On-line ion-exchange pretoncentration and determination of traces of platinum by electrothermal atomic absorption spectrometry

被引:22
|
作者
García, MMG [1 ]
Rojas, FS [1 ]
Ojeda, CB [1 ]
de Torres, AG [1 ]
Pavón, JMC [1 ]
机构
[1] Univ Malaga, Fac Sci, Dept Analyt Chem, Malaga 29071, Spain
关键词
platinum; electrothermal atomic absorption spectrometry; preconcentration; microcolumn; flow injection; vegetation; soil; waters; and catalyst samples;
D O I
10.1007/s00216-002-1679-y
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method to determine trace amounts of platinum in different samples based on electrothermal atomic absorption spectrometry is described. The preconcentration step is performed on a chelating resin microcolumn [1,5-bis(2-pyridyl)-3-sulfophenyl methylene thiocarbonohydrazide (PSTH) immobilized on an anion-exchange resin (Dowex 1x8-200)] placed in the autosampler arm. The combination of a peristaltic pump for sample loading and the atomic absorption spectrometer pumps for elution through a selection valve simplifies the hardware. The peristaltic pump and the selection valve are easily controlled electronically with two switches placed in the autosampler, which are activated when the autosampler arm is down. Thus, the process is fully automated without any modification of the software of the atomic absorption spectrometer. Under the optimum conditions with a 60-s preconcentration time, a sample flow rate of 2.4 mL min(-1), and an injection volume of eluent of 40 muL, a linear calibration graph was obtained in the range 0-100ngmL(-1). The enrichment factor was 14. The detection limit under these conditions is 1 ng mL(-1), and the relative standard deviation (RSD) is 1.6% for 10 ng mL(-1) of Pt. The method has been applied to the determination of platinum in catalyst, vegetation, soil, and natural water samples. The results showed good agreement with the certified value and the recoveries of Pt added to samples were 98-105%.
引用
收藏
页码:1229 / 1233
页数:5
相关论文
共 50 条
  • [1] On-line ion-exchange preconcentration and determination of traces of platinum by electrothermal atomic absorption spectrometry
    M. M. González García
    F. Sánchez Rojas
    C. Bosch Ojeda
    A. García de Torres
    J. M. Cano Pavón
    Analytical and Bioanalytical Chemistry, 2003, 375 : 1229 - 1233
  • [2] Ion-exchange preconcentration and determination of vanadium in milk samples by electrothermal atomic absorption spectrometry
    Lopez-Garcia, Ignacio
    Vinas, Pilar
    Romero-Romero, Rafael
    Hernandez-Cordoba, Manuel
    TALANTA, 2009, 78 (4-5) : 1458 - 1463
  • [3] Separation of Silver by Ion-Exchange Resin and Its Determination by Electrothermal Atomic Absorption Spectrometry
    Chamsaz, M.
    Riazi, M. M.
    ASIAN JOURNAL OF CHEMISTRY, 2012, 24 (03) : 957 - 960
  • [4] Automated on-line separation-preconcentration system for platinum determination by electrothermal atomic absorption spectrometry
    Ojeda, CB
    Rojas, FS
    Pavón, JMC
    de Torres, AG
    ANALYTICA CHIMICA ACTA, 2003, 494 (1-2) : 97 - 103
  • [5] Determination of traces of metals in steel by ion-exchange separation and atomic spectrometry
    Oguma, K
    Kato, K
    Kurashima, Y
    Seki, T
    Ono, A
    Ishibashi, Y
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1999, 85 (02): : 119 - 123
  • [6] Flow injection on-line electrothermal atomic absorption spectrometry
    Alonso, EV
    de Torres, AG
    Pavón, JMC
    TALANTA, 2001, 55 (02) : 219 - 232
  • [7] Application of flow injection on-line electrothermal atomic absorption spectrometry to the determination of rhodium
    Rojas, FS
    Ojeda, CB
    Pavón, JMC
    ANNALI DI CHIMICA, 2005, 95 (06) : 437 - 445
  • [8] An ion-exchange method for speciation of antimony by flow injection electrothermal atomic absorption spectrometry
    Rojas, F. Sanchez
    Ojeda, C. Bosch
    Pavon, J. M. Cano
    TALANTA, 2007, 71 (02) : 918 - 922
  • [9] PRECONCENTRATION AND DETERMINATION OF TRACES OF STRONTIUM IN NATURAL-WATERS BY ION-EXCHANGE AND FLAME ATOMIC-ABSORPTION SPECTROMETRY
    YEBRABIURRUN, MC
    BERMEJOBARRERA, A
    BERMEJOBARRERA, P
    BULLETIN DES SOCIETES CHIMIQUES BELGES, 1992, 101 (06): : 473 - 478
  • [10] Flow injection on-line pre-concentration of platinum coupled with electrothermal atomic absorption spectrometry
    Limbeck, Andreas
    Rudolph, Elisabeth
    Hann, Stephan
    Koellensperger, Gunda
    Stingeder, Gerhard
    Rendl, Josef
    1600, Royal Society of Chemistry (19):