Improved osseointeraction of calcium phosphate-coated external fixation pins - Studies in calves

被引:10
|
作者
Anderson, DE
St-Jean, G
Richardson, DC
DeBowes, RM
Roush, JK
Lowry, SR
Toll, PW
Aberman, HM
Van Sickle, DC
Hoskinson, JJ
机构
[1] Kansas State Univ, Coll Vet Med, Dept Clin Sci, Manhattan, KS 66506 USA
[2] Mark Morris Inst, Topeka, KS USA
[3] Howmedica Inc, Pfizer Hosp Prod Grp, Rutherford, NJ USA
[4] Purdue Univ, Sch Vet Med, Dept Basic Med Sci, W Lafayette, IN 47907 USA
来源
ACTA ORTHOPAEDICA SCANDINAVICA | 1997年 / 68卷 / 06期
关键词
D O I
10.3109/17453679708999029
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We investigated osseointeraction of solution-precipitated calcium phosphate (SPCP)-coated transfixation pins used in external skeletal fixation of a calf stable fracture model, One group (SPCP) received centrally-threaded transfixation pins which had SPCP coating; the other group (control) received identical, but not coated, pins, Radiographs were obtained 1 and 40 days after surgery and examined for evidence of osteolysis, Bone phase Tc-99m-MDP studies were performed 6 and 28 days after surgery. Calves were killed 40 days after surgery and mechanical tests performed, Dual-energy x-ray absorptiometry (DEXA) and histomorphometric analyses were done, A smaller proportion of SPCP pins (5/24) had evidence of discharge during the study com- pared with control pins (21/24), A smaller proportion of SPCP pins (4%) had radiographic evidence of osteolysis compared with control pins (42%), Uptake of Tc-99m-MDP was similar for SPCP and control carves, Uptake was significantly greater in bone segments showing radiographic evidence of osteolysis than in bone segments not having osteolysis. Yield stress (MPa) for axial displacement was similar in the treatment groups. Bone mineral density was less in SPCP pins, Affinity index and interface histologic score were greater and osteoclastic index less in SPCP calves, Coating of transfixation pins with solution-precipitated calcium phosphate improved the osseointeraction of pin and bone during this 40-day study.
引用
收藏
页码:571 / 576
页数:6
相关论文
共 50 条
  • [41] Enhanced gap filling and osteoconduction associated with alendronate-calcium phosphate-coated porous tantalum
    Garbuz, Donald S.
    Hu, Youxin
    Kim, Winston Y.
    Duan, Ke
    Masri, Bassam A.
    OxIand, Thomas R.
    Burt, Helen
    Wang, Rizhi
    Duncan, Clive P.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (05): : 1090 - 1100
  • [42] Osteoblast proliferation on neat and apatite-like calcium phosphate-coated titanium foam scaffolds
    Jalota, Sahil
    Bhaduri, Sarit B.
    Tas, A. Cuneyt
    MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2007, 27 (03): : 432 - 440
  • [43] Hydroxyapatite-coated external fixation pins in severe wartime fractures: risk factors for loosening
    Gwinn, David E.
    Keeling, John J.
    Andersen, Romney C.
    McGuigan, Francis X.
    CURRENT ORTHOPAEDIC PRACTICE, 2010, 21 (01): : 54 - 59
  • [44] Clinical benefit of hydroxyapatite-coated pins compared with stainless steel pins in external fixation at the wrist: A randomised prospective study
    Pieske, Oliver
    Kaltenhauser, Felicitas
    Pichlmaier, Leopold
    Schramm, Nicolai
    Trentzsch, Heiko
    Loeffler, Thomas
    Greiner, Axel
    Piltz, Stefan
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2010, 41 (10): : 1031 - 1036
  • [45] Prevention of pin track infection in external fixation with silver coated pins: Clinical and microbiological results
    Masse, A
    Bruno, A
    Bosetti, M
    Biasibetti, A
    Cannas, M
    Gallinaro, P
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2000, 53 (05): : 600 - 604
  • [46] Prospective Observational Study of the Early Loading of Nanostructured Calcium Phosphate-Coated Tapered Implants in the Mandible and Maxilla
    Kim, Young-Kyun
    Yun, Pil-Young
    Kim, Sung-Bum
    Ahn, Kyo-Jin
    Lee, Hyo-Jung
    Yi, Yang-Jin
    Kim, Su-Gwan
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2014, 34 (05) : 695 - 703
  • [47] Biocompatibility of calcium phosphate-coated and of geometrically structured nickel-titanium (NiTi) by in vitro testing methods
    Bogdanski, D
    Epple, M
    Esenwein, SA
    Muhr, G
    Petzoldt, V
    Prymak, O
    Weinert, K
    Köller, M
    MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2004, 378 (1-2): : 527 - 531
  • [48] Inhibitory effect of calcium phosphate-coated high-affinity liposomes on Staphylococcus aureus and its biofilms
    Lin, Lin
    Zhang, Pin
    Li, Changzhu
    Hua, Zichun
    Cui, Haiying
    FOOD BIOSCIENCE, 2022, 50
  • [49] Influence of electrochemical parameters on the characteristics of sono-electrodeposited calcium phosphate-coated carbon fiber cloth
    Olivier, F.
    Picard, Q.
    Delpeux-Ouldriane, S.
    Chancolon, J.
    Warmont, F.
    Sarou-Kanian, V
    Fayon, F.
    Bonnamy, S.
    SURFACE & COATINGS TECHNOLOGY, 2020, 389
  • [50] Intraoperative loading of calcium phosphate-coated implants with gentamicin prevents experimental Staphylococcus aureus infection in vivo
    Thompson, Keith
    Petkov, Stoyan
    Zeiter, Stephan
    Sprecher, Christoph M.
    Richards, R. Geoff
    Moriarty, T. Fintan
    Eijer, Henk
    PLOS ONE, 2019, 14 (02):