Effect of metal opaquer on the final color of 3 ceramic crown types on 3 abutment configurations

被引:10
作者
Arif, Rabia [1 ]
Yilmaz, Burak [2 ]
Mortazavi, Aras [3 ]
Ozcelik, Tuncer B. [4 ]
Johnston, William M. [1 ]
机构
[1] Ohio State Univ, Coll Dent, Dept Gen Practice & Mat Sci, 305 W 12th Ave,3005S Postle Hall, Columbus, OH 43210 USA
[2] Ohio State Univ, Coll Dent, Dept Restorat Sci & Prosthodont, Columbus, OH 43210 USA
[3] Ohio State Univ, Coll Dent, Columbus, OH 43210 USA
[4] Baskent Univ, Dept Prosthodont, Ankara, Turkey
关键词
ZIRCONIA IMPLANT ABUTMENTS; FRACTURE STRENGTH; BENDING MOMENTS; CEMENT COLOR; IN-VITRO; TITANIUM; THICKNESS; SHADE; RESTORATIONS; MULTICENTER;
D O I
10.1016/j.prosdent.2017.11.030
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The effect of a recently introduced metal opaquer when used to mask the color of a titanium abutment under ceramic crown systems is unknown. Purpose. The purpose of this study was to compare the color coordinates of 3 ceramic crown types-characterized monolithic lithium disilicate (LDC) (IPS e.max; Ivoclar Vivadent AG), layered lithium disilicate (LDL) (IPS e.max; Ivoclar Vivadent AG), and layered zirconia (ZL) (H.C. Starck)-on 3 abutment configurations, nonopaqued titanium (Ti), resin opaqued titanium (Op), and zirconia (Zir). In addition, the color differences (CIEDE2000) were evaluated among the 3 crown types on 3 different abutment substrates. Material and methods. Ten Ti disks (10x1 mm) were fabricated with computer-aided design and computer-aided manufacturing (CAD-CAM) to represent the Ti abutments. Five Ti specimens were opaqued (Op) (whiteMetal Opaquer wMO; Blue Sky Bio), and 5 were not opaqued (Ti). Ten zirconia disks were fabricated with CAD-CAM and sintered (10x1.2 mm). Five disks were used as backings to represent Zir abutments, and 5 disks were layered with 1 mm of porcelain (131, IPS e.Max Ceram; Ivoclar Vivadent AG) to represent layered zirconia crowns (ZL). Ten lithium disilicate plates (14x14x1.2 mm) were sectioned from CAD blocks (B1 IPS e.Max CAD; Ivoclar Vivadent AG). Five plates were layered with the same porcelain (B1, 1 mm), and 5 plates were surface characterized and glazed. An LDL crown on a Zir abutment configuration was used as the control. The 3 simulated crown types (n=5) were optically connected to each of the 3 abutment types, and the color of the 9 groups was measured using a spectroradiometer. Measured data were reported in CIELab coordinates. CIELab data were used to calculate color differences between the control and the 8 experimental groups. Color data were summarized for each group, and analyzed by repeated-measures ANOVA. For pairwise comparisons, a Bonferroni correction of t tests was used, and for interpretive analysis of resulting color difference data, a 1-way ANOVA and subsequent Tukey testing for pairwise comparisons were used. Results. The statistical significance of the analysis of color coordinates was found to be P <=.002. Although 3-way interaction was not found to be significant (P=.335), all three 2-way interactions of the main effects were found to be significant (P <=.002). All crown types on the Zir abutment revealed color differences from the control group. The color differences of the crown types on the Op and Zir abutment configurations compared with the control (LDL/Zir) were not (P>.05) statistically different. Conclusions. Colors of tested crown systems on Ti backing were each unacceptably different from the control group. Colors of these systems on zirconia backing were not perceivably different. Use of opaquer on titanium backing resulted in a small color difference from the control group (P>.05) for each crown system, demonstrating that it may be used to prevent the unfavorable metal show-through that can influence the final color of all ceramic crown systems tested.
引用
收藏
页码:375 / 381
页数:7
相关论文
共 28 条
[1]   POSTFATIGUE FRACTURE RESISTANCE OF MODIFIED PREFABRICATED ZIRCONIA IMPLANT ABUTMENTS [J].
Alqahtani, Fawaz ;
Flinton, Robert .
JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (02) :299-305
[2]   Properties of sufficiency and statistical tests [J].
Bartlett, MS .
PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1937, 160 (A901) :0268-0282
[3]   Clinical Outcomes of Implant Abutments in the Anterior Region: A Systematic Review [J].
Bidra, Avinash S. ;
Rungruanganunt, Patchanee .
JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2013, 25 (03) :159-176
[4]   Influence of abutment material on the gingival color of implant-supported all-ceramic restorations: a prospective multicenter study [J].
Bressan, Eriberto ;
Paniz, Gianluca ;
Lops, Diego ;
Corazza, Boris ;
Romeo, Eugenio ;
Favero, Gianantonio .
CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (06) :631-637
[5]   EFFECT OF ABUTMENT TOOTH COLOR, CEMENT COLOR, AND CERAMIC THICKNESS ON THE RESULTING OPTICAL COLOR OF A CAD/CAM GLASS-CERAMIC LITHIUM DISILICATE-REINFORCED CROWN [J].
Chaiyabutr, Yada ;
Kois, John C. ;
LeBeau, Dene ;
Nunokawa, Gary .
JOURNAL OF PROSTHETIC DENTISTRY, 2011, 105 (02) :83-90
[6]   Fracture Strength Study of Internally Connected Zirconia Abutments Reinforced with Titanium Inserts [J].
Chun, Hyo-Jung ;
Yeo, In-Sung ;
Lee, Joo-Hee ;
Kim, Seong-Kyun ;
Heo, Seong-Joo ;
Koak, Jai-Young ;
Han, Jung-Suk ;
Lee, Shin-Jae .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2015, 30 (02) :346-350
[7]  
(CIE) CIdIE, 2004, AUSTR CIE PUBL
[8]   Effect of brand and shade of resin cements on the final color of lithium disilicate ceramic [J].
Dede, Dogu Omur ;
Ceylan, Gozlem ;
Yilmaz, Burak .
JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (04) :539-544
[9]   Influence of implant abutment material on the color of different ceramic crown systems [J].
Dede, Dogu Omur ;
Armaganci, Arzu ;
Ceylan, Gozlem ;
Celik, Ersan ;
Cankaya, Soner ;
Yilmaz, Burak .
JOURNAL OF PROSTHETIC DENTISTRY, 2016, 116 (05) :764-769
[10]   The influence of porcelain layer thickness on the final shade of ceramic restorations [J].
Dozic, A ;
Kleverlaan, CJ ;
Meegdes, M ;
van der Zel, J ;
Feilzer, AJ .
JOURNAL OF PROSTHETIC DENTISTRY, 2003, 90 (06) :563-570