Breakdown Characteristics of a Long Air Gap Containing a Floating Conductor Under Positive Switching Impulse

被引:10
作者
Gao, Jiachen [1 ,2 ]
Wang, Linong [1 ]
Wu, Shaocheng [1 ]
Xie, Cheng [1 ]
Liu, Lei [3 ]
Li, Enwen [3 ]
Wang, Tingting [3 ]
Cavallini, Andrea [2 ]
机构
[1] Wuhan Univ, Sch Elect Engn & Automat, Wuhan 430072, Peoples R China
[2] Univ Bologna, Dept Elect Elect & Informat Engn Guglielmo Marcon, I-40136 Bologna, Italy
[3] China Southern Power Grid, Elect Power Res Inst, Guangzhou 510670, Peoples R China
关键词
Electrodes; Air gaps; Conductors; Discharges (electric); Switches; Power transmission lines; High-voltage techniques; discharges (electric); electric breakdown; power transmission lines; DISCHARGE VOLTAGE; MODEL;
D O I
10.1109/TDEI.2022.3201780
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Experiments on the breakdown characteristics of a long air gap containing a floating conductor under switching impulse are carried out to address issues in live-line work engineering. The effects of gap distance, floating conductor structure, wavefront time, and high altitude on breakdown voltage are investigated, respectively. The results show that a floating conductor with sharp protrusions reduces the breakdown voltage and produces the lowest breakdown voltage area (LBA). The maximum reduction rate of the breakdown voltage and the position of the LBA vary with the gap distance. The position of the LBA is also related to the floating conductor structure. The results indicate that different floating conductor structures with similar electric field distortions have a similar effect on the breakdown voltage. For the effect of wavefront time on breakdown characteristics, the results show that the breakdown voltage under switching impulse with a long wavefront time is higher than that under a standard switching impulse. For the effect of high altitude, the results show that the LBA at high altitude is different from that at low altitude, and the high-altitude breakdown voltage corrected using the International Electrotechnical Commission (IEC) altitude correction method is not exactly the same as the actual experimental results.
引用
收藏
页码:1913 / 1922
页数:10
相关论文
共 31 条
[1]  
[Anonymous], 2010, HIGH VOLTAGE TEST TE
[2]  
[Anonymous], 2018, IEC 60071-2
[3]   A consistent approach to estimate the breakdown voltage of high voltage electrodes under positive switching impulses [J].
Arevalo, L. ;
Wu, D. ;
Jacobson, B. .
JOURNAL OF APPLIED PHYSICS, 2013, 114 (08)
[4]  
Baldo G., 1989, PROC 6 INT S HIGH VO
[5]   SWITCHING SURGE STRENGTH OF LARGE AIR GAPS - PHYSICAL APPROACH [J].
CARRARA, G ;
THIONE, L .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1976, 95 (02) :512-524
[6]   Optical Emission Spectroscopy of Lightning Impulse Discharges in Long Air Gaps with and without Water Mist [J].
Chen, Bao-Hui ;
Deng, Jie ;
Pan, Bicheng ;
Liu, Yu ;
Zhou, Tiannian .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2021, 28 (04) :1110-1117
[7]   Experimental Study on Branch and Diffuse Type of Streamers in Leader Restrike of Long Air Gap Discharge [J].
Chen She ;
Zeng Rong ;
Zhuang Chijie ;
Zhou Xuan ;
Ding Yujian .
PLASMA SCIENCE & TECHNOLOGY, 2016, 18 (03) :305-310
[8]   Modelling for switching impulse breakdown of live working gaps between equipotential worker and transmission towers [J].
Fang, Yaqi ;
Wang, Linong ;
Li, Rui ;
Gao, Jiachen ;
Song, Bin ;
Liu, Kai .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2020, 14 (07) :1271-1278
[9]   A Modified Model for Discharge Voltage of AC Transmission Line-Tower Air Gaps [J].
Fang, Yaqi ;
Wang, Linong ;
Li, Rui ;
Zhang, Qiushi ;
Gao, Jiachen ;
Song, Bin .
IEEE ACCESS, 2019, 7 :71472-71480
[10]   Effect of a floating conductor on discharge characteristics of a long air gap under switching impulse [J].
Gao, Jiachen ;
Wang, Linong ;
Wu, Shaocheng ;
Xie, Cheng ;
Tan, Qipeng ;
Ma, Guoqiang ;
Tueraili, Hayinaer ;
Song, Bin .
JOURNAL OF ELECTROSTATICS, 2021, 114