Flow injection chemiluminescence method for determination of ribavirin based on enhancement of luminol-persulfate reaction

被引:8
|
作者
Lu, Y [1 ]
Zhang, ZJ [1 ]
He, DY [1 ]
Hu, YF [1 ]
机构
[1] SW Normal Univ, Dept Chem, Inst Analyt Sci, Chongqing, Peoples R China
关键词
chemiluminescence; flow injection analysis; luminol; sodium persulfate ribavirin;
D O I
10.1081/AL-120021545
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel flow injection chemiluminescence (FI-CL) method for the determination of ribavirin is developed based on the enhancing effect of the analyte on CL emission of luminol oxidized by sodium persulfate in alkaline solution. The CL emission is correlated with the ribavirin concentration in the range from 0.01 to 1.0mugmL(-1), and the detection limit (3sigma) is 0.004mugmL(-1). The relative standard deviation is 2.8% (n = 11, 0.1 mugmL(-1) ribavirin). The method was successfully applied to the determination of ribavirin in pharmaceutical preparations.
引用
收藏
页码:1587 / 1595
页数:9
相关论文
共 50 条
  • [1] Flow injection chemiluminescence method for determination of nifedipine based on persulfate-luminol reaction
    He, SH
    Lü, Y
    He, DY
    Hu, YF
    Zhang, ZJ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (04) : 474 - 476
  • [2] Sensitive determination of captopril by flow injection analysis with chemiluminescence detection based on the enhancement of the luminol reaction
    Economou, A
    Themelis, DG
    Theodoridis, G
    Tzanavaras, PD
    ANALYTICA CHIMICA ACTA, 2002, 463 (02) : 249 - 255
  • [3] Sensitive flow-injection chemiluminescence determination of terbutaline sulfate based on enhancement of the luminol–permanganate reaction
    Zhouping Wang
    Zhujun Zhang
    Zhifeng Fu
    Xiao Zhang
    Analytical and Bioanalytical Chemistry, 2004, 378 : 834 - 840
  • [4] Sensitive flow-injection chemiluminescence determination of terbutaline sulfate based on enhancement of the luminol-permanganate reaction
    Wang, ZP
    Zhang, ZJ
    Fu, ZF
    Zhang, X
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (03) : 834 - 840
  • [5] Determination of ribavirin by flow injection chemiluminescence
    Juqing Jin1
    2School of Medicine
    3Pharmacy Faculty of Fujian Medical University
    JournalofNanjingMedicalUniversity, 2006, (05) : 266 - 270
  • [6] Determination of ampicillin and amoxycillin by flow injection chemiluminescence method based on their enhancing effects on the luminol-periodate reaction
    Li, YH
    Tang, YH
    Yao, H
    Fu, JM
    LUMINESCENCE, 2003, 18 (06) : 313 - 317
  • [7] Flow-injection inhibition chemiluminescence determination of indapamide based on luminol-ferricyanide reaction
    Wang, ZP
    Zhang, ZJ
    Zhang, XO
    Fu, ZF
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 35 (01) : 1 - 7
  • [8] Flow-injection determination of ornidazole by chemiluminescence detection based on a luminol-ferricyanide reaction
    Lv, Y
    Zhang, ZJ
    He, DY
    Hu, YF
    ANALYTICAL SCIENCES, 2003, 19 (04) : 625 - 627
  • [9] Chemiluminescence flow injection analysis of reducing agents based on the luminol reaction
    Kubo, H
    Toriba, A
    ANALYTICA CHIMICA ACTA, 1997, 353 (2-3) : 345 - 349
  • [10] Development of a luminol-based chemiluminescence flow-injection method for the determination of dichlorvos pesticide
    Wang, JN
    Zhang, C
    Wang, HX
    Yang, FZ
    Zhang, XR
    TALANTA, 2001, 54 (06) : 1185 - 1193