The influence of femoral condylar lift-off on the wear of artificial knee joints

被引:56
作者
Jennings, L. M. [1 ]
Bell, C. J. [1 ]
Ingham, E. [1 ]
Komistek, R. D. [1 ]
Stone, M. H. [1 ]
Fisher, J. [1 ]
机构
[1] Univ Leeds, Sch Mech Engn, Inst Med & Biol Engn, Leeds LS2 9JT, W Yorkshire, England
关键词
total knee replacement; polyethylene wear; lift-off; knee simulator;
D O I
10.1243/09544119JEIM215
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In vivo fluoroscopic studies of patients with total knee replacements (TKRs) have shown lift-off of the femoral condyles from the tibial insert. This study investigated the influence of femoral condylar lift-off on the ultra-high molecular weight polyethylene (UHMWPE) wear of fixed bearing (FB) and rotating platform mobile bearing (RP MB) total knee replacements, using a physiological knee joint simulator. In the absence of lift-off, the RP MB knees exhibited a lower wear rate of 5.2 +/- 2.2 mm(3) per million cycles (mm(3)/MC) compared with 8.8 +/- 4.8 mm(3)/MC for the FB knees. The presence of femoral condylar lift-off was found to accelerate the wear of the FB and RP MB knees tested in this study to 16.4 +/- 2.9 and 16.9 +/- 2.9 mm(3)/MC respectively. For the RP MB knees the increase in wear rate was more marked, resulting in a similar wear rate for both designs of knee under lift-off conditions. In both cases the medial condyle displayed more wear damage. This study has shown that a small amount of abduction/adduction lift-off and medial-lateral shift increases wear and that the increase in wear is design dependent. In this simulator test, lift-off was simulated on every cycle, whereas the amount of wear and effect of lift-off clinically would depend on the frequency of occurrence of lift-off in vivo.
引用
收藏
页码:305 / 314
页数:10
相关论文
共 40 条
[11]   Wear of polyethylene in artificial knee joints [J].
Fisher, J ;
McEwen, HMJ ;
Barnett, PI ;
Bell, CJ ;
Stewart, TD ;
Stone, MH ;
Ingham, E .
CURRENT ORTHOPAEDICS, 2001, 15 (06) :399-405
[12]   Osteolysis associated with cemented total knee arthroplasty [J].
Griffin, FM ;
Scuderi, GR ;
Gillis, AM ;
Li, S ;
Jimenez, E ;
Smith, T .
JOURNAL OF ARTHROPLASTY, 1998, 13 (05) :592-598
[13]   Quantitative characterization of polyethylene debris isolated from periprosthetic tissue in early failure knee implants and early and late failure Charnley hip implants [J].
Howling, GI ;
Barnett, PI ;
Tipper, JL ;
Stone, MH ;
Fisher, J ;
Ingham, E .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2001, 58 (04) :415-420
[14]   The role of macrophages in osteolysis of total joint replacement [J].
Ingham, E ;
Fisher, J .
BIOMATERIALS, 2005, 26 (11) :1271-1286
[15]   Biological reactions to wear debris in total joint replacement [J].
Ingham, E ;
Fisher, J .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2000, 214 (H1) :21-37
[16]   Correlation between condylar lift-off and femoral component alignment [J].
Insall, JN ;
Scuderi, GR ;
Komistek, RD ;
Math, K ;
Dennis, DA ;
Anderson, DT .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (403) :143-152
[17]   Comparison of wear of mobile and fixed bearing knees tested in a knee simulator [J].
Johnson, TS ;
Laurent, MP ;
Yao, JQ ;
Blanchard, CR .
WEAR, 2003, 255 (7-12) :1107-1112
[18]   The effect of displacement control input parameters on tibiofemoral prosthetic knee wear [J].
Johnson, TS ;
Laurent, MP ;
Yao, JQ ;
Gilbertson, LN .
WEAR, 2001, 250 (PART 1) :222-226
[19]  
Kawanabe K, 2001, J BIOMED MATER RES, V54, P400, DOI 10.1002/1097-4636(20010305)54:3<400::AID-JBM130>3.0.CO
[20]  
2-Y