Augmentation on Heat Transfer and Friction Factor in Three Sides Solar Air Heaters Having an Arrangement of Multi-V and Transverse Wire Roughness on the Absorber Plate

被引:3
作者
Kumar, Dhananjay [1 ]
Prasad, Laljee [1 ]
机构
[1] Natl Inst Technol, Mech Engn Dept, Jamshedpur 831014, Jharkhand, India
关键词
Artificial roughness; airflow; heat transmission; pressure drop; solar energy; solar air heaters; RIB ROUGHNESS; THERMOHYDRAULIC PERFORMANCE; THERMAL PERFORMANCE; DISCRETE RIBS; DUCT; OPTIMIZATION; CHANNELS;
D O I
10.5541/ijot.796532
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper present the experimental inquiry on heat transfer and friction features enrichment adopting new-fangled of three side's synthetically rugged rectangular duct solar air heaters (SAHs). The roughened rectangular SAH ducts has been an arrangement of multi-v and transverse wire (top wall multi-v and two side walls transverse) covered with glass on three sides. It has various appliances such as crop drying, seasoning of timber, space heating, industrial purpose, etc. The rectangular duct used has a width to height ratio, W/H, equal to 8, relative raggedness pitch, P/e, wide-ranging from 10 - 25, relative raggedness height, e/D, varied from 0.018 - 0.042 and flow Reynolds number, Re, occupied from 3500 - 12,000 for fixed values of relative raggedness width, W/w, of 6 and an angle of attack, alpha, equal to 60 degrees. The heat transmission and friction features of this roughened duct is compared with plane ones under identical working conditions. The maximum augmentation in heat transmission and friction feature is identified to be 6.42 and 6.44 times over the smooth duct respectively. The enhancement in air temperature streaming under three side's synthetically rugged SAH duct is found to be 54.47% more than that of the smooth one. Three side's artificially rugged rectangular duct SAHs are preferable over plane ones collectively and tentatively
引用
收藏
页码:109 / 117
页数:9
相关论文
共 33 条
[21]   Nusselt number and friction factor correlations for solar air heater duct having protrusions as roughness elements on absorber plate [J].
Yadav, Sanjay ;
Kaushal, Maneesh ;
Varun ;
Siddhartha .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2013, 44 :34-41
[22]   NUMERICAL OPTIMIZATION OF THE THERMAL PERFORMANCE OF A SOLAR AIR CHANNEL HAVING DISCRETE MULTI V-RIB ROUGHNESS ON THE ABSORBER PLATE [J].
Kumar, Anil ;
Saini, R. P. ;
Saini, J. S. .
HEAT TRANSFER RESEARCH, 2016, 47 (05) :449-469
[23]   Heat transfer and friction factor characteristic investigation of roughened solar air heater using arc-shaped wire rib roughness [J].
Ghritlahre, Harish Kumar .
INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2021, :5085-5099
[24]   Effect of roughness elements on thermal and thermohydraulic performance of double pass solar air heater duct having discrete multi V-shaped and staggered rib roughness on both sides of the absorber plate [J].
Ravi, Ravi Kant ;
Saini, R. P. .
EXPERIMENTAL HEAT TRANSFER, 2018, 31 (01) :47-67
[25]   Experimental Investigation of Heat Transfer and Friction Characteristics of Arc-Shaped Roughness Elements Having Central Gaps on the Absorber Plate of Solar Air Heater [J].
Pandey, Navneet Kumar ;
Bajpai, Vijay Kumar .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2016, 138 (04)
[26]   Experimental investigation on heat transfer augmentation of solar air heater using shot blasted V-corrugated absorber plate [J].
Poongavanam, Ganesh Kumar ;
Panchabikesan, Karthik ;
Leo, Anto Joseph Deeyoko ;
Ramalingam, Velraj .
RENEWABLE ENERGY, 2018, 127 :213-229
[27]   Heat transfer and friction characteristics of solar air heater ducts having integral inclined discrete ribs on absorber plate [J].
Aharwal, K. R. ;
Gandhi, Bhupendra K. ;
Saini, J. S. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2009, 52 (25-26) :5970-5977
[28]   Analysis on Optimal Thermohydraulic Performance of Solar Air Heater Having Multiple V-shaped Wire Rib Roughness on Absorber Plate [J].
Kumar, Dhananjay ;
Prasad, Laljee .
INTERNATIONAL ENERGY JOURNAL, 2018, 18 (02) :153-170
[29]   Heat transfer and friction factor of solar air heater having duct roughened artificially with discrete multiple v-ribs [J].
Kumar, Anil ;
Saini, R. P. ;
Saini, J. S. .
JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2012, 4 (03)
[30]   Heat Transfer Augmentation of a Solar Air Heater Using a Twisted V-Shaped Staggered Rib Over the Absorber Plate [J].
Kumar, Dheeraj ;
Layek, Apurba .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2023, 145 (02)