Improved osseointeraction of calcium phosphate-coated external fixation pins - Studies in calves

被引:10
|
作者
Anderson, DE
St-Jean, G
Richardson, DC
DeBowes, RM
Roush, JK
Lowry, SR
Toll, PW
Aberman, HM
Van Sickle, DC
Hoskinson, JJ
机构
[1] Kansas State Univ, Coll Vet Med, Dept Clin Sci, Manhattan, KS 66506 USA
[2] Mark Morris Inst, Topeka, KS USA
[3] Howmedica Inc, Pfizer Hosp Prod Grp, Rutherford, NJ USA
[4] Purdue Univ, Sch Vet Med, Dept Basic Med Sci, W Lafayette, IN 47907 USA
来源
ACTA ORTHOPAEDICA SCANDINAVICA | 1997年 / 68卷 / 06期
关键词
D O I
10.3109/17453679708999029
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We investigated osseointeraction of solution-precipitated calcium phosphate (SPCP)-coated transfixation pins used in external skeletal fixation of a calf stable fracture model, One group (SPCP) received centrally-threaded transfixation pins which had SPCP coating; the other group (control) received identical, but not coated, pins, Radiographs were obtained 1 and 40 days after surgery and examined for evidence of osteolysis, Bone phase Tc-99m-MDP studies were performed 6 and 28 days after surgery. Calves were killed 40 days after surgery and mechanical tests performed, Dual-energy x-ray absorptiometry (DEXA) and histomorphometric analyses were done, A smaller proportion of SPCP pins (5/24) had evidence of discharge during the study com- pared with control pins (21/24), A smaller proportion of SPCP pins (4%) had radiographic evidence of osteolysis compared with control pins (42%), Uptake of Tc-99m-MDP was similar for SPCP and control carves, Uptake was significantly greater in bone segments showing radiographic evidence of osteolysis than in bone segments not having osteolysis. Yield stress (MPa) for axial displacement was similar in the treatment groups. Bone mineral density was less in SPCP pins, Affinity index and interface histologic score were greater and osteoclastic index less in SPCP calves, Coating of transfixation pins with solution-precipitated calcium phosphate improved the osseointeraction of pin and bone during this 40-day study.
引用
收藏
页码:571 / 576
页数:6
相关论文
共 50 条
  • [31] Hydroxyapatite-Coated Pins Versus Titanium Alloy Pins in External Fixation at the Wrist: A Controlled Cohort Study
    Pieske, Oliver
    Pichlmaier, Leopold
    Kaltenhauser, Felicitas
    Schramm, Nicolai
    Rubenbauer, Bianka
    Greiner, Axel
    Piltz, Stefan
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2011, 70 (04): : 845 - 851
  • [32] Biological responses of osteoblastic HOS cells to titanium- and calcium phosphate-coated films
    Mo, MJ
    Kim, SU
    Shin, HY
    Im, DS
    Jung, IH
    Ko, JS
    Lee, WK
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2005, 11 (04) : 507 - 514
  • [33] Macroporous and nanofibrous PLLA scaffolds reinforced with calcium phosphate-coated multiwalled carbon nanotubes
    Cai, Qing
    Mao, Jifu
    Li, Xiaoli
    Yang, Xiaoping
    MATERIALS LETTERS, 2014, 128 : 238 - 241
  • [34] Degradable Calcium Phosphate-Coated Upconversion Nanoparticles for Highly Efficient Chemo-Photodynamic Therapy
    Liu, Shikai
    Li, Wenting
    Dong, Shuming
    Gai, Shili
    Dong, Yushan
    Yang, Dan
    Dai, Yunlu
    He, Fei
    Yang, Piaoping
    ACS APPLIED MATERIALS & INTERFACES, 2019, 11 (51) : 47659 - 47670
  • [35] Hydroxyapatite and tricalcium phosphate-coated cups with and without screw fixation -: A randomized study of 64 hips
    Thanner, J
    Kärrholm, J
    Herberts, P
    Malchau, H
    JOURNAL OF ARTHROPLASTY, 2000, 15 (04): : 405 - 412
  • [36] SCANNING ELECTRON-MICROSCOPY STUDIES OF CERAMIC LAYERS AND INTERFACIAL REGIONS FOR CALCIUM PHOSPHATE-COATED TITANIUM DENTAL IMPLANTS
    BRANTLEY, WA
    TUFEKCI, E
    MITCHELL, JC
    FOREMAN, DW
    MCGLUMPHY, EA
    CELLS AND MATERIALS, 1995, 5 (01): : 73 - 82
  • [37] Antimicrobial peptides on calcium phosphate-coated titanium for the prevention of implant-associated infections
    Kazemzadeh-Narbat, Mehdi
    Kindrachuk, Jason
    Duan, Ke
    Jenssen, Havard
    Hancock, Robert E. W.
    Wang, Rizhi
    BIOMATERIALS, 2010, 31 (36) : 9519 - 9526
  • [38] A biomechanical and histological analysis of standard versus hydroxyapatite-coated pins for external fixation
    Moroni, Antonio
    Cadossi, Matteo
    Romagnoli, Matteo
    Faldini, Cesare
    Giannini, Sandro
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2008, 86B (02) : 417 - 421
  • [39] Adhesion of bacteria to stainless steel and silver-coated orthopedic external fixation pins
    Wassall, MA
    Santin, M
    Isalberti, C
    Cannas, M
    Denyer, SP
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1997, 36 (03): : 325 - 330
  • [40] Evaluation of a Novel Calcium Phosphate-Coated Titanium Porous Oxide Implant Surface: A Study in Rabbits
    Poulos, Nicholas M.
    Rodriguez, Nancy A.
    Lee, Jaebum
    Rueggeberg, Frederick A.
    Schuepbach, Peter
    Hall, Jan
    Susin, Cristiano
    Wikesjoe, Ulf M. E.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (04) : 731 - 738