Birmingham mid-head resection periprosthetic fractures: Case report

被引:1
作者
Fraile Gamarra, Ines [1 ]
Viseu Pinheiro, Juan Fernando Jimenez [1 ]
Cano Gala, Carlos [1 ]
Blanco Blanco, Juan Francisco [1 ]
机构
[1] Complejo Asistencial Univ Salamanca, Paseo San Vicente 58-182, Salamanca 37001, Spain
来源
INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS | 2019年 / 64卷
关键词
Case report; Birmingham; Periprosthetic fracture; Subtrochanteric; Mid-Head resection; Total hip arthroplasty; PROXIMAL FEMORAL FRACTURE; NECK FRACTURES; HIP; ARTHROPLASTY;
D O I
10.1016/j.ijscr.2019.10.012
中图分类号
R61 [外科手术学];
学科分类号
摘要
INTRODUCTION: Total hip arthroplasty in young patients can cause problems when it comes to choosing a suitable implant. The Birmingham Mid-Head Resection prosthesis (BMHR) offers the option of preserving bone stock despite its poor quality in the femoral neck. Femoral neck fractures are a known complication of hip resurfacing prostheses and the main reason for revision surgery. Retaining the femoral implant may cause difficulties in osteosynthesis carried out with implants habitually used for intertrochanteric or femoral neck fractures (e.g., a screw-plate device or a cephalomedullary nail) [2]. PRESENTATION OF CASE: We present the case of an 81-year-old patient who underwent surgery for right hip osteoarthritis and received a Birmingham Mid-Head Resection prosthesis. She had no history of previous fractures due to frailty. While on holiday, she sustained a periprosthetic fracture as a result of a fall. While the most common fracture in resurfacing prosthesis is produced in the femoral neck, in this case the patient sustained a subtrochanteric fracture. This fracture was surgically treated by means of open reduction and internal fixation with trochanteric plate and three cerclages. DISCUSSION: Olsen et al. [8] described two fracture patterns: transcervical vertical shear type and subcapital type. In our patient's case, the fracture pattern was different to those described, as the fracture started in the cervical area and reached the subtrochanteric area. This change in the standard periprosthetic fracture pattern leads to a change in the therapeutic attitude that must be adopted. CONCLUSION: BMHR prostheses are metal-on-metal implants that resulted from the development of the standard resurfacing prostheses used to treat hip osteoarthritis in young patients with the goal of preserving as much bone stock as possible. In this paper we will describe a rare complication in this type of prosthesis and how it was surgically treated after reviewing the available literature.(C) 2019 Published by Elsevier Ltd on behalf of IJS Publishing Group Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页码:174 / 176
页数:3
相关论文
共 14 条
[1]   The SCARE 2018 statement: Updating consensus Surgical CAse REport (SCARE) guidelines [J].
Agha, Riaz A. ;
Borrelli, Mimi R. ;
Farwana, Reem ;
Koshy, Kiron ;
Fowler, Alexander J. ;
Orgill, Dennis P. ;
Zhu, Hongyi ;
Alsawadi, Abdulrahman ;
Noureldin, Ashraf ;
Rao, Ashwini ;
Enam, Ather ;
Thoma, Achilleas ;
Bashashati, Mohammad ;
Vasudevan, Baskaran ;
Beamish, Andrew ;
Challacombe, Ben ;
De Wilde, Rudy Leon ;
Machado-Aranda, David ;
Laskin, Daniel ;
Muzumdar, Dattatraya ;
D'cruz, Anil ;
Manning, Todd ;
Healy, Donagh ;
Pagano, Duilio ;
Goel, Prabudh ;
Ranganathan, Priya ;
Pai, Prathamesh S. ;
Raja, Shahzad ;
Athe, M. Hammad ;
Kadioazlu, Huseyin ;
Nixon, Iain ;
Mukherjee, Indraneil ;
Gomez Riva, Juan ;
Raveendran, Kandiah ;
Derbyshire, Laura ;
Valmasoni, Michele ;
Chalkoo, Mushtaq ;
Raison, Nicholas ;
Muensterer, Oliver ;
Bradley, Patrick ;
Roberto, Coppola ;
Afifi, Raafat ;
Rosin, David ;
Klappenbach, Roberto ;
Wynn, Rolf ;
Giordano, Salvatore ;
Basu, Somprakas ;
Surani, Salim ;
Suman, Paritosh ;
Thorat, Mangesh .
INTERNATIONAL JOURNAL OF SURGERY, 2018, 60 :132-136
[2]   Fixation of a complex comminuted proximal femoral fracture in the presence of a Birmingham hip resurfacing prosthesis [J].
Aning, J ;
Aung, H ;
Mackinnon, J .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2005, 36 (09) :1127-1129
[3]   Periprosthetic fractures in the resurfaced hip-A case report and review of the literature [J].
Brennan, Stephen A. ;
Devitt, Brian M. ;
O'Neill, Cathleen J. ;
Nicholson, Paul .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2013, 44 (02) :263-265
[4]  
Daniel J, 2008, ORTHOPEDICS S2, V31
[5]   Femoral neck fracture following hip resurfacing THE EFFECT OF ALIGNMENT OF THE FEMORAL COMPONENT [J].
Davis, E. T. ;
Olsen, M. ;
Zdero, R. ;
Waddell, J. P. ;
Schemitsch, E. H. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (11) :1522-1527
[6]  
Inc SaN, 2009, AD BON REM BIRM HIP
[7]   Femoral neck fractures after metal-on-metal total hip resurfacing [J].
Marker, David R. ;
Seyler, Thorsten M. ;
Jinnah, Riyaz H. ;
Delanois, Ronald E. ;
Ulrich, Slif D. ;
Mont, Michael A. .
JOURNAL OF ARTHROPLASTY, 2007, 22 (07) :66-71
[8]   Hip Resurfacing versus Total Hip Arthroplasty: A Systematic Review Comparing Standardized Outcomes [J].
Marshall, Deborah A. ;
Pykerman, Karen ;
Werle, Jason ;
Lorenzetti, Diane ;
Wasylak, Tracy ;
Noseworthy, Tom ;
Dick, Donald A. ;
O'Connor, Greg ;
Sundaram, Aish ;
Heintzbergen, Sanne ;
Frank, Cy .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (07) :2217-2230
[9]   A Biomechanical Comparison of Epiphyseal Versus Metaphyseal Fixed Bone-Conserving Hip Arthroplasty [J].
Olsen, Michael ;
Sellan, Michael ;
Zdero, Rad ;
Waddell, James P. ;
Schemitsch, Emil H. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A :122-127
[10]   A Biomechanical Investigation of Implant Alignment and Femoral Neck Notching With the Birmingham Mid-Head Resection [J].
Olsen, Michael ;
Lewis, Peter M. ;
Waddell, James P. ;
Schemitsch, Emil H. .
JOURNAL OF ARTHROPLASTY, 2010, 25 (06) :112-117