Potentialities of High-Resolution 3-D CZT Drift Strip Detectors for Prompt Gamma-Ray Measurements in BNCT

被引:15
|
作者
Abbene, Leonardo [1 ]
Principato, Fabio [1 ]
Buttacavoli, Antonino [1 ]
Gerardi, Gaetano [1 ]
Bettelli, Manuele [2 ]
Zappettini, Andrea [2 ]
Altieri, Saverio [3 ,4 ]
Auricchio, Natalia [5 ]
Caroli, Ezio [5 ]
Zanettini, Silvia [6 ]
Protti, Nicoletta [3 ,4 ]
机构
[1] Univ Palermo, Dept Phys & Chem DiFC Emilio Segre, Viale Sci,Edificio 18, I-90128 Palermo, Italy
[2] CNR, IMEM, Parco Area Sci 37-A, I-43100 Parma, Italy
[3] Univ Pavia, Dept Phys, Via Agostino Bassi 6, I-27100 Pavia, Italy
[4] Nucl Phys Natl Inst INFN, Unit Pavia, Via Agostino Bassi 6, I-27100 Pavia, Italy
[5] OAS Bologna, INAF, I-40129 Bologna, Italy
[6] Due2lab srl, Via Paolo Borsellino 2, I-42019 Scandiano, Italy
关键词
CZT detectors; X-ray and gamma-ray detectors; BNCT; NEUTRON-CAPTURE THERAPY; THICK CDTE DETECTOR; COMPTON CAMERA; PG-SPECT; SYSTEM; ARRAYS;
D O I
10.3390/s22041502
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Recently, new high-resolution cadmium-zinc-telluride (CZT) drift strip detectors for room temperature gamma-ray spectroscopic imaging were developed by our group. The CZT detectors equipped with orthogonal anode/cathode collecting strips, drift strips and dedicated pulse processing allow a detection area of 6 x 20 mm(2) and excellent room temperature spectroscopic performance (0.82% FWHM at 661.7 keV). In this work, we investigated the potentialities of these detectors for prompt gamma-ray spectroscopy (PGS) in boron neutron capture therapy (BNCT). The detectors, exploiting the measurement of the 478 keV prompt gamma rays emitted by 94% Li-7 nuclides from the B-10(n, alpha)Li-7 reaction, are very appealing for the development of single-photon emission computed tomography (SPECT) systems and Compton cameras in BNCT. High-resolution gamma-ray spectra from B-10 samples under thermal neutrons were measured at the T.R.I.G.A. Mark II research nuclear reactor of the University of Pavia (Italy).
引用
收藏
页数:11
相关论文
共 23 条
  • [21] High-Resolution X-Ray CT for 3D Petrography of Ferruginous Sandstone for an Investigation of Building Stone Decay
    Cnudde, Veerle
    Dewanckele, Jan
    Boone, Matthieu
    de Kock, Tim
    Boone, Marijn
    Brabant, Loes
    Dusar, Michiel
    de Ceukelaire, Marleen
    de Clercq, Hilde
    Hayen, Roald
    Jacobs, Patric
    MICROSCOPY RESEARCH AND TECHNIQUE, 2011, 74 (11) : 1006 - 1017
  • [22] High-Resolution Real-Time Underwater 3-D Acoustical Imaging Through Designing Ultralarge Ultrasparse Ultra-Wideband 2-D Arrays
    Chi, Cheng
    Li, Zhaohui
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2017, 66 (10) : 2647 - 2657
  • [23] High-resolution spatial rupture pattern of a multiphase flower structure, Rex Hills, Nevada: New insights on scarp evolution in complex topography based on 3-D laser scanning
    Baran, Ramona
    Guest, Bernard
    Friedrich, Anke M.
    GEOLOGICAL SOCIETY OF AMERICA BULLETIN, 2010, 122 (5-6) : 897 - 914