Influence of tidal volume on left ventricular stroke volume variation measured by pulse contour analysis in mechanically ventilated patients

被引:211
作者
Reuter, DA
Bayerlein, J
Goepfert, MSG
Weis, FC
Kilger, E
Lamm, P
Goetz, AE
机构
[1] Univ Munich, Dept Anesthesiol, D-81377 Munich, Germany
[2] Univ Munich, Dept Cardiac Surg, D-81377 Munich, Germany
关键词
diagnostic techniques; cardiovascular; preload; fluid responsiveness; cardiac output; pulse contour analysis; mechanical ventilation;
D O I
10.1007/s00134-003-1649-7
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Real-time measurement of stroke volume variation by arterial pulse contour analysis (SVV) is useful in predicting volume responsiveness and monitoring volume therapy in mechanically ventilated patients. This study investigated the influence of the depth of tidal volume (V-t) on SVV both during the state of fluid responsiveness and after fluid loading in mechanically ventilated patients. Design and setting: Prospective study in a university hospital, adult cardiac surgery intensive care unit. Patients and participants: 20 hemodynamically stable patients immediately after cardiac surgery. Interventions: Stepwise fluid loading using colloids until stroke volume index (SVI) did not increase by more than 10%. Before and after fluid loading V-t was varied (5, 10, and 15 ml/kg body weight) in random order. Measurements and results: Pulse contour SVV was measured before and after volume loading at the respective V-t values. Thirteen patients responded to fluid loading with an increase in SVI greater than 10%, which confirmed volume responsiveness at baseline measurements. These were included in further analysis. During volume responsiveness SVV at V-t of 5 ml/kg (7+/-0.7%) and SVV at V-t of 15 ml/kg (21+/-2.5%) differed significantly from that at V-t of 10 ml/kg (15+/-2.1%). SVV was correlated significantly with the magnitude of V-t. After volume resuscitation SVV at the respective V-t was significantly reduced; further, SVV at V-t of 5 ml/kg(-1) (5.3+/-0.6%) and 15 ml/kg (16.2+/-2.0%) differed significantly from that at V-t of 10 ml/kg (10.2+/-1.0%). SVV and depth of V-t were significantly related. Conclusions: In addition to intravascular volume status SVV is affected by the depth of tidal volume under mechanical ventilation. This influence must be regarded when using SVV for functional preload monitoring.
引用
收藏
页码:476 / 480
页数:5
相关论文
共 50 条
  • [41] Effective evaluation of arterial pulse waveform analysis by two-dimensional stroke volume variation-stroke volume index plots
    Sawa, Teiji
    Kinoshita, Mao
    Kainuma, Atsushi
    Akiyama, Koichi
    Naito, Yoshifumi
    Kato, Hideya
    Amaya, Fumimasa
    Shigemi, Keiji
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2017, 31 (05) : 927 - 941
  • [42] Incorporating pulse wave velocity into model-based pulse contour analysis method for estimation of cardiac stroke volume
    Smith, Rachel
    Balmer, Joel
    Pretty, Christopher G.
    Mehta-Wilson, Tashana
    Desaive, Thomas
    Shaw, Geoffrey M.
    Chase, J. Geoffrey
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2020, 195
  • [43] The Accuracy of Velocity-Time Integral Variation and Peak Velocity Variation of the Left Ventricular Outflow Tract in Predicting Fluid Responsiveness in Postoperative Patients Mechanically Ventilated at Low Tidal Volumes
    Xie, Jin
    Wan, Jingjie
    Xu, Li
    Zhang, Yukun
    Chen, Jun
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2023, 37 (06) : 911 - 918
  • [44] Usefulness of left ventricular stroke volume variation to assess fluid responsiveness in patients with reduced cardiac function
    Reuter, DA
    Kirchner, A
    Felbinger, TW
    Weis, FC
    Kilger, E
    Lamm, P
    Goetz, AE
    CRITICAL CARE MEDICINE, 2003, 31 (05) : 1399 - 1404
  • [45] Accuracy of stroke volume variation compared with pleth variability index to predict fluid responsiveness in mechanically ventilated patients undergoing major surgery
    Zimmermann, Markus
    Feibicke, Thomas
    Keyl, Cornelius
    Prasser, Christopher
    Moritz, Stefan
    Graf, Bernhard M.
    Wiesenack, Christoph
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (06) : 555 - 561
  • [46] Stroke volume variation and pulse pressure variation measured at pulmonary arterial level versus pulse pressure variation measured at systemic arterial level: an exploratory study
    Slabbaert, M.
    Vandenheuvel, M.
    Wouters, P.
    ACTA ANAESTHESIOLOGICA BELGICA, 2021, 72 : 235 - 244
  • [47] Influence of increased intra-abdominal pressure on fluid responsiveness predicted by pulse pressure variation and stroke volume variation in a porcine model
    Renner, Jochen
    Gruenewald, Matthias
    Quaden, Rene
    Hanss, Robert
    Meybohm, Patrick
    Steinfath, Markus
    Scholz, Jens
    Bein, Berthold
    CRITICAL CARE MEDICINE, 2009, 37 (02) : 650 - 658
  • [48] Diagnostic accuracy of stroke volume variation measured with uncalibrated arterial waveform analysis for the prediction of fluid responsiveness in patients with impaired left ventricular function: a prospective, observational study
    Montenij, L. J.
    Sonneveld, J. P. C.
    Nierich, A. P.
    Buhre, W. F.
    de Waal, E. E. C.
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2016, 30 (04) : 481 - 486
  • [49] Effect of pulse pressure on the predictability of stroke volume variation for fluid responsiveness in patients with coronary disease
    Kim, So Yeon
    Song, Young
    Shim, Jae Kwang
    Kwak, Young Lan
    JOURNAL OF CRITICAL CARE, 2013, 28 (03) : 318.e1 - 318.e7
  • [50] Effective evaluation of arterial pulse waveform analysis by two-dimensional stroke volume variation–stroke volume index plots
    Teiji Sawa
    Mao Kinoshita
    Atsushi Kainuma
    Koichi Akiyama
    Yoshifumi Naito
    Hideya Kato
    Fumimasa Amaya
    Keiji Shigemi
    Journal of Clinical Monitoring and Computing, 2017, 31 : 927 - 941