Comparison of dose calculation algorithms in slab phantoms with cortical bone equivalent heterogeneities

被引:46
作者
Carrasco, P.
Jornet, N.
Duch, M. A.
Panettieri, V.
Weber, L.
Eudaldo, T.
Ginjaume, M.
Ribas, M.
机构
[1] Hosp Santa Creu & Sant Pau, Barcelona 08025, Spain
[2] Univ Politecn Cataluna, Inst Tecn Energet, E-08028 Barcelona, Spain
[3] Univ Lund Hosp, Dept Radiat Phys, SE-22185 Lund, Sweden
关键词
heterogeneity correction; calculation algorithms; bone correction; treatment planning systems;
D O I
10.1118/1.2750972
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate the dose values predicted by several calculation algorithms in two treatment planning systems, Monte Carlo (MC) simulations and measurements by means of various detectors were performed in heterogeneous layer phantoms with water- and bone-equivalent materials. Percentage depth doses (PDDs) were measured with thermoluminescent dosimeters (TLDs), metal-oxide semiconductor field-effect transistors (MOSFETs), plane parallel and cylindrical ionization chambers, and beam profiles with films. The MC code used for the simulations was the PENELOPE code. Three different field sizes (10 X 10, 5 X 5, and 2 X 2 cm 2) were studied in two phantom configurations and a bone equivalent material. These two phantom configurations contained heterogeneities of 5 and 2 cm of bone, respectively. We analyzed the performance of four correction-based algorithms and one based on convolution superposition. The correction-based algorithms were the Batho, the Modified Batho, the Equivalent TAR implemented in the Cadplan (Varian) treatment planning system (TPS), and the Helax-TMS Pencil Beam from the Helax-TMS (Nucletron) TPS. The convolution-superposition algorithm was the Collapsed Cone implemented in the Helax-TMS. All the correction-based calculation algorithms underestimated the dose inside the bone-equivalent material for 18 MV compared to MC simulations. The maximum underestimation, in terms of root-mean-square (RMS), was about 15% for the Helax-TMS Pencil Beam (Helax-TMS PB) for a 2 X 2 cm2 field inside the bone-equivalent material. In contrast, the Collapsed Cone algorithm yielded values around 3%. A more complex behavior was found for 6 MV where the Collapsed Cone performed less well, overestimating the dose inside the heterogeneity in 3%-5%. The rebuildup in the interface bone-water and the penumbra shrinking in high-density media were not predicted by any of the calculation algorithms except the Collapsed Cone, and only the MC simulations matched the experimental values within the estimated uncertainties. The TLD and MOSFET detectors were suitable for dose measurement inside bone-equivalent materials, while parallel ionization chambers, applying the same calibration and correction factors as in water, systematically underestimated dose by 3%-5%. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:3323 / 3333
页数:11
相关论文
共 55 条
  • [1] COLLAPSED CONE CONVOLUTION OF RADIANT ENERGY FOR PHOTON DOSE CALCULATION IN HETEROGENEOUS MEDIA
    AHNESJO, A
    [J]. MEDICAL PHYSICS, 1989, 16 (04) : 577 - 592
  • [2] The impact of electron transport on the accuracy of computed dose
    Arnfield, MR
    Siantar, CH
    Siebers, J
    Garmon, P
    Cox, L
    Mohan, R
    [J]. MEDICAL PHYSICS, 2000, 27 (06) : 1266 - 1274
  • [3] ARNFIELD MR, 1998, INT J RADIAT ONCOL, V41, P707
  • [4] Experimental verification of convolution /superposition photon dose calculations for radiotherapy treatment planning
    Aspradakis, MM
    Morrison, RH
    Richmond, ND
    Steele, A
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (17) : 2873 - 2893
  • [5] BATHO HF, 1964, J CAN ASSOC RADIOL, V15, P39
  • [6] Comparison of dose calculation algorithms in phantoms with lung equivalent heterogeneities under conditions of lateral electronic disequilibrium
    Carrasco, P
    Jornet, N
    Duch, MA
    Weber, L
    Ginjaume, M
    Eudaldo, T
    Jurado, D
    Ruiz, A
    Ribas, M
    [J]. MEDICAL PHYSICS, 2004, 31 (10) : 2899 - 2911
  • [7] Photon beam relative dose validation of the DPM Monte Carlo code in lung-equivalent media
    Chetty, IJ
    Charland, PM
    Tyagi, N
    McShan, DL
    Fraass, BA
    Bielajew, AF
    [J]. MEDICAL PHYSICS, 2003, 30 (04) : 563 - 573
  • [8] Comparison of dose calculation algorithms with Monte Carlo methods for photon arcs
    Chow, JCL
    Wong, E
    Chen, JZ
    Van Dyk, J
    [J]. MEDICAL PHYSICS, 2003, 30 (10) : 2686 - 2694
  • [9] BACKSCATTER DOSE PERTURBATION AT HIGH ATOMIC-NUMBER INTERFACES IN MEGAVOLTAGE PHOTON BEAMS
    DAS, IJ
    KAHN, FM
    [J]. MEDICAL PHYSICS, 1989, 16 (03) : 367 - 375
  • [10] Measurement of absorbed dose with a bone-equivalent extrapolation chamber
    DeBlois, F
    Abdel-Rahman, W
    Seuntjens, JP
    Podgorsak, EB
    [J]. MEDICAL PHYSICS, 2002, 29 (03) : 433 - 440