Real-Time Ultrasound Detection of Breast Microcalcifications Using Multifocus Twinkling Artifact Imaging

被引:8
作者
Kang, Jinbum [1 ,2 ]
Han, Kanghee [1 ]
Song, Ilseob [1 ]
Kim, Kang-Sik [3 ]
Jang, Won Seuk [4 ]
Kim, Min Jung [5 ]
Yoo, Yangmo [1 ,6 ]
机构
[1] Sogang Univ, Dept Elect Engn, Seoul 04107, South Korea
[2] Univ Washington, Dept Bioengn, Seattle, WA 98105 USA
[3] Samsung Elect Co Ltd, Dept Hlth & Med Equipment, Suwon 16678, South Korea
[4] Yonsei Univ, Coll Med, Dept Med Engn, Seoul 03722, South Korea
[5] Yonsei Univ, Dept Radiol, Coll Med, Seoul 03722, South Korea
[6] Sogang Univ, Dept Biomed Engn, Seoul 04107, South Korea
基金
新加坡国家研究基金会;
关键词
Wires; Imaging; Acoustics; Surface roughness; Rough surfaces; Real-time systems; Doppler effect; Breast microcalcification; ultrasound; multifocus twinkling artifact imaging; biopsy guidance; RENAL-CALCULUS; GUIDED BIOPSY; CANCER; COLOR; MAMMOGRAPHY; DIAGNOSIS; SOCIETY; LESIONS; BENIGN;
D O I
10.1109/TMI.2021.3136901
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Detecting microcalcifications (MCs) in real time is important in the guidance of many breast biopsies. Due to its capability in visualizing biopsy needles without radiation hazards, ultrasound imaging is preferred over X-ray mammography, but it suffers from low sensitivity in detecting MCs. Here, we present a new nonionizing method based on real-time multifocus twinkling artifact (MF-TA) imaging for reliably detecting MCs. Our approach exploits time-varying TAs arising from acoustic random scattering on MCs with rough or irregular surfaces. To obtain the increased intensity of the TAs from MCs, in MF-TA, acoustic transmit parameters, such as the transmit frequency, the number of focuses and f-number, were optimized by investigating acoustical characteristics of MCs. A real-time MF-TA imaging sequence was developed and implemented on a programmable ultrasound research system, and it was controlled with a graphical user interface during real-time scanning. From an in-house 3D phantom and ex vivo breast specimen studies, the MF-TA method showed outstanding visibility and high-sensitivity detection for MCs regardless of their distribution or the background tissue. These results demonstrated that this nonionizing, noninvasive imaging technique has the potential to be one of effective image-guidance methods for breast biopsy procedures.
引用
收藏
页码:1300 / 1308
页数:9
相关论文
共 44 条
[1]  
Bae S, 2015, KOREAN J RADIOL, V16, P996
[2]   New relationships between breast microcalcifications and cancer [J].
Baker, R. ;
Rogers, K. D. ;
Shepherd, N. ;
Stone, N. .
BRITISH JOURNAL OF CANCER, 2010, 103 (07) :1034-1039
[3]   Combined screening with ultrasound and mammography vs mammography alone in women at elevated risk of breast cancer [J].
Berg, Wendie A. ;
Blume, Jeffrey D. ;
Cormack, Jean B. ;
Mendelson, Ellen B. ;
Lehrer, Daniel ;
Bohm-Velez, Marcela ;
Pisano, Etta D. ;
Jong, Roberta A. ;
Evans, W. Phil ;
Morton, Marilyn J. ;
Mahoney, Mary C. ;
Larsen, Linda Hovanessian ;
Barr, Richard G. ;
Farria, Dione M. ;
Marques, Helga S. ;
Boparai, Karan .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2008, 299 (18) :2151-2163
[4]  
Bitencourt Almir Galvão Vieira, 2018, Radiol Bras, V51, P106, DOI 10.1590/0100-3984.2017.0054
[5]   Screening Breast Ultrasound: Past, Present, and Future [J].
Brem, Rachel F. ;
Lenihan, Megan J. ;
Lieberman, Jennifer ;
Torrente, Jessica .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (02) :234-240
[6]   Microcalcifications in breast cancer: novel insights into the molecular mechanism and functional consequence of mammary mineralisation [J].
Cox, R. F. ;
Hernandez-Santana, A. ;
Ramdass, S. ;
McMahon, G. ;
Harmey, J. H. ;
Morgan, M. P. .
BRITISH JOURNAL OF CANCER, 2012, 106 (03) :525-537
[7]   Sonographic Twinkling Artifact for Renal Calculus Detection: Correlation with CT [J].
Dillman, Jonathan R. ;
Kappil, Mariam ;
Weadock, William J. ;
Rubin, Jonathan M. ;
Platt, Joel F. ;
DiPietro, Michael A. ;
Bude, Ronald O. .
RADIOLOGY, 2011, 259 (03) :911-916
[8]   The accuracy of ultrasound, stereotactic, and clinical core biopsies in the diagnosis of breast cancer, with an analysis of false-negative cases [J].
Dillon, MF ;
Hill, ADK ;
Quinn, CM ;
O'Doherty, A ;
McDermott, EW ;
O'Higgins, N .
ANNALS OF SURGERY, 2005, 242 (05) :701-707
[9]   Comparative study in patients with microcalcifications: full-field digital mammography vs screen-film mammography [J].
Fischer, U ;
Baum, F ;
Obenauer, S ;
Luftner-Nagel, S ;
von Heyden, D ;
Vosshenrich, R ;
Grabbe, E .
EUROPEAN RADIOLOGY, 2002, 12 (11) :2679-2683
[10]   STRUCTURE AND COMPOSITION OF MICROCALCIFICATIONS IN BENIGN AND MALIGNANT LESIONS OF THE BREAST - STUDY BY LIGHT-MICROSCOPY, TRANSMISSION AND SCANNING ELECTRON-MICROSCOPY, MICROPROBE ANALYSIS, AND X-RAY-DIFFRACTION [J].
FRAPPART, L ;
BOUDEULLE, M ;
BOUMENDIL, J ;
LIN, HC ;
MARTINON, I ;
PALAYER, C ;
MALLETGUY, Y ;
RAUDRANT, D ;
BREMOND, A ;
ROCHET, Y ;
FEROLDI, J .
HUMAN PATHOLOGY, 1984, 15 (09) :880-889