Modelling of solid state nuclear track detector devices for radon measurements

被引:13
|
作者
Andriamanatena, R
Bacmeister, GU
Freyer, K
Ghose, R
Jonsson, G
Kleis, T
Treutler, HC
Enge, W
机构
[1] Univ Kiel, Inst Reine & Angew Kernphys, D-24118 Kiel, Germany
[2] Univ Autonoma Barcelona, Dept Fis, Bellaterra 089193, Spain
[3] UFZ Helmholtz Ctr Environm Res, Sekt Analyt, D-04318 Leipzig, Germany
[4] Lund Inst Technol, S-22100 Lund, Sweden
关键词
LR-115; track etching rate; bulk etching rate; radon measurements; EU-project;
D O I
10.1016/S1350-4487(97)00159-5
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Theoretical analytical calculations of the radon registration have been performed for the solid state nuclear track detectors (SSNTD) LR-115 Type II (peliculable) produced by Kodak-Pathe (France). Known and measured properties of LR-115 together with the well established etching theory using "Huygens' principle" were used to carry out these detailed calculations for different types of exposure devices for indoor room and outdoor soil measurements. The results of these modeling calculations are compared with experimental calibration measurements and show good agreement.
引用
收藏
页码:657 / 662
页数:6
相关论文
共 8 条
  • [1] The calibration of the solid state nuclear track detector LR 115 for radon measurements
    Gericke, C
    Ghose, R
    Jönsson, G
    Freyer, K
    Treutler, HC
    Enge, W
    RADIATION MEASUREMENTS, 1999, 31 (1-6) : 363 - 366
  • [2] SURFACE CHEMICAL ETCHING BEHAVIOR OF LR-115 TYPE II SOLID STATE NUCLEAR TRACK DETECTOR
    Mehta, Vimal
    Singh, S. P.
    Chauhan, R. P.
    Mudahar, G. S.
    ROMANIAN REPORTS IN PHYSICS, 2015, 67 (03) : 865 - 871
  • [3] FEATURES OF A NEW RUSSIAN TRACK DETECTOR FOR RADON MEASUREMENT
    CHAMBAUDET, A
    PAUTOV, V
    KLEIN, D
    BARENBOIM, G
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1993, 22 (1-4): : 289 - 290
  • [4] A parameterization of nuclear track profiles in CR-39 detector
    Azooz, A. A.
    Al-Nia'emi, S. H.
    Al-Jubbori, M. A.
    COMPUTER PHYSICS COMMUNICATIONS, 2012, 183 (11) : 2470 - 2479
  • [5] Direct determination of bulk etching rate for LR-115-II solid state nuclear track detectors
    T A Salama
    U Seddik
    T M Hegazy
    A Ahmed Morsy
    Pramana, 2006, 67 : 529 - 534
  • [6] Direct determination of bulk etching rate for LR-115-II solid state nuclear track detectors
    Salama, T. A.
    Seddik, U.
    Hegazy, T. M.
    Morsy, A. Ahmed
    PRAMANA-JOURNAL OF PHYSICS, 2006, 67 (03): : 529 - 534
  • [7] USE OF RADIOMETER WITH CELLULOSE NITRATE DETECTOR (CND) IN INDOOR RADON MEASUREMENTS IN OMSK, 1993
    UVAROV, VV
    KULAKOV, VM
    RADIATION MEASUREMENTS, 1995, 25 (1-4) : 587 - 590
  • [8] DETECTOR OF IONIZATION CHAMBER-TYPE IN PULSE MODE FOR MEASUREMENTS OF RADON CONCENTRATION IN AIR
    Calin, Marian Romeo g
    Calin, Mihaela Antonina
    Radulescu, Ileana
    ROMANIAN JOURNAL OF PHYSICS, 2016, 61 (9-10): : 1591 - 1603