Potentialities of High-Resolution 3-D CZT Drift Strip Detectors for Prompt Gamma-Ray Measurements in BNCT

被引:17
作者
Abbene, Leonardo [1 ]
Principato, Fabio [1 ]
Buttacavoli, Antonino [1 ]
Gerardi, Gaetano [1 ]
Bettelli, Manuele [2 ]
Zappettini, Andrea [2 ]
Altieri, Saverio [3 ,4 ]
Auricchio, Natalia [5 ]
Caroli, Ezio [5 ]
Zanettini, Silvia [6 ]
Protti, Nicoletta [3 ,4 ]
机构
[1] Univ Palermo, Dept Phys & Chem DiFC Emilio Segre, Viale Sci,Edificio 18, I-90128 Palermo, Italy
[2] CNR, IMEM, Parco Area Sci 37-A, I-43100 Parma, Italy
[3] Univ Pavia, Dept Phys, Via Agostino Bassi 6, I-27100 Pavia, Italy
[4] Nucl Phys Natl Inst INFN, Unit Pavia, Via Agostino Bassi 6, I-27100 Pavia, Italy
[5] OAS Bologna, INAF, I-40129 Bologna, Italy
[6] Due2lab srl, Via Paolo Borsellino 2, I-42019 Scandiano, Italy
关键词
CZT detectors; X-ray and gamma-ray detectors; BNCT; NEUTRON-CAPTURE THERAPY; THICK CDTE DETECTOR; COMPTON CAMERA; PG-SPECT; SYSTEM; ARRAYS;
D O I
10.3390/s22041502
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Recently, new high-resolution cadmium-zinc-telluride (CZT) drift strip detectors for room temperature gamma-ray spectroscopic imaging were developed by our group. The CZT detectors equipped with orthogonal anode/cathode collecting strips, drift strips and dedicated pulse processing allow a detection area of 6 x 20 mm(2) and excellent room temperature spectroscopic performance (0.82% FWHM at 661.7 keV). In this work, we investigated the potentialities of these detectors for prompt gamma-ray spectroscopy (PGS) in boron neutron capture therapy (BNCT). The detectors, exploiting the measurement of the 478 keV prompt gamma rays emitted by 94% Li-7 nuclides from the B-10(n, alpha)Li-7 reaction, are very appealing for the development of single-photon emission computed tomography (SPECT) systems and Compton cameras in BNCT. High-resolution gamma-ray spectra from B-10 samples under thermal neutrons were measured at the T.R.I.G.A. Mark II research nuclear reactor of the University of Pavia (Italy).
引用
收藏
页数:11
相关论文
共 41 条
[1]   Experimental results from Al/p-CdTe/Pt X-ray detectors [J].
Abbene, L. ;
Gerardi, G. ;
Turturici, A. A. ;
Del Sordo, S. ;
Principato, F. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 730 :135-140
[2]   Energy resolution and throughput of a new real time digital pulse processing system for x-ray and gamma ray semiconductor detectors [J].
Abbene, L. ;
Gerardi, G. ;
Raso, G. ;
Basile, S. ;
Brai, M. ;
Principato, F. .
JOURNAL OF INSTRUMENTATION, 2013, 8
[3]  
Abbene L., 2020, P 2020 IEEE NUCL SCI, DOI [10.1109/NSS/MIC42677.2020.9507987, DOI 10.1109/NSS/MIC42677.2020.9507987]
[4]   Recent advances in the development of high-resolution 3D cadmium-zinc-telluride drift strip detectors [J].
Abbene, Leonardo ;
Gerardi, Gaetano ;
Principato, Fabio ;
Buttacavoli, Antonino ;
Altieri, Saverio ;
Protti, Nicoletta ;
Tomarchio, Elio ;
Del Sordo, Stefano ;
Auricchio, Natalia ;
Bettelli, Manuele ;
Amade, Nicola Sarzi ;
Zanettini, Silvia ;
Zappettini, Andrea ;
Caroli, Ezio .
JOURNAL OF SYNCHROTRON RADIATION, 2020, 27 :1564-1576
[5]   Room-temperature X-ray response of cadmium-zinc-telluride pixel detectors grown by the vertical Bridgman technique [J].
Abbene, Leonardo ;
Principato, Fabio ;
Gerardi, Gaetano ;
Buttacavoli, Antonino ;
Cascio, Donato ;
Bettelli, Manuele ;
Amade, Nicola Sarzi ;
Seller, Paul ;
Veale, Matthew C. ;
Fox, Oliver ;
Sawhney, Kawal ;
Zanettini, Silvia ;
Tomarchio, Elio ;
Zappettini, Andrea .
JOURNAL OF SYNCHROTRON RADIATION, 2020, 27 :319-328
[6]   Digital fast pulse shape and height analysis on cadmium-zinc-telluride arrays for high-flux energy-resolved X-ray imaging [J].
Abbene, Leonardo ;
Principato, Fabio ;
Gerardi, Gaetano ;
Bettelli, Manuele ;
Seller, Paul ;
Veale, Matthew C. ;
Zambelli, Nicola ;
Benassi, Giacomo ;
Zappettini, Andrea .
JOURNAL OF SYNCHROTRON RADIATION, 2018, 25 :257-271
[7]   Development of new CdZnTe detectors for room-temperature high-flux radiation measurements [J].
Abbene, Leonardo ;
Gerardi, Gaetano ;
Raso, Giuseppe ;
Principato, Fabio ;
Zambelli, Nicola ;
Benassi, Giacomo ;
Bettelli, Manuele ;
Zappettini, Andrea .
JOURNAL OF SYNCHROTRON RADIATION, 2017, 24 :429-438
[8]   Strong mechanical adhesion of gold electroless contacts on CdZnTe deposited by alcoholic solutions [J].
Benassi, G. ;
Nasi, L. ;
Bettelli, M. ;
Zambelli, N. ;
Calestani, D. ;
Zappettini, A. .
JOURNAL OF INSTRUMENTATION, 2017, 12
[9]   CD1-XZNXTE4 GAMMA-RAY DETECTORS [J].
BUTLER, JF ;
LINGREN, CL ;
DOTY, FP .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (04) :605-609
[10]   Boron neutron capture therapy for glioblastoma multiforme:: clinical studies in Sweden [J].
Capala, J ;
Stenstam, BH ;
Sköld, KS ;
af Rosenschöld, PM ;
Giusti, V ;
Persson, C ;
Wallin, E ;
Brun, A ;
Franzen, L ;
Carlsson, JO ;
Salford, L ;
Ceberg, C ;
Persson, B ;
Pellettieri, L ;
Henriksson, R .
JOURNAL OF NEURO-ONCOLOGY, 2003, 62 (01) :135-144