Quantitative analysis of curcumin-loaded alginate nanocarriers in hydrogels using Raman and attenuated total reflection infrared spectroscopy

被引:20
|
作者
Miloudi, Lynda [1 ]
Bonnier, Franck [1 ]
Bertrand, Dominique [2 ]
Byrne, Hugh J. [3 ]
Perse, Xavier [1 ]
Chourpa, Igor [1 ]
Munnier, Emilie [1 ]
机构
[1] Univ Francois Rabelais Tours, EA Nanomedicaments & Nanosondes 6295, 31 Ave Monge, F-37200 Tours, France
[2] Data Frame, 25 Rue Stendhal, F-44300 Nantes, France
[3] DIT, FOCAS Res Inst, Dublin 8, Ireland
关键词
Infrared spectroscopy; Raman spectroscopy; Curcumin-loaded alginate nanocarriers (C_ANC); Hydrogel; Aqueous solutions; Partial least square regression (PLSR); VIBRATIONAL SPECTROSCOPY; IN-VITRO; GEL; DELIVERY; CARRIER; QUANTIFICATION; NANOPARTICLES; RELEASE; SYSTEM; NANOTECHNOLOGY;
D O I
10.1007/s00216-017-0402-y
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Core-shell nanocarriers are increasingly being adapted in cosmetic and dermatological fields, aiming to provide an increased penetration of the active pharmaceutical or cosmetic ingredients (API and ACI) through the skin. In the final form, the nanocarriers (NC) are usually prepared in hydrogels, conferring desired viscous properties for topical application. Combined with the high chemical complexity of the encapsulating system itself, involving numerous ingredients to form a stable core and quantifying the NC and/or the encapsulated active without labor-intensive and destructive methods remains challenging. In this respect, the specific molecular fingerprint obtained from vibrational spectroscopy analysis could unambiguously overcome current obstacles in the development of fast and cost-effective quality control tools for NC-based products. The present study demonstrates the feasibility to deliver accurate quantification of the concentrations of curcumin (ACI)-loaded alginate nanocarriers in hydrogel matrices, coupling partial least square regression (PLSR) to infrared (IR) absorption and Raman spectroscopic analyses. With respective root mean square errors of 0.1469 +/- A 0.0175% w/w and 0.4462 +/- A 0.0631% w/w, both approaches offer acceptable precision. Further investigation of the PLSR results allowed to highlight the different selectivity of each approach, indicating only IR analysis delivers direct monitoring of the NC through the quantification of the LabrafacA (R), the main NC ingredient. Raman analyses are rather dominated by the contribution of the ACI which opens numerous perspectives to quantify the active molecules without interferences from the complex core-shell encapsulating systems thus positioning the technique as a powerful analytical tool for industrial screening of cosmetic and pharmaceutical products.
引用
收藏
页码:4593 / 4605
页数:13
相关论文
共 50 条
  • [31] Fatty Acid Determination in Human Milk Using Attenuated Total Reflection Infrared Spectroscopy and Solvent-Free Lipid Separation
    Akhgar, Christopher K.
    Nuernberger, Vanessa
    Nadvornik, Marlene
    Ramos-Garcia, Victoria
    Ten-Domenech, Isabel
    Kuligowski, Julia
    Schwaighofer, Andreas
    Rosenberg, Erwin
    Lendl, Bernhard
    APPLIED SPECTROSCOPY, 2022, 76 (06) : 730 - 736
  • [32] Diagnosis and monitoring of hepatocellular carcinoma in Hepatitis C virus patients using attenuated total reflection Fourier transform infrared spectroscopy
    Ali, Salmann
    Naveed, Ammara
    Hussain, Irshad
    Qazi, Javaria
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2023, 43
  • [33] Experiments on adsorption at hydrous metal oxide surfaces using attenuated total reflection infrared spectroscopy (ATRIRS) (IUPAC Technical Report)
    McQuillan, A. James
    Osawa, Masatoshi
    Peak, Derek
    Ren, Bin
    Tian, Zhong-Qun
    PURE AND APPLIED CHEMISTRY, 2019, 91 (12) : 2043 - 2061
  • [34] Study of Victorian Brown Coal Dewatering by Super Absorbent Polymers using Attenuated Total Reflection Fourier Transform Infrared Spectroscopy
    Devasahayam, Sheila
    Bandyopadhyay, Sri
    Hill, David J. T.
    MINERAL PROCESSING AND EXTRACTIVE METALLURGY REVIEW, 2016, 37 (04): : 220 - 226
  • [35] Quantitative detection of aqueous arsenic and other oxoanions using attenuated total reflectance infrared spectroscopy utilizing iron oxide coated internal reflection elements to enhance the limits of detection
    McAuley, B.
    Cabaniss, S. E.
    ANALYTICA CHIMICA ACTA, 2007, 581 (02) : 309 - 317
  • [36] Discerning Some Tylenol Brands Using Attenuated Total Reflection Fourier Transform Infrared Data and Multivariate Analysis Techniques
    Msimanga, Huggins Z.
    Ollis, Robert J., Jr.
    APPLIED SPECTROSCOPY, 2010, 64 (06) : 657 - 668
  • [37] Validated Approaches for Quantification of Bone Mineral Crystallinity Using Transmission Fourier Transform Infrared (FT-IR), Attenuated Total Reflection (ATR) FT-IR, and Raman Spectroscopy
    Querido, William
    Ailavajhala, Ramyasri
    Padalkar, Mugdha
    Pleshko, Nancy
    APPLIED SPECTROSCOPY, 2018, 72 (11) : 1581 - 1593
  • [38] Mesoporous Zirconia Coating for Sensing Applications Using Attenuated Total Reflection Fourier Transform Infrared (ATR FT-IR) Spectroscopy
    Wacht, Dominik
    David, Mauro
    Hinkov, Borislav
    Detz, Hermann
    Schwaighofer, Andreas
    Baumgartner, Bettina
    Lendl, Bernhard
    APPLIED SPECTROSCOPY, 2022, 76 (01) : 141 - 149
  • [39] Attenuated total reflection infrared spectroscopy for micro-domain analysis of polyethylene samples after accelerated ageing within weathering chambers
    Küpper, L
    Gulmine, JV
    Janissek, PR
    Heise, HM
    VIBRATIONAL SPECTROSCOPY, 2004, 34 (01) : 63 - 72
  • [40] Unfrazzled by Fizziness: Identification of Beers Using Attenuated Total Reflectance Mid-infrared Spectroscopy and Multivariate Analysis
    Gordon, Russell
    Chapman, James
    Power, Aoife
    Chandra, Shaneel
    Roberts, Jessica
    Cozzolino, Daniel
    FOOD ANALYTICAL METHODS, 2018, 11 (09) : 2360 - 2367