Cuspal deflection and microleakage in premolar teeth restored with resin-based composites with and without an intermediary flowable layer

被引:63
作者
Cara, R. R.
Fleming, G. J. P. [1 ]
Palin, W. M.
Walmsley, A. D.
Burke, F. J. T.
机构
[1] Univ Med & Pharm, Dept Dent Mat, Cluj Napoca, Romania
[2] Dublin Dent Sch & Hosp, Trinity Coll, Div Oral Biosci, Mat Sci Unit, Dublin, Ireland
[3] Univ Birmingham, Sch Dent, Birmingham B4 6NN, W Midlands, England
关键词
cuspal deflection; cervical microleakage; resin-based composite; flowable RBC; POLYMERIZATION SHRINKAGE; IN-VITRO; HYGROSCOPIC EXPANSION; CONTRACTION STRESS; DENTAL COMPOSITES; FILLED ADHESIVES; INTERNAL VOIDS; RESTORATIONS; MOVEMENT; DEFORMATION;
D O I
10.1016/j.jdent.2007.01.005
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To assess cuspal deflection and cervical enamel microleakage with and without an intermediary flowable RBC layer for the incremental restoration of mesio-occluso-distal (MOD) cavities with two resin-based composites (RBCs). Methods: Forty sound upper premolar teeth had standardised MOD cavities prepared. Restoration of the teeth involved the placement of the RBCs (Filtek (TM) P60 or Filtek (TM) Supreme) in eight increments with the appropriate bonding system with and without an intermediary flowable RBC layer (Filtek (TM) Flow). Buccal and palatal cusp deflections were recorded post-irradiation using a twin channel deflection measuring gauge. Following restoration, the teeth were thermocycled, immersed in a 0.2% basic fuchsin dye for 24 h, sagittally sectioned and examined for cervical enamel microleakage. Results: A significant reduction in cuspal deflection was evident when both RBC materials were used to restore the cavity by employing an intermediary flowable (P < 0.001) compared with when no intermediary flowable was utilised. No statistically significant differences were identified in microleakage between the teeth restored with Filtek (TM) P60 or Filtek (TM) Supreme when an intermediary flowable (Filtek (TM) Flow) was employed. Conclusions: The results of the current study suggest that there was a benefit to the operator in terms of a reduction in cuspal deflection but not from the maintenance of the synergism of the adhesive bond, namely microleakage at the cervical enamel cavosurface margin, when an intermediate layer of a flowable RBC was used under higher elastic modulus RBCs. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:482 / 489
页数:8
相关论文
共 52 条
[1]   Cuspal movement and microleakage in premolar teeth restored with a packable composite cured in bulk or in increments [J].
Abbas, G ;
Fleming, GJP ;
Harrington, E ;
Shortall, ACC ;
Burke, FJT .
JOURNAL OF DENTISTRY, 2003, 31 (06) :437-444
[2]  
Alomari QD, 2001, OPER DENT, V26, P406
[3]  
Attar Nuray, 2003, J Can Dent Assoc, V69, P516
[4]   A characterization of first-generation flowable composites [J].
Bayne, SC ;
Thompson, JY ;
Swift, EJ ;
Stamatiades, P ;
Wilkerson, M .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1998, 129 (05) :567-577
[5]  
Belli S, 2001, OPER DENT, V26, P70
[6]  
Beznos C, 2001, OPER DENT, V26, P60
[7]   Contraction stress of flowable composite materials and their efficacy as stress-relieving layers [J].
Braga, RR ;
Hilton, TJ ;
Ferracane, JL .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2003, 134 (06) :721-728
[9]   THE DEFORMATION OF CUSPS BY BONDED POSTERIOR COMPOSITE RESTORATIONS - AN INVITRO STUDY [J].
CAUSTON, BE ;
MILLER, B ;
SEFTON, J .
BRITISH DENTAL JOURNAL, 1985, 159 (12) :397-400
[10]  
Cerutti A, 2004, AM J DENT, V17, P295