Determination of trace levels of Cd(II) in tap water samples by anodic stripping voltammetry with an electrografted boron-doped diamond electrode

被引:10
作者
Innuphat, Chalermpol [1 ]
Chooto, Pipat [1 ]
机构
[1] Prince Songkla Univ, Fac Sci, Analyt Chem Div, Dept Chem, Hat Yai 90112, Songkhla, Thailand
来源
SCIENCEASIA | 2017年 / 43卷 / 01期
关键词
voltammetric analysis; ASV; Cd2+; CARBON-PASTE ELECTRODE; ELECTROCHEMICAL DETECTION; SILVER ELECTRODE; METAL-IONS; LEAD; CADMIUM; MERCURY; COPPER; FILM; MANGANESE;
D O I
10.2306/scienceasia1513-1874.2017.43.033
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A boron-doped diamond electrode modified by 0.5 mM 4-aminomethyl benzoic acid was used for electrochemical determination of Cd2+ in tap water samples by anodic stripping voltammetry. This method is based on the electrochemical reduction of 4-aminomethyl benzoic acid on the electrode followed by the determination of Cd2+ with a single well-defined reduction peak at 0.72 V versus Ag/AgC1 in acetate buffer solutions at pH 6.0. Optimal conditions were established with respect to electrode pretreatment, time accumulation, potential accumulation, scan rate, and pH. Accurate (r(2) = 0.9989, n = 6) calibration curves were obtained for Cd2+ concentrations ranging between 2 ppb and 50 ppb. Other dissolved metals (Ca, Mg, Zn, Mn, Fe, Cu, Al, Co, Pb, and Ni) have no interference on the Cd2+ calibration curves. The achieved detection limit was 0.2 ppb. High accuracy and reproducibility of the results as well as excellent stability of the electrode material proves superb capabilities of this Cd2+ detection system. Recovery in the range of 97-102% further confirmed the usefulness of the proposed method to analyse Cd2+ in tap water samples. The results with SRM1640 were in good agreement with those by inductively coupled plasma optical emission spectrometry.
引用
收藏
页码:33 / 41
页数:9
相关论文
共 41 条
[1]   Determination of lanthanides in magnesium alloys by ion chromatography [J].
AlShawi, AW ;
Dahl, R .
ANALYTICA CHIMICA ACTA, 1996, 333 (1-2) :23-30
[2]  
[Anonymous], 1965, J GEOL SOC AUST, DOI [DOI 10.1080/00167616508728596, 10.1080/00167616508728596]
[3]   The silver electrode in square-wave anodic stripping voltammetry. Determination of Pb2+ without removal of oxygen [J].
Brand, M ;
Eshkenazi, I ;
KirovaEisner, E .
ANALYTICAL CHEMISTRY, 1997, 69 (22) :4660-4664
[4]   Diazonium salt click chemistry based multiwall carbon nanotube electrocatalytic platforms [J].
Bravo, I. ;
Garcia-Mendiola, T. ;
Revenga-Parra, M. ;
Pariente, F. ;
Lorenzo, E. .
SENSORS AND ACTUATORS B-CHEMICAL, 2015, 211 :559-568
[5]   Determination of reduced glutathione using an amperometric carbon paste electrode chemically modified with TTF-TCNQ [J].
Calvo-Marzal, P ;
Chumbimuni-Torres, KY ;
Höehr, NF ;
Neto, GD ;
Kubota, LT .
SENSORS AND ACTUATORS B-CHEMICAL, 2004, 100 (03) :333-340
[6]   Determination of trace levels of Pb(II) in tap water by anodic stripping voltammetry with boron-doped diamond electrode [J].
Chooto, Pipat ;
Wararatananurak, Puchong ;
Innuphat, Chalermpol .
SCIENCEASIA, 2010, 36 (02) :150-156
[7]   Determination of linuron in water and vegetable samples using stripping voltammetry with a carbon paste electrode [J].
de Lima, F. ;
Cozzi, F. ;
Fiorucci, A. R. ;
Cardoso, C. A. L. ;
Arruda, G. J. ;
Ferreira, V. S. .
TALANTA, 2011, 83 (05) :1763-1768
[8]   Voltammetry determination of trace manganese with pretreatment glassy carbon electrode by linear sweep voltammetry [J].
Di, JW ;
Zhang, F .
TALANTA, 2003, 60 (01) :31-36
[9]   Determination of Cd2+ and Pb2+ on glassy carbon electrode modified by electrochemical reduction of aromatic diazonium salts [J].
Fan, Lishuang ;
Chen, Jiuan ;
Zhu, Shuyun ;
Wang, Min ;
Xu, Guobao .
ELECTROCHEMISTRY COMMUNICATIONS, 2009, 11 (09) :1823-1825
[10]   Highly sensitive detection of Cr6+ on boron doped diamond electrodes [J].
Fierro, Stephane ;
Watanabe, Takeshi ;
Akai, Kazumi ;
Einaga, Yasuaki .
ELECTROCHIMICA ACTA, 2012, 82 :9-11