Liquid-xenon detector under the intensive pulse irradiation conditions

被引:4
|
作者
Kirsanov, M. A. [1 ]
机构
[1] Natl Res Nucl Univ, MEPhI Moscow Engn Phys Inst, Kashirskoe Highway 31, Moscow 115409, Russia
关键词
IONIZATION-CHAMBER;
D O I
10.1088/1742-6596/675/4/042014
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
The effect of intense pulsed irradiation on the operation of the liquid xenon spectrometer was studied. The ionization chamber filled with liquid xenon was irradiated by bremsstrahlung pulses of the microtron. The pulse repetition rate was 400 Hz. The absorbed dose ranged from 10(-7) to 0.1 Gy per pulse. Stable operation of the liquid xenon spectrometer in the intervals between the pulses of the accelerator was shown for a long time.
引用
收藏
页数:4
相关论文
共 50 条
  • [11] Ion processes in a liquid-xenon ionization chamber under high-intensity pulsed irradiation
    M. A. Kirsanov
    I. M. Obodovskiy
    Instruments and Experimental Techniques, 2010, 53 : 185 - 193
  • [12] On a discriminating liquid-xenon detector for SUSY dark-matter observation
    Cline, DB
    NUCLEAR PHYSICS B, 1996, : 304 - 313
  • [13] Ion processes in a liquid-xenon ionization chamber under high-intensity pulsed irradiation
    Kirsanov, M. A.
    Obodovskiy, I. M.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2010, 53 (02) : 185 - 193
  • [14] LIQUID-XENON PROPORTIONAL COUNTER
    LUBKIN, GB
    PHYSICS TODAY, 1972, 25 (05) : 19 - &
  • [15] POSITION-SENSITIVE LIQUID-XENON DETECTOR FOR GAMMA-RAYS
    GUSHCHIN, EM
    KRUGLOV, AA
    OBODOVSKII, IM
    POKACHALOV, SG
    SHILOV, VA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1982, 25 (03) : 561 - 564
  • [16] Liquid-xenon γ-camera with ionisation readout
    Solovov, V
    Chepel, V
    Lopes, MI
    Neves, F
    Marques, RF
    Policarpo, AJPL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 478 (1-2): : 435 - 439
  • [17] MPGDs in Compton imaging with liquid-xenon
    Duval, S.
    Breskin, A.
    Carduner, H.
    Cussonneau, J. -P.
    Lamblin, J.
    Le Ray, P.
    Morteau, E.
    Oger, T.
    Stutzmann, J. -S.
    Thers, D.
    JOURNAL OF INSTRUMENTATION, 2009, 4
  • [18] LIQUID-XENON SCINTILLATION GAMMA SPECTROMETER
    BARABANOV, IR
    GAVRIN, VN
    PSHUKOV, AM
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1985, 28 (05) : 1034 - 1036
  • [19] Thermal stabilization system for the RED-100 liquid-xenon emission detector
    V. V. Ananiev
    A. I. Bolozdynya
    K. F. Vlasik
    V. V. Dmitrenko
    Yu. V. Efremenko
    Z. M. Uteshev
    V. V. Sosnovtsev
    I. A. Tolstukhin
    A. V. Shakirov
    R. R. Shafigullin
    A. V. Khromov
    Instruments and Experimental Techniques, 2015, 58 : 581 - 586
  • [20] Status and Design of Two-Phase Liquid-Xenon Compton-Imaging Detector
    Wahl, Christopher G.
    Bernard, Ethan P.
    Kachulis, Christopher
    Edwards, Blair
    Larsen, Nicole A.
    Tennyson, Brian
    Cahn, Sidney B.
    McKinsey, Daniel N.
    Destefano, Nicholas E.
    Gai, Moshe
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 1541 - 1546