Influence of tidal volume on left ventricular stroke volume variation measured by pulse contour analysis in mechanically ventilated patients

被引:211
作者
Reuter, DA
Bayerlein, J
Goepfert, MSG
Weis, FC
Kilger, E
Lamm, P
Goetz, AE
机构
[1] Univ Munich, Dept Anesthesiol, D-81377 Munich, Germany
[2] Univ Munich, Dept Cardiac Surg, D-81377 Munich, Germany
关键词
diagnostic techniques; cardiovascular; preload; fluid responsiveness; cardiac output; pulse contour analysis; mechanical ventilation;
D O I
10.1007/s00134-003-1649-7
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Real-time measurement of stroke volume variation by arterial pulse contour analysis (SVV) is useful in predicting volume responsiveness and monitoring volume therapy in mechanically ventilated patients. This study investigated the influence of the depth of tidal volume (V-t) on SVV both during the state of fluid responsiveness and after fluid loading in mechanically ventilated patients. Design and setting: Prospective study in a university hospital, adult cardiac surgery intensive care unit. Patients and participants: 20 hemodynamically stable patients immediately after cardiac surgery. Interventions: Stepwise fluid loading using colloids until stroke volume index (SVI) did not increase by more than 10%. Before and after fluid loading V-t was varied (5, 10, and 15 ml/kg body weight) in random order. Measurements and results: Pulse contour SVV was measured before and after volume loading at the respective V-t values. Thirteen patients responded to fluid loading with an increase in SVI greater than 10%, which confirmed volume responsiveness at baseline measurements. These were included in further analysis. During volume responsiveness SVV at V-t of 5 ml/kg (7+/-0.7%) and SVV at V-t of 15 ml/kg (21+/-2.5%) differed significantly from that at V-t of 10 ml/kg (15+/-2.1%). SVV was correlated significantly with the magnitude of V-t. After volume resuscitation SVV at the respective V-t was significantly reduced; further, SVV at V-t of 5 ml/kg(-1) (5.3+/-0.6%) and 15 ml/kg (16.2+/-2.0%) differed significantly from that at V-t of 10 ml/kg (10.2+/-1.0%). SVV and depth of V-t were significantly related. Conclusions: In addition to intravascular volume status SVV is affected by the depth of tidal volume under mechanical ventilation. This influence must be regarded when using SVV for functional preload monitoring.
引用
收藏
页码:476 / 480
页数:5
相关论文
共 50 条
  • [31] Stroke Volume Variation Derived by Arterial Pulse Contour Analysis Is a Good Indicator for Preload Estimation During Liver Transplantation
    Su, B. C.
    Tsai, Y. F.
    Cheng, C. W.
    Yu, H. P.
    Yang, M. W.
    Lee, W. C.
    Lin, C. C.
    TRANSPLANTATION PROCEEDINGS, 2012, 44 (02) : 429 - 432
  • [32] Influence of tidal volume for stroke volume variation to predict fluid responsiveness in patients undergoing one-lung ventilation
    Koichi Suehiro
    Ryu Okutani
    Journal of Anesthesia, 2011, 25 : 777 - 780
  • [33] Evaluation of stroke volume variation obtained by arterial pulse contour analysis to predict fluid responsiveness intraoperatively
    Lahner, D.
    Kabon, B.
    Marschalek, C.
    Chiari, A.
    Pestel, G.
    Kaider, A.
    Fleischmann, E.
    Hetz, H.
    BRITISH JOURNAL OF ANAESTHESIA, 2009, 103 (03) : 346 - 351
  • [34] Using pulse pressure variation or stroke volume variation to diagnose right ventricular failure?
    Frederic Michard
    Guy Richards
    Matthieu Biais
    Marcel Lopes
    Jose Otavio Auler
    Critical Care, 14
  • [35] Using pulse pressure variation or stroke volume variation to diagnose right ventricular failure?
    Michard, Frederic
    Richards, Guy
    Biais, Matthieu
    Lopes, Marcel
    Auler, Jose Otavio
    CRITICAL CARE, 2010, 14 (06):
  • [36] Agreement between stroke volume measured by oesophageal Doppler and uncalibrated pulse contour analysis during fluid loads in severe aortic stenosis
    Lars Øivind Høiseth
    Ingrid Elise Hoff
    Ove Andreas Hagen
    Svein Aslak Landsverk
    Knut Arvid Kirkebøen
    Journal of Clinical Monitoring and Computing, 2015, 29 : 435 - 441
  • [37] Changes in pulse pressure variation induced by passive leg raising test to predict preload responsiveness in mechanically ventilated patients with low tidal volume in ICU: a systematic review and meta-analysis
    Mallat, Jihad
    Siuba, Matthew T.
    Abou-Arab, Osama
    Kovacevic, Pedja
    Ismail, Khaled
    Duggal, Abhijit
    Guinot, Pierre-Gregoire
    CRITICAL CARE, 2025, 29 (01) : 18
  • [38] Comparative evaluation of stroke volume variation and inferior vena cava distensibility index for prediction of fluid responsiveness in mechanically ventilated patients
    Kaur, Kaminder Bir
    Nakra, Monish
    Mangal, Vishal
    Singh, Shalendra
    Taank, Priya
    Marwah, Vikas
    ANNALS OF CARDIAC ANAESTHESIA, 2021, 24 (03) : 327 - 332
  • [39] Tidal Volume and Mortality in Mechanically Ventilated Children: A Systematic Review and Meta-Analysis of Observational Studies
    de Jager, Pauline
    Burgerhof, Johannes G. M.
    van Heerde, Marc
    Albers, Marcel J. I. J.
    Markhorst, Dick G.
    Kneyber, Martin C. J.
    CRITICAL CARE MEDICINE, 2014, 42 (12) : 2461 - 2472
  • [40] Pulse pressure variation shows a direct linear correlation with tidal volume in anesthetized healthy patients
    Liu, Yi
    Lou, Jing-sheng
    Mi, Wei-dong
    Yuan, Wei-xiu
    Fu, Qiang
    Wang, Min
    Qu, Jing
    BMC ANESTHESIOLOGY, 2016, 16