On initial ion velocities in MALDI: A novel FT-ICR MS approach

被引:10
|
作者
Tomalova, Iva [1 ,2 ]
Frankevich, Vladimir [1 ]
Zenobi, Renato [1 ]
机构
[1] ETH, Dept Chem & Appl Biosci, Zurich, Switzerland
[2] Masaryk Univ, Fac Sci, Dept Chem, CS-61137 Brno, Czech Republic
关键词
MALDI; Initial ion velocity; FT-ICR MS; ASSISTED LASER-DESORPTION; MATRIX; IONIZATION; TIME;
D O I
10.1016/j.ijms.2014.08.004
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Even after more than two decades of investigation, the question whether the initial velocity of ions generated by matrix-assisted laser desorption/ionization (MALDI) depends on their molecular weight or not remains unanswered. A novel method employing an internal MALDI source Fourier-transform ion cyclotron resonance mass spectrometry is used to measure the initial ion velocities of peptides with m/z values in the range of typical proteomic experiments. Simultaneous measurement of multiple matrix and analyte ions clearly shows initial ion velocities that depend on analyte or matrix molecular weight. The measured velocity values agree well with the published data. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:51 / 53
页数:3
相关论文
共 50 条
  • [41] Untargeted analysis of pure snail slime and snail slime-induced Au nanoparticles metabolome with MALDI FT-ICR MS
    Onzo, Alberto
    Pascale, Raffaella
    Acquavia, Maria Assunta
    Cosma, Pinalysa
    Gubitosa, Jennifer
    Gaeta, Carmine
    Iannece, Patrizia
    Tsybin, Yury
    Rizzi, Vito
    Guerrieri, Antonio
    Ciriello, Rosanna
    Bianco, Giuliana
    JOURNAL OF MASS SPECTROMETRY, 2021, 56 (05):
  • [42] Improved protein identification using automated high mass measurement accuracy MALDI FT-ICR MS peptide mass fingerprinting
    Horn, DM
    Peters, EC
    Klock, H
    Meyers, A
    Brock, A
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2004, 238 (02) : 189 - 196
  • [43] MALDI-FT-ICR-MS for archaeological lipid residue analysis
    2017, John Wiley and Sons Ltd, Southern Gate, Chichester, West Sussex, PO19 8SQ, United Kingdom (52):
  • [44] MALDI-FT-ICR-MS for archaeological lipid residue analysis
    Oras, Ester
    Vahur, Signe
    Isaksson, Sven
    Kaljurand, Ivari
    Leito, Ivo
    JOURNAL OF MASS SPECTROMETRY, 2017, 52 (10): : 689 - 700
  • [45] ACSAICHE 99009-Ionization reagents for enhanced speciation of petroleum compound classes by Electrospray Ionization FT-ICR Mass Spectrometry (ESI FT-ICR MS)
    Juyal, Priyanka
    Rodgers, Ryan P.
    Marshall, Alan G.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2008, 235
  • [46] Development of cooling system for cryogenic preamplifier in FT-ICR ion trap
    Choi, Y. S.
    Kim, D. L.
    Painter, T. A.
    Choi, M. C.
    Kim, H. S.
    Yoo, J. S.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 53A AND 53B, 2008, 985 : 375 - +
  • [47] Application of FT-ICR MS Equipped with Quadrupole Detection for Analysis of Crude Oil
    Cho, Eunji
    Witt, Matthias
    Hur, Manhoi
    Jung, Maeng-Joon
    Kim, Sunghwan
    ANALYTICAL CHEMISTRY, 2017, 89 (22) : 12101 - 12107
  • [48] Monitoring the liquid/liquid extraction of naphthenic acids in brazilian crude oil using electrospray ionization FT-ICR mass spectrometry (ESI FT-ICR MS)
    Colati, Keroly A. P.
    Dalmaschio, Guilherme P.
    de Castro, Eustaquio V. R.
    Gomes, Alexandre O.
    Vaz, Boniek G.
    Romao, Wanderson
    FUEL, 2013, 108 : 647 - 655
  • [49] Autophaser: An Algorithm for Automated Generation of Absorption Mode Spectra for FT-ICR MS
    Kilgour, David P. A.
    Wills, Rebecca
    Qi, Yulin
    O'Connor, Peter B.
    ANALYTICAL CHEMISTRY, 2013, 85 (08) : 3903 - 3911
  • [50] Determination of Unknown Compound in Aromatics by FT-ICR MS with Various Ionization Techniques
    ZHANG Yahe
    LU Hong
    REN Limin
    SHI Quan
    XU Chunming
    GUO Shaohui
    Acta Geologica Sinica(English Edition), 2015, (S1) : 439 - 439