Determination of cationic polyelectrolytes using a photometric titration with crystal violet as a color indicator

被引:19
作者
Masadome, T [1 ]
机构
[1] Ariake Natl Coll Technol, Dept Sci & Chem Engn, Fukuoka 8368585, Japan
关键词
photometric titration; cationic polyelectrolytes; colloidal titration; crystal violet; glycol chitosan; methylglycol chitosan; poly (diallyidimethylammonium chloride);
D O I
10.1016/S0039-9140(02)00581-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The reaction of the cationic dye, crystal violet (CV) with the anionic polyelectrolytes such as potassium poly (vinyl sulfate) (PVSK) results in a decrease of the absorbance of CV at the maximum absorption wavelength (590 nm). This change of the absorption spectra of the CV has been already applied to the determination of anionic polyelectrolytes using flow injection analysis method. In this paper, CV was applied to the indicator for the determination of cationic polyelectrolytes such as poly (diallyldimethylammonium chloride) (Cat-floc) by photometric titration, using a PVSK solution as a titrant. The end-point of the titration is detected as the break point of the titration curve. A linear relationship between the concentration of cationic polyelectrolyte and the end-point volume of the titrant exists in the concentration range from 0 to 5 x 10(-5) eq. mol dm(-3) for Cat-floc, glycol chitosan and methylglycol chitosan. The effects of the concentration of CV and coexisting electrolytes in the sample solution and the effect of pH of the sample solution on the degree of the change of absorbance at the end-point were also examined. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:659 / 666
页数:8
相关论文
共 26 条
[1]   TOLUIDINE BLUE SELECTIVE PLASTICIZED POLY(VINYL CHLORIDE) MEMBRANE-ELECTRODE FOR COLLOIDAL TITRATION [J].
HATTORI, T ;
KAWANISHI, T ;
KATO, M .
BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1994, 67 (02) :405-409
[2]   Colloidal titration of chitosan and critical unit of chitosan to the potentiometric colloidal titration with poly(vinyl sulfate) using toluidine blue as indicator [J].
Hattori, T ;
Katai, K ;
Kato, M ;
Izume, M ;
Mizuta, Y .
BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1999, 72 (01) :37-41
[3]  
HORN D, 1978, PROGR COLLOID POLYM, V65, P251
[4]   NEW DETECTION METHOD OF END-POINT IN COLLOID TITRATION USING AN IODIDE ION-SELECTIVE ELECTRODE [J].
ISHIBASHI, N ;
KINA, K ;
TAMURA, K .
ANALYTICAL LETTERS, 1975, 8 (12) :867-872
[5]  
JAQUES LB, 1980, PHARMACOL REV, V31, P99
[6]   COLLOID TITRATION OF HEPARIN USING CAT-FLOC (POLYDIALLYLDIMETHYL AMMONIUM-CHLORIDE) AS STANDARD POLYCATION [J].
KATAYAMA, T ;
TAKAI, KI ;
KARIYAMA, R ;
KANEMASA, Y .
ANALYTICAL BIOCHEMISTRY, 1978, 88 (02) :382-387
[7]  
KINA K, 1974, JPN ANALYST, V23, P1082
[8]  
KINA K, 1976, BUNSEKI KIKI, V14, P551
[9]  
LINDHARDT RJ, 1991, CHEM IND, V2, P45
[10]   EFFECT OF HYDROPHOBICITY OF MARKER ANIONS ON THE SENSITIVITY OF END-POINT DETECTION FOR POTENTIOMETRIC TITRATIONS OF ANIONIC POLYELECTROLYTES [J].
MASADOME, T ;
IMATO, T .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 352 (06) :596-597