Prestressed MF-FRP: Experimental Study of Rapid Retrofit Solution for Deteriorated Prestressed C-Channel Beams

被引:3
作者
McCoy, Brad C. [1 ]
Bourara, Zakariya [2 ]
Lucier, Gregory W. [2 ]
Seracino, Rudolf [2 ]
Liu, Min [2 ]
Lin, Sheng-Hsuan [2 ]
机构
[1] US Mil Acad, Dept Civil & Mech Engn, West Point, NY 10996 USA
[2] North Carolina State Univ, Dept Civil Construct & Environm Engn, Raleigh, NC 27695 USA
关键词
Strengthening and repair; Fiber-reinforced polymer (FRP); Mechanically fastened; Prestressed concrete; In-place concrete strength; FIBER-REINFORCED POLYMER; CONCRETE BEAMS; RC BEAMS; MEMBERS;
D O I
10.1061/(ASCE)CF.1943-5509.0001536
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents design and installation details and full-scale test results for a prestressed mechanically fastened fiber-reinforced polymer (MF-FRP) retrofit solution that restores the original operating and inventory rating of prestressed concrete C-channel bridge superstructures with prestress losses due to concrete deterioration and steel corrosion. A retrofit solution that can be installed rapidly and immediately restores prestress losses is desired to minimize impacts on commerce, public transportation, and emergency services. Six 9.41-m (30-ft) long C-channel beams were tested for three-point bending to failure. The results of the experimental study indicate that the MF-FRP retrofit is capable of immediately restoring deteriorated C-channel beams with a 36% reduction in capacity from the original operating and inventory ratings. In this study, the reduction in the capacity of the C-channel beams was induced in the lab by cutting the bottom strand of each stem of the C-channel beam to simulate total prestress losses at the point of maximum internal moment. Further, the results of the experimental study indicate that the examined MF-FRP retrofit solution can be installed in 4.1 labor hours per retrofitted C-channel beam. Therefore, a four-worker DOT maintenance crew can install the retrofit on up to seven beams in a single eight-hour workday. A layered sectional analysis can be used to predict the flexural capacity of retrofitted C-channel beams with very good accuracy.
引用
收藏
页数:17
相关论文
共 45 条
[1]  
AASHTO, 2017, LRFD BRIDG DES SPEC
[2]  
ACI (American Concrete Institute), 2010, 2144R ACI
[3]  
Ammons DavidN., 2001, MUNICIPAL BENCHMARKS
[4]  
[Anonymous], 2015, Steel Construction Manual, VFourteenth
[5]  
[Anonymous], 2018, The Manual for Bridge Evaluation, V3rd, P674
[6]  
ASTM, 2018, C42 ASTM
[7]   Analysis of RC beams strengthened with mechanically fastened FRP (MF-FRP) strips [J].
Bank, Lawrence C. ;
Arora, Dushyant .
COMPOSITE STRUCTURES, 2007, 79 (02) :180-191
[8]  
Borowicz D.T., 2002, THESIS U WISCONSIN M
[9]  
Cavalline T. L., 2015, Report No. FHWA/NC/2014-07
[10]  
Collins M.P., 1997, Prestressed Concrete Structures, P766