Stress analysis of total hip arthroplasty with a fully hydroxyapatite-coated stem: comparing thermoelastic stress analysis and CT-based finite element analysis

被引:2
作者
Watanabe, Ryunosuke [1 ]
Mishima, Hajime [1 ]
Takehashi, Hironori [1 ]
Wada, Hiroshi [1 ]
Totsuka, Sho [1 ]
Nishino, Tomofumi [1 ]
Yamazaki, Masashi [1 ]
Hyodo, Koji
机构
[1] Univ Tsukuba, Fac Med, Dept Orthopaed Surg, Tsukuba, Japan
关键词
total hip arthroplasty; thermoelastic stress analysis; computed tomography-based finite element analysis; fully hydroxyapatite-coated stem; femoral stress distribution; STRUCTURAL-PROPERTIES; STRAIN DISTRIBUTION; FEMORAL STEM; LONG-TERM; REPLACEMENT; INSERTION; STANDARD; MIDTERM; DESIGN; FEMURS;
D O I
10.37190/ABB-01994-2021-01
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Purpose The aim of this study was to evaluate the stress distribution in a synthetic femur that was implanted with a fully hydroxyapatite-coated stem using thermoelastic stress and finite element analyses, and to clarify the differences in the stress distributions between these two methods. Methods Thermoelastic stress analysis is a stress-analysis technique that employs the thermoelastic effect. Sinusoidal vertical loads were applied to the head of the stern placed on the synthetic femur, and surface stress distribution images were acquired using an infrared stress measurement system. The finite element model for the synthetic femur and stem were set up similar to the thermoelastic stress analysis experiment and vertical load was applied to the head of the stem. Surface stress distribution and stress values obtained via these two methods were compared. Results Thermoelastic stress analysis showed that compressive and tensile stresses were distributed from the proximal femur to the diaphysis, not only on the medial and lateral surfaces, but also on the anterior and posterior surfaces. However, finite element analysis showed that compressive stress was not distributed on the anterior and posterior surfaces of the femoral intertrochanter. The stress values of therm oelastic stress analysis tended to be higher in the proximal femur than that obtained via the finite element analysis. Conclusions The surface stress distribution obtained by these two methods were different specifically in the proximal femur. Our results imply that thermoelastic stress analysis has a better potential than finite element analysis to show the surface stress distribution that reflects the stem design.
引用
收藏
页数:20
相关论文
共 31 条
[1]   Changes in proximal femoral strain after insertion of uncemented standard and customised femoral stems [J].
Aamodt, A ;
Lund-Larsen, J ;
Eine, J ;
Andersen, E ;
Benum, P ;
Husby, OS .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (06) :921-929
[2]  
[Anonymous], 2020, The National Joint Registry 17th Annual Report 2020
[3]   Mid-term clinical results of the cementless R3 cup and Polarstem total hip arthroplasty [J].
Assaf, Ali ;
Manara, Jonathan R. ;
Teoh, Kar H. ;
Evans, Aled R. .
EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2019, 29 (04) :827-833
[4]   Primary stability and strain distribution of cementless hip stems as a function of implant design [J].
Bieger, Ralf ;
Ignatius, Anita ;
Decking, Ralf ;
Claes, Lutz ;
Reichel, Heiko ;
Duerselen, Lutz .
CLINICAL BIOMECHANICS, 2012, 27 (02) :158-164
[5]   Stress analysis of a carbon fiber-reinforced epoxy plate with a hole undergoing tension: A comparison of finite element analysis, strain gages, and infrared thermography [J].
Bougherara, Habiba ;
Saleem, Muhammad ;
Shah, Suraj ;
Toubal, Lotfi ;
Sarwar, Ahmed ;
Schemitsch, Emil H. ;
Zdero, Radovan .
JOURNAL OF COMPOSITE MATERIALS, 2018, 52 (19) :2679-2689
[6]   A NOVEL METHOD FOR THE DESIGN OF PROSTHESES BASED ON THERMOELASTIC STRESS ANALYSIS AND FINITE ELEMENT ANALYSIS [J].
Cannella, Ferdinando ;
Garinei, Alberto ;
D'Imperio, Mariapaola ;
Rossi, Gianluca .
JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2014, 14 (05)
[7]   Long-term outcomes of a dual-mobility cup and cementless triple-taper femoral stem combination in total hip replacement: a multicenter retrospective analysis [J].
Cypres, Alain ;
Fiquet, Arnaud ;
Girardin, Philippe ;
Fitch, David ;
Bauchu, Philippe ;
Bonnard, Olivier ;
Noyer, Daniel ;
Roy, Christophe .
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2019, 14 (01)
[8]   POROUS-COATED HIP-REPLACEMENT - THE FACTORS GOVERNING BONE INGROWTH, STRESS SHIELDING, AND CLINICAL-RESULTS [J].
ENGH, CA ;
BOBYN, JD ;
GLASSMAN, AH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1987, 69 (01) :45-55
[9]   A short stem with metaphyseal anchorage reveals a more physiological strain pattern compared to a standard stem - an experimental study in cadavaric bone [J].
Floerkemeier, Thilo ;
Weltin, Jennifer ;
Budde, Stefan ;
Hurschler, Christof ;
Windhagen, Henning ;
von Lewinski, Gabriela ;
Gronewold, Jens .
ACTA OF BIOENGINEERING AND BIOMECHANICS, 2019, 21 (02) :153-159
[10]   Structural properties of a new design of composite replicate femurs and tibias [J].
Heiner, AD ;
Brown, TD .
JOURNAL OF BIOMECHANICS, 2001, 34 (06) :773-781