Implementation of a GEANT4 Monte Carlo code for the development of a proton therapy beam line and verification of proton beams dose distributions

被引:0
|
作者
Cirrone, GAP
Cuttone, G
Pia, MG
Guatelli, S
Lo Nigro, S
Sabini, MG
Lo Nigro, S
机构
[1] Ist Nazl Fis Nucl, Lab Nazl Sud, I-95129 Catania, Italy
[2] Ist Nazl Fis Nucl, Sez Genova, Genoa, Italy
[3] Univ Catania, Dept Phys, Catania, Italy
关键词
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
引用
收藏
页码:S106 / S106
页数:1
相关论文
共 50 条
  • [1] Implementation of a new Monte Carlo - GEANT4 simulation tool for the development of a proton therapy beam line and verification of the related dose distributions
    Cirrone, GAP
    Cuttone, G
    Guatelli, S
    Lo Nigro, S
    Mascialino, B
    Pia, MG
    Raffaele, L
    Russo, G
    Sabini, MG
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (01) : 262 - 265
  • [2] Verification of the dose distributions with GEANT4 simulation for proton therapy
    Aso, T
    Kimura, A
    Tanaka, S
    Yoshida, H
    Kanematsu, N
    Sasaki, T
    Akagi, T
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2138 - 2142
  • [3] Verification of the dose distributions with GEANT4 simulation for proton therapy
    Aso, T
    Kimura, A
    Tanaka, S
    Yoshida, H
    Kanematsu, N
    Sasaki, T
    Akagi, T
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (04) : 896 - 901
  • [4] Implementation of a new Monte Carlo simulation tool for the development of a proton therapy beam line and verification of the related dose distributions
    Cirrone, GAP
    Cuttone, G
    Guatelli, S
    Lo Nigro, S
    Mascialino, B
    Pia, MG
    Raffaele, L
    Russo, G
    Sabini, MG
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1756 - 1758
  • [5] Pencil Beam Algorithm on the GEANT4 Based Simulation Framework and Verification of the Dose Distributions for Proton Therapy
    Aso, Tsukasa
    Yamashita, Tomohiro
    Akagi, Takashi
    Sasaki, Takashi
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2166 - +
  • [6] VERIFICATION OF A PROTON THERAPY FACILITY MONTE CARLO SIMULATION BASED ON THE GAMOS/GEANT4 FRAMEWORK
    Lagares, J. I.
    Arce, P.
    Terron, J. A.
    Nieto-Camero, J. J.
    Sansaloni, F.
    Korf, A.
    Romero Exposito, M. T.
    Nunez, L.
    Rodriguez, R.
    Loubser, M.
    Sanchez-Doblado, F.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S531 - S531
  • [7] Energy Distributions of Particles Generated for Proton Interactions in Water: A Simulation with GEANT4 Monte Carlo Code
    Chen, Y.
    Ahmad, S.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [8] Verification of the use of GEANT4 and MCNPX Monte Carlo codes for calculations of the depth-dose distributions in water for the proton therapy of eye tumours
    Grzadziel, Maigorzata
    Konefal, Adam
    Zipper, Wiktor
    Pietrzak, Robert
    Bzymek, Ewelina
    NUKLEONIKA, 2014, 59 (02) : 61 - 66
  • [9] Monte Carlo simulations in proton dosimetry with Geant4
    Moravek, Z
    Bogner, L
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S62 - S62
  • [10] Monte Carlo calculation of beam quality correction factors in proton beams using TOPAS/GEANT4
    Baumann, Kilian-Simon
    Kaupa, Sina
    Bach, Constantin
    Engenhart-Cabillic, Rita
    Zink, Klemens
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (05):