Relationship between Prosthesis-Patient Mismatch and Pro-Brain Natriuretic Peptides after Aortic Valve Replacement

被引:0
作者
Melina, Giovanni [1 ]
Angeloni, Emiliano [1 ]
Benedetto, Umberto [1 ]
Refice, Simone [1 ]
Miele, Antonio [1 ]
Miele, Cristina [2 ]
Ciavarella, Giuseppino M. [2 ]
Sinatra, Riccardo [1 ]
机构
[1] Univ Roma La Sapienza, Policlin S Andrea, Dept Cardiac Surg, I-00189 Rome, Italy
[2] Univ Roma La Sapienza, Policlin S Andrea, Dept Cardiol, I-00189 Rome, Italy
关键词
EFFECTIVE ORIFICE AREA; LONG-TERM SURVIVAL; STENOSIS; IMPACT; SIZE; MORTALITY; DISEASE; ASSOCIATION; AGE;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aim of the study: It has been shown previously that elevated plasma levels of B-type natriuretic peptide (BNP) and its N-terminal fragment (NT-pro-BNP) are related to the degree and progression of native aortic valve disease. In addition, NT-pro-BNP levels have been shown to decrease after successful aortic valve replacement (AVR). The presence of a valve prosthesis-patient mismatch (PPM) may affect the beneficial effects of AVR, however. The study aim was to investigate the relationship between PPM and NT-pro-BNP plasma levels late after AVR. Methods: A series of consecutive patients (42 males, 31 females; mean age 66 13 years) who had undergone isolated AVR between May 2004 and July 2007 was enrolled into the study. Patients with preoperative moderate to severe mitral regurgitation, coronary artery disease, left ventricular (LV) dysfunction (ejection fraction <45%) and serum creatinine >150 mmol/l were excluded. PPM was defined severe as an indexed effective orifice area (EOAi) <= 0.65cm(2)/m(2), or moderate when the EOAi was 0.66-0.85 cm(2)/m(2). Plasma NT-pro-BNP levels and echocardiographic assessments were performed in all patients during routine follow up after surgery. Results: The patients received either a biological (n = 42) or mechanical (n = 31) prosthesis. Among the patients, 21 had no PPM, 27 moderate PPM, and 25 severe PPM. At a median follow up of 18 months, the mean NT-pro-BNP plasma level was 532 pg/ml (95% CI: 393.1-671.6), and the mean LV mass index (LVMI) 120 +/- 4 g/m(2), the LVEF 60 +/- 1%, the peak aortic prosthesis gradient 28 +/- 2 mmHg, and the EOAi 0.74 +/- 0.02 cm(2)/m(2). Multivariate statistical analysis showed that NT-pro-BNP level correlated with age (beta = 0.57, p <0.0001), LVMI (beta = 0.32, p = 0.02), NYHA class (beta = 0.50, p = 0.003) and EOAi (beta = -0.38, p = 0.02). Conclusion: The study results showed that NT-pro-BNP levels were independently related to PPM late after isolated AVR in patients with preserved LV function. However, further investigations are required to confirm these findings and to identify their clinical implications.
引用
收藏
页码:171 / 176
页数:6
相关论文
共 50 条
  • [41] Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement in Asian Patients
    Chen, Ying-Hwa
    Chang, Hsiao-Huang
    Kuo, Chia-Cheng
    Leu, Hsin-Bang
    Lin, Su-Man
    ANNALS OF THORACIC SURGERY, 2022, 114 (05) : 1612 - 1619
  • [42] Impact of Suture Techniques for Aortic Valve Replacement on Prosthesis-Patient Mismatch
    Kim, Hyo-Hyun
    Lee, Sak
    Joo, Hyun-Chel
    Kim, Jung-Hwan
    Youn, Young-Nam
    Yoo, Kyung-Jong
    Lee, Seung-Hyun
    ANNALS OF THORACIC SURGERY, 2020, 109 (03) : 661 - 667
  • [43] Factors Affecting Survival After Mitral Valve Replacement in Patients With Prosthesis-Patient Mismatch
    Aziz, Abdulhameed
    Lawton, Jennifer S.
    Maniar, Hersh S.
    Pasque, Michael K.
    Damiano, Ralph J., Jr.
    Moon, Marc R.
    ANNALS OF THORACIC SURGERY, 2010, 90 (04) : 1202 - 1210
  • [44] Prosthesis-patient mismatch after transcatheter aortic valve implantation
    Miyasaka, Masaki
    CARDIOVASCULAR INTERVENTION AND THERAPEUTICS, 2022, 37 (04) : 615 - 625
  • [45] Prosthesis-Patient Mismatch Causes a Significantly Increased Risk of Operative Mortality in Aortic Valve Replacement
    Shahzeb, Khan Muhammad
    Imran, Bawany Faizan
    Asadullah, Khan
    Mehwish, Hussain
    HEART SURGERY FORUM, 2014, 17 (03) : E127 - E131
  • [46] Hemodynamic and Clinical Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Implantation
    Ewe, See Hooi
    Muratori, Manuela
    Delgado, Victoria
    Pepi, Mauro
    Tamborini, Gloria
    Fusini, Laura
    Klautz, Robert J. M.
    Gripari, Paola
    Bax, Jeroen J.
    Fusari, Melissa
    Schalij, Martin J.
    Marsan, Nina Ajmone
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (18) : 1910 - 1918
  • [47] Impact of Prosthesis-Patient Mismatch on Left Ventricular Myocardial Mechanics After Transcatheter Aortic Valve Replacement
    Poulin, Frederic
    Yingchoncharoen, Teerapat
    Wilson, William M.
    Horlick, Eric M.
    Genereux, Philippe
    Tuzcu, E. Murat
    Stewart, William
    Osten, Mark D.
    Woo, Anna
    Thavendiranathan, Paaladinesh
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2016, 5 (02):
  • [48] Discongruence Index - Simple Indicator to Predict Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement -
    Alberto de Agustin, Jose
    Islas, Fabian
    Jimenez-Quevedo, Pilar
    Nombela-Franco, Luis
    Rueda Linares, Andrea
    Mahia, Patricia
    Marcos-Alberca, Pedro
    Pozo, Eduardo
    Gomez de Diego, Jose Juan
    Luaces, Maria
    Nunez-Gil, Ivan-Javier
    Angel Garcia-Fernandez, Miguel
    Fernandez-Ortiz, Antonio
    Macaya, Carlos
    Perez de Isla, Leopoldo
    CIRCULATION JOURNAL, 2018, 82 (11) : 2880 - 2886
  • [49] Impact of Prosthesis Size and Prosthesis-Patient Mismatch on Outcomes in Younger Female Patients Undergoing Aortic Valve Replacement
    Kolkailah, Ahmed A.
    Hirji, Sameer A.
    Ejiofor, Julius I.
    Del Val, Fernando Ramirez
    Chowdhury, Ritam
    McGurk, Siobhan
    Lee, Jiyae
    Kaneko, Tsuyoshi
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2020, 32 (02) : 219 - 228
  • [50] Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement
    Blais, C
    Dumesnil, JG
    Baillot, R
    Simard, S
    Doyle, D
    Pibarot, P
    CIRCULATION, 2003, 108 (08) : 983 - 988