Performance of an artefact reduction algorithm in the diagnosis of invitro vertical root fracture in four different root filling conditions on CBCT images

被引:41
作者
de Rezende Barbosa, G. L. [1 ]
Melo, S. L. Sousa [2 ]
Alencar, P. N. B. [1 ]
Nascimento, M. C. C. [1 ]
Almeida, S. M. [1 ]
机构
[1] Univ Estadual Campinas, Dept Oral Diag, Piracicaba Dent Sch, Div Radiol, Sao Paulo, Brazil
[2] Univ Iowa, Coll Dent, Dept Oral Pathol Radiol & Med, Iowa City, IA 52242 USA
关键词
algorithms; cone-beam CT; diagnostic tests; root canal filling materials; root fracture; BEAM COMPUTED-TOMOGRAPHY; PERIAPICAL RADIOGRAPHY; INTRAORAL RADIOGRAPHY; CT; TEETH; ABSENCE;
D O I
10.1111/iej.12477
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
AimTo evaluate the influence of an artefact reduction algorithm (ARA) and several root filling materials on the detection of root fractures on cone-beam computed tomography (CBCT) images. MethodologyForty-four teeth were divided into control and fractured groups and scanned on a Picasso Trio CBCT device under four conditions: unrestored, filled with gutta-percha cones, cast-gold or fibreglass posts; either with or without applying the ARA. Three calibrated examiners assessed the images. ROC analysis, anova and pairwise Tukey LSD test were performed. ResultsNo significant difference between the groups with and without the ARA was observed. There was no significant interaction between the algorithm and root condition. On the other hand, there was a significant difference in the mean values of sensitivity (Sn) and accuracy (Ac) amongst the different root filling groups (P0.001). ConclusionsThe application of the ARA did not influence the diagnosis of root fractures, and its effects did not depend on root conditions. In relation to the filling materials, gold posts reduced the overall CBCT diagnostic ability, regardless of the use of the ARA.
引用
收藏
页码:500 / 508
页数:9
相关论文
共 36 条
[1]   Comparison of intraoral radiography and cone-beam computed tomography for the detection of horizontal root fractures: an in vitro study [J].
Avsever, Hakan ;
Gunduz, Kaan ;
Orhan, Kaan ;
Uzun, Ismail ;
Ozmen, Bilal ;
Egrioglu, Erol ;
Midilli, Muhammed .
CLINICAL ORAL INVESTIGATIONS, 2014, 18 (01) :285-292
[2]   Artifacts in CT: Recognition and avoidance [J].
Barrett, JF ;
Keat, N .
RADIOGRAPHICS, 2004, 24 (06) :1679-1691
[3]   Cone beam CT scans with and without artefact reduction in root fracture detection of endodontically treated teeth [J].
Bechara, B. ;
McMahan, C. Alex ;
Moore, W. S. ;
Noujeim, M. ;
Teixeira, F. B. ;
Geha, H. .
DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (05)
[4]   Evaluation of a cone beam CT artefact reduction algorithm [J].
Bechara, B. ;
McMahan, C. A. ;
Geha, H. ;
Noujeim, M. .
DENTOMAXILLOFACIAL RADIOLOGY, 2012, 41 (05) :422-428
[5]   Metal artefact reduction with cone beam CT: an in vitro study [J].
Bechara, B. B. ;
Moore, W. S. ;
McMahan, C. A. ;
Noujeim, M. .
DENTOMAXILLOFACIAL RADIOLOGY, 2012, 41 (03) :248-253
[6]   Use of cone-beam volumetric tomography in the diagnosis of root fractures [J].
Bernardes, Ricardo Affonso ;
de Moraes, Ivaldo Gomes ;
Hungaro Duarte, Marco Antonio ;
Azevedo, Bruno C. ;
de Azevedo, Jose Ribamar ;
Bramante, Clovis Monteiro .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 108 (02) :270-277
[7]   Evaluation of Two Iterative Techniques for Reducing Metal Artifacts in Computed Tomography [J].
Boas, F. Edward ;
Fleischmann, Dominik .
RADIOLOGY, 2011, 259 (03) :894-902
[8]   Comparison of intraoral radiography and limited cone beam computed tomography for the assessment of root-fractured permanent teeth [J].
Bornstein, Michael M. ;
Woelner-Hanssen, Andrea B. ;
Sendi, Pedram ;
von Arx, Thomas .
DENTAL TRAUMATOLOGY, 2009, 25 (06) :571-577
[9]   A comparison of cone beam computed tomography and periapical radiography for the detection of vertical root fractures in nonendodontically treated teeth [J].
Brady, E. ;
Mannocci, F. ;
Brown, J. ;
Wilson, R. ;
Patel, S. .
INTERNATIONAL ENDODONTIC JOURNAL, 2014, 47 (08) :735-746
[10]   Ex vivo evaluation of artifacts mimicking fracture lines on cone-beam computed tomography produced by different root canal sealers [J].
Brito-Junior, M. ;
Santos, L. A. N. ;
Faria-e-Silva, A. L. ;
Pereira, R. D. ;
Sousa-Neto, M. D. .
INTERNATIONAL ENDODONTIC JOURNAL, 2014, 47 (01) :26-31