Investigation of preferred viscosity of irreversible hydrocolloid on preliminary impression for edentulism

被引:1
作者
Maruo, Y
Irie, M
Nishigawa, G
Oka, M
Minagi, S
Suzuki, K
机构
[1] Okayama Univ, Grad Sch Med & Dent, Dept Occlusal & Oral Funct Rehabil, Okayama 7008525, Japan
[2] Okayama Univ, Grad Sch Med & Dent, Dept Biomat, Okayama 7008525, Japan
[3] Okayama Univ, Hosp Dent, Clin Div Removable Prosthodont, Okayama 7008525, Japan
关键词
irreversible hydrocolloid; edentulism; preliminary impression;
D O I
10.4012/dmj.23.395
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study aims to investigate the preferred viscosity of irreversible hydrocolloid used in the preliminary impression for edentulism. Thirteen modalities of irreversible hydrocolloid were prepared by changing the W/P ratio. Discrimination test for the preferred viscosity was performed on 11 prosthodontists (10.4 +/- 5.3 years of prosthetic experience). The parameter of discrimination test (P%) was calculated as the ratio of the number of adequate tests to the total number of tests. The P% and apparent viscosity coefficient (etaa) values measured by rheometer demonstrated good correlation (Y = -35.8X(2)+ 118.4X-22.8, r=0.86, p<0.01). Prosthodontists could judge the preferred viscosity based on their clinical experiences. On the preliminary impression for edentulism, the preferred viscosity demonstrated in vitro using a polyurethane maxilla model was 1.21 x 10(3) Pa.s.
引用
收藏
页码:395 / 398
页数:4
相关论文
共 15 条
  • [1] Arbree N S, 1996, J Prosthodont, V5, P219, DOI 10.1111/j.1532-849X.1996.tb00300.x
  • [2] Effect of processing variables (different compression packing processes and investment material types) and time on the dimensional accuracy of polymethyl methacrylate denture bases
    Baydas, S
    Bayindir, F
    Akyil, MS
    [J]. DENTAL MATERIALS JOURNAL, 2003, 22 (02) : 206 - 213
  • [3] Thermal and PH changes, and dimensional stability in irreversible hydrocolloid impression material during setting
    Bayindir, F
    Yanikoglu, N
    Duymus, Z
    [J]. DENTAL MATERIALS JOURNAL, 2002, 21 (02) : 200 - 209
  • [4] Effect of rinsing alginate impressions using acidic electrolyzed water on dimensional change and deformation of stone models
    Hiraguchi, H
    Nakagawa, H
    Uchida, H
    Tanabe, N
    [J]. DENTAL MATERIALS JOURNAL, 2003, 22 (04) : 494 - 506
  • [5] Survey of prosthodontic impression procedures for complete dentures in general dental practice in the United Kingdom
    Hyde, TP
    McCord, JF
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1999, 81 (03) : 295 - 299
  • [6] Consistency of alginate impression materials and their evaluation
    Inoue, K
    Song, YX
    Fujii, K
    Kadokawa, A
    Tanie, T
    [J]. JOURNAL OF ORAL REHABILITATION, 1999, 26 (03) : 203 - 207
  • [7] MAGNITUDE ESTIMATION AND SENSORY MATCHING
    MARKS, LE
    [J]. PERCEPTION & PSYCHOPHYSICS, 1988, 43 (06): : 511 - 525
  • [8] Effects of cyclic loading on viscoelastic properties of soft lining materials
    Muraoka, G
    Takahashi, H
    Hayakawa, I
    [J]. DENTAL MATERIALS JOURNAL, 2003, 22 (03) : 251 - 261
  • [9] Cytocompatibility of new phthalate ester-free tissue conditioners in vitro
    Nishijima, M
    Hashimoto, Y
    Nakamura, M
    [J]. DENTAL MATERIALS JOURNAL, 2002, 21 (02) : 118 - 132
  • [10] Setting properties of alginate impression materials in dynamic viscoelasticity
    Shigeto, N
    Yamada, Y
    Iwanaga, H
    Subianto, A
    Hamada, T
    [J]. JOURNAL OF ORAL REHABILITATION, 1997, 24 (10) : 761 - 765