconducting fault current limiter installed [J].
Lee, S ;
Lee, C ;
Ko, TK ;
Hyun, O .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2001, 11 (01) :2098-2101
[8]  
Lim M. S. H., 2006, IEEE T APPL SUPERCON, V16, P1932
[9]   Technical and economical benefits of superconducting fault current limiters in power systems [J].
Noe, M ;
Oswald, BR .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1999, 9 (02) :1347-1350
[10]  
Ro Lee E., 2002, IEEE T APPL SUPERCON, V12, P715