The influence of femoral condylar lift-off on the wear of artificial knee joints

被引:56
作者
Jennings, L. M. [1 ]
Bell, C. J. [1 ]
Ingham, E. [1 ]
Komistek, R. D. [1 ]
Stone, M. H. [1 ]
Fisher, J. [1 ]
机构
[1] Univ Leeds, Sch Mech Engn, Inst Med & Biol Engn, Leeds LS2 9JT, W Yorkshire, England
关键词
total knee replacement; polyethylene wear; lift-off; knee simulator;
D O I
10.1243/09544119JEIM215
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In vivo fluoroscopic studies of patients with total knee replacements (TKRs) have shown lift-off of the femoral condyles from the tibial insert. This study investigated the influence of femoral condylar lift-off on the ultra-high molecular weight polyethylene (UHMWPE) wear of fixed bearing (FB) and rotating platform mobile bearing (RP MB) total knee replacements, using a physiological knee joint simulator. In the absence of lift-off, the RP MB knees exhibited a lower wear rate of 5.2 +/- 2.2 mm(3) per million cycles (mm(3)/MC) compared with 8.8 +/- 4.8 mm(3)/MC for the FB knees. The presence of femoral condylar lift-off was found to accelerate the wear of the FB and RP MB knees tested in this study to 16.4 +/- 2.9 and 16.9 +/- 2.9 mm(3)/MC respectively. For the RP MB knees the increase in wear rate was more marked, resulting in a similar wear rate for both designs of knee under lift-off conditions. In both cases the medial condyle displayed more wear damage. This study has shown that a small amount of abduction/adduction lift-off and medial-lateral shift increases wear and that the increase in wear is design dependent. In this simulator test, lift-off was simulated on every cycle, whereas the amount of wear and effect of lift-off clinically would depend on the frequency of occurrence of lift-off in vivo.
引用
收藏
页码:305 / 314
页数:10
相关论文
共 40 条
[1]   Investigation of wear of knee prostheses in a new displacement/force-controlled simulator [J].
Barnett, PI ;
McEwen, HMJ ;
Auger, DD ;
Stone, MH ;
Ingham, E ;
Fisher, J .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2002, 216 (H1) :51-61
[2]   Comparison of wear in a total knee replacement under different kinematic conditions [J].
Barnett, PI ;
Fisher, J ;
Auger, DD ;
Stone, MH ;
Ingham, E .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2001, 12 (10-12) :1039-1042
[3]  
D'Lima DD, 2001, CLIN ORTHOP RELAT R, P124
[4]   In vivo three-dimensional determination of kinematics for subjects with a normal knee or a unicompartmental or total knee replacement [J].
Dennis, D ;
Komistek, R ;
Scuderi, G ;
Argenson, JN ;
Insall, J ;
Mahfouz, M ;
Aubaniac, JM ;
Haas, B .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A :104-115
[5]  
Dennis DA, 1998, CLIN ORTHOP RELAT R, P47
[6]   Femoral condylar lift-off in vivo in total knee arthroplasty [J].
Dennis, DA ;
Komistek, RD ;
Walker, SA ;
Cheal, EJ ;
Stiehl, JB .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (01) :33-39
[7]   In vivo fluoroscopic analysis of fixed-bearing total knee replacements [J].
Dennis, DA ;
Komistek, RD ;
Mahfouz, MR .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (410) :114-130
[8]   Fluoroscopic and gait analysis of the functional performance in stair ascent of two total knee replacement designs [J].
Fantozzi, S ;
Benedetti, MG ;
Leardini, A ;
Banks, SA ;
Cappello, A ;
Assirelli, D ;
Catani, F .
GAIT & POSTURE, 2003, 17 (03) :225-234
[9]   Posterior cruciate-retaining modular total knee arthroplasty - A 9- to 12-year follow-up investigation [J].
Fetzer, GB ;
Callaghan, JJ ;
Templeton, JE ;
Goetz, DD ;
Sullivan, PM ;
Kelley, SS .
JOURNAL OF ARTHROPLASTY, 2002, 17 (08) :961-966
[10]   Wear, debris, and biologic activity of cross-linked polyethylene in the knee - Benefits and potential concerns [J].
Fisher, J ;
McEwen, HMJ ;
Tipper, JL ;
Galvin, AL ;
Ingram, J ;
Kamali, A ;
Stone, MH ;
Ingham, E .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (428) :114-119