Indirect ultra-trace determination of nitrate and nitrite in food samples by in-syringe liquid microextraction and electrothermal atomic absorption spectrometry

被引:21
|
作者
Roohparvar, Rasool [1 ,2 ]
Shamspur, Tayebeh [1 ]
Mostafavi, Ali [1 ]
Bagheri, Habib [3 ]
机构
[1] Shahid Bahonar Univ, Dept Chem, Kerman, Iran
[2] Shahid Bahonar Univ Kerman, Young Res Soc, Kerman, Iran
[3] Sharif Univ Technol, Dept Chem, Environm & Bioanalyt Labs, Tehran, Iran
关键词
Liquid microextraction; Ion-pairing; Cu(I)-neocuproine; Nitrate; Nitrite; DIFFERENTIAL-PULSE POLAROGRAPHY; CLOUD-POINT EXTRACTION; SPECTROPHOTOMETRIC DETERMINATION; CAPILLARY-ELECTROPHORESIS; PHASE MICROEXTRACTION; DAIRY-PRODUCTS; PRECONCENTRATION; WATER; ION; QUANTIFICATION;
D O I
10.1016/j.microc.2018.06.027
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and rapid method for simultaneous separation and preconcentration of ultra-trace amounts of nitrate and nitrite using in-syringe liquid microextraction is developed. The extraction procedure is based on the selective ion-pairing complex formation of nitrate and nitrite with Cu(I)-neocuproine in 100 mu L of 1-butyl-3-methylimidazolium hexafluorophosphate as an extracting phase within a syringe. The atomic-absorption signal of copper in the ionic liquid layer is proportional to the nitrate and nitrite concentrations. When barbituric acid is used, nitrite is converted into violuric acid and thus it is removed from the environment. In this case, the selectivity of the modified-ligand is limited to nitrate. Under optimum experimental conditions, the calibration graph was in the range from 0.1 to 25 mu g L-1 for nitrate and 0.05 to 10 mu g L-1 for nitrite, respectively. The detection limits for these two anions were around 0.013 mu g L-1. The resultant repeatability expressed as relative standard deviations (RSDs, n = 6) was < 5.1%. The accuracy of the proposed method was confirmed using addition/recovery test and analyzing with the reference method. At two different addition levels for each analyte, recoveries were determined to be within the range from 94.2 to 103.3% for nitrate and 93.4 to 98.2% for nitrite, respectively. There was also no significant difference between the results when t-test is used with 95% confidence (n = 6). The applicability of the method was extended to the extraction and preconcentration of nitrate and nitrite from tuna fish, tomato paste and infant food sample.
引用
收藏
页码:135 / 139
页数:5
相关论文
共 50 条
  • [31] Ultra-trace determination of silver in water samples by electrothermal atomic absorption spectrometry after preconcentration with a ligand-less cloud point extraction methodology
    Manzoori, Jamshid L.
    Abdolmohammad-Zadeh, Hossein
    Amjadi, Mohammad
    JOURNAL OF HAZARDOUS MATERIALS, 2007, 144 (1-2) : 458 - 463
  • [32] Ionic liquid-based single drop microextraction combined with electrothermal atomic absorption spectrometry for the determination of manganese in water samples
    Manzoori, Jamshid L.
    Amjadi, Mohammad
    Abulhassani, Jafar
    TALANTA, 2009, 77 (04) : 1539 - 1544
  • [33] Application of microwave-assisted dispersive liquid-liquid microextraction and graphite furnace atomic absorption spectrometry for ultra-trace determination of lead and cadmium in cereals and agricultural products
    Ataee, Mari
    Ahmadi-Jouibari, Toraj
    Fattahi, Nazir
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2016, 96 (03) : 271 - 283
  • [34] Hollow fiber based liquid-phase microextraction for the determination of mercury traces in water samples by electrothermal atomic absorption spectrometry
    Lopez-Garcia, Ignacio
    Rivas, Ricardo E.
    Hernandez-Cordoba, Manuel
    ANALYTICA CHIMICA ACTA, 2012, 743 : 69 - 74
  • [35] A novel strategy based on in-syringe dispersive liquid-liquid microextraction for the determination of nickel in chocolate samples
    Barreto, Jeferson Alves
    de Assis, Rosivan dos Santos
    Cassella, Ricardo Jorgensen
    Lemos, Valfredo Azevedo
    TALANTA, 2019, 193 : 23 - 28
  • [36] In-situ suspended aggregate microextraction of gold nanoparticles from water samples and determination by electrothermal atomic absorption spectrometry
    Choleva, Tatiana G.
    Kappi, Foteini A.
    Tsogas, George Z.
    Vlessidis, Athanasios G.
    Giokas, Dimosthenis L.
    TALANTA, 2016, 151 : 91 - 99
  • [37] Solidified floating organic drop microextraction-electrothermal atomic absorption spectrometry for ultra trace determination of antimony species in tea, basil and water samples
    Dadfarnia, Shayessteh
    Shabani, Ali Mohammad Haji
    Abadi, Maryam Nili Ahmad
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2013, 10 (02) : 289 - 296
  • [38] Fluorescence enhancement of rhodamine B as a tool for the determination of trace and ultra-trace concentrations of bismuth using dispersive liquid-liquid microextraction
    Al-Saidi, H. M.
    El-Bindary, A. A.
    El-Sonbati, A. Z.
    Abdel-Fadeel, M. A.
    RSC ADVANCES, 2016, 6 (25) : 21210 - 21218
  • [39] Ligandless dispersive liquid-liquid microextraction combined with syringe to syringe back extraction for the determination of lead in water samples by flame atomic absorption spectrometry
    Yao, Li
    Xu, Wenzhi
    Lin, Chaowen
    Zhu, Yongqun
    Luo, Fuxiang
    Zhang, Jianhua
    Liu, Haitao
    Pang, Liangyu
    ANALYTICAL METHODS, 2017, 9 (32) : 4673 - 4679
  • [40] Ligandless Dispersive Liquid-Liquid Microextraction of Iron in Biological and Foodstuff Samples and Its Determination by Electrothermal Atomic Absorption Spectrometry
    Madadizadeh, Mohadeseh
    Taher, Mohammad Ali
    Ashkenani, Hamid
    JOURNAL OF AOAC INTERNATIONAL, 2013, 96 (06) : 1466 - 1472