The exact estimation of visual acuity by VEP technology: A report of 726 cases of eye injury

被引:3
作者
Rao, Guangxun [1 ]
Wu, Bingwei [1 ]
Zhang, Lingli [1 ]
机构
[1] Huazhong Univ Sci & Technol, Tongji Med Coll, Fac Forens Med, Wuhan 430030, Peoples R China
关键词
clinical forensic medicine; visual evoked potentials; visual acuity; least signal visual angle; amplitude and lateny of P(100); EVOKED-POTENTIALS;
D O I
10.1007/s11596-010-0125-1
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
This study explored the accuracy of using visual evoked potentials (VEP) technology for visual acuity estimation. The enrolled 726 patients with post-traumatic unilateral decrease in visual acuity included the injured eyes served as the experimental group, and the healthy eyes as the control group. The least signal visual angle (LSVA), and amplitude and latency of P(100) were chosen as test indexes. The results under different experimental conditions were recorded by PRVEP technology. All data collected were processed and analyzed by SPSS software. The results showed that the coincidence between subjective and VEP visual acuity was 96.7% in control group, but there was very significant difference in experimental group. It was concluded that with the regression formulation for the amplitude of P(100) and vision under LSVA, visual acuity can be estimated more accurately and impartially.
引用
收藏
页码:138 / 140
页数:3
相关论文
共 22 条
[1]   ACUITY ESTIMATED BY VISUALLY EVOKED-POTENTIALS IS AFFECTED BY SCALING [J].
CHAN, H ;
ODOM, JV ;
COLDREN, J ;
DOVE, C ;
CHAO, GM .
DOCUMENTA OPHTHALMOLOGICA, 1986, 62 (01) :107-117
[2]   RELATIONSHIP BETWEEN AMPLITUDE OF PATTERN DISPLACEMENT AND VISUAL EVOKED-POTENTIALS [J].
FENWICK, PBC ;
TURNER, C .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1977, 43 (01) :74-78
[3]   Pattern visual evoked potentials in the assessment of visual acuity in malingering [J].
Gundogan, Fatih C. ;
Sobaci, Gungor ;
Bayer, Atilla .
OPHTHALMOLOGY, 2007, 114 (12) :2332-2337
[4]  
Hashiba Ayae, 1997, Nippon Ganka Gakkai Zasshi, V101, P644
[5]  
HU J, 2008, INT J OPTHALMOL, V8, P2059
[6]   Test-retest reliability of swept visual evoked potential measurements of infant visual acuity and contrast sensitivity [J].
Lauritzen, L ;
Jorgensen, MH ;
Michaelsen, KF .
PEDIATRIC RESEARCH, 2004, 55 (04) :701-708
[7]   Molecular structure for NX(X = F, Cl, Br) and the contribution of polarization functions f orbitals [J].
Liu, YC ;
Jiang, G ;
Zhu, ZH .
ACTA PHYSICO-CHIMICA SINICA, 2002, 18 (02) :117-121
[8]  
PAN YF, 1999, CLIN EVOKED POTENTIA, P434
[9]  
SAKAUE H, 1990, INVEST OPHTH VIS SCI, V31, P506
[10]  
SOKAL S, 1978, VISION RES, V18, P33