Depth of cure of 10 resin-based composites light-activated using a laser diode, multi-peak, and single-peak light-emitting diode curing lights

被引:19
作者
Rocha, Mateus Garcia [1 ]
Maucoski, Cristiane [2 ,3 ]
Roulet, Jean-Francois [1 ]
Price, Richard Bengt [2 ]
机构
[1] Univ Florida, Coll Dent, Ctr Dent Biomat, Dept Restorat Dent Sci, Gainesville, FL USA
[2] Dalhousie Univ, Fac Dent, Dept Dent Clin Sci, 5981 Univ Ave, Halifax, NS B3H 4R2, Canada
[3] Univ Estadual Ponta Grossa, Dept Restorat Dent, Ponta Grossa, Parana, Brazil
关键词
Resin-based composites; Polymerization; Light curing units; ISO; 4049; Radiant exposure; Beam profile; Exposure reciprocity; EXPOSURE RECIPROCITY LAW; PATIENT SIMULATOR; EMISSION-SPECTRUM; HIGH IRRADIANCE; BOND STRENGTH; POLYMERIZATION; RESTORATIONS; TRANSMISSION; ATTENUATION; OUTPUT;
D O I
10.1016/j.jdent.2022.104141
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To evaluate the depth of cure (DOC) of ten contemporary resin-based composites (RBCs), light-cured using different LCUs and exposure times. Methods: The power, radiant emittance, irradiance, radiant exposure (RE), and beam profiles from a laser (M, Monet), a multi-peak (V, Valo Grand), and single-peak (S, SmartLite Pro) LCU were measured. The DOC was measured using a 6-mm diameter metal mold and a solvent dissolution method to remove the uncured RBC. The length of the remaining RBC was divided by 2. The exposure times were: 1 s and 3 s for M, 10 s and 20 s for V, and 10 s and 20 s for S. Data were analyzed using: Bland-Altman distribution, Pearson's Correlation, and an artificial neural network (ANN) to establish the relative importance of the factors on the DOC (alpha=0.05; beta=0.2). Results: Significant differences were found in the DOC achieved by the different LCUs and composites. The laser LCU emitted the highest power, radiant emittance is used above and in the tables and delivered the highest irradiance. However, this LCU used for 1 s delivered the lowest RE and produced the shortest DOC in all ten RBCs. The ANN demonstrated that the RE is the most critical factor for the DOC. Bland-Altman comparisons showed that the DOCs achieved with the laser LCU used for 1 s were between 17 and 34% shorter than the other conditions. Conclusions: Although the laser LCU cured all 10 RBCs when used for 1 s, it produced the shallowest DOC, and some RBCs did not achieve their minimum DOC threshold. The RE and not the irradiance was the most important factor in determining the DOC of these 10 RBCs. Clinical significance: Despite delivering high power and irradiance, the laser used for l s delivered a lower radiant exposure than the conventional LCUs used for 10 s. This resulted in a shorter DOC.
引用
收藏
页数:10
相关论文
共 71 条
[1]   Effect of the amount of light energy transmitted through CAD/CAM resin block on bonding performance of four types of resin cement adhesive systems [J].
Abe, Kaho ;
Asano, Takashi ;
Aida, Masahiro ;
Nishiyama, Norihiro ;
Komiyama, Osamu .
DENTAL MATERIALS JOURNAL, 2020, 39 (05) :792-802
[2]   Influence of different curing modes on flexural properties, fracture toughness, and wear behavior of dual-cure provisional resin-based composites [J].
Akiba, Shunsuke ;
Takamizawa, Toshiki ;
Tsujimoto, Akimasa ;
Moritake, Nobuyuki ;
Ishii, Ryo ;
Barkmeier, Wayne W. ;
Latta, Mark A. ;
Miyazaki, Masashi .
DENTAL MATERIALS JOURNAL, 2019, 38 (05) :728-737
[3]   Effect of Mold Type and Diameter on the Depth of Cure of Three Resin-Based Composites [J].
AlShaafi, M. M. ;
AlQussier, A. ;
AlQahtani, M. Q. ;
Price, R. B. .
OPERATIVE DENTISTRY, 2018, 43 (05) :520-529
[4]  
[Anonymous], 2021, MONET LASER CURING L
[5]  
[Anonymous], 2009, Dentistry - Polymer-based restorative materials, V4th
[6]  
[Anonymous], 2014, ANSI Z136 1 STANDARD
[7]  
[Anonymous], 2018, ISO 10650
[8]   Use of Artificial Neural Network in Determination of Shade, Light Curing Unit, and Composite Parameters' Effect on Bottom/Top Vickers Hardness Ratio of Composites [J].
Arjsu, Hacer Deniz ;
Dalkilic, Evrim Eliguzeloglu ;
Alkan, Fehime ;
Erol, Sebnem ;
Uctasli, Mine Betul ;
Cebi, Alican .
BIOMED RESEARCH INTERNATIONAL, 2018, 2018
[9]   Effect of light irradiation condition on gap formation under polymeric dental restoration; OCT study [J].
Bakhsh, Turki A. ;
Tagami, Jyunji ;
Sadr, Alireza ;
Luong, Minh N. ;
Turkistani, Alaa ;
Almhimeed, Yasser ;
Alshouibi, Ehab .
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2020, 30 (03) :194-200
[10]   Hands-on training based on quantifying radiant exposure improves how dental students cure composites: Skill retention at 2-year follow-up [J].
Balhaddad, Abdulrahman A. ;
Marghalani, Abdullah A. ;
Raderman, Michael A. ;
Miginsky, Elaine ;
Massey, Ward ;
Strassler, Howard ;
Anne Melo, Mary .
EUROPEAN JOURNAL OF DENTAL EDUCATION, 2021, 25 (03) :582-591