Semi-automated counting method of axons in transmission electron microscopic images

被引:14
作者
Kim, Chan Yun [1 ]
Rho, Seungsoo [2 ]
Lee, Naeun [1 ]
Lee, Chang-Kyu [1 ]
Sung, Youngje [2 ]
机构
[1] Yonsei Univ, Coll Med, Dept Ophthalmol, Inst Vis Res, Seoul, South Korea
[2] CHA Univ, CHA Bundang Med Ctr, Dept Ophthalmol, 59 Yatap Ro, Songnam 463712, Gyeonggi Do, South Korea
关键词
axon; experimental model; glaucoma; ocular hypertension semi-automated counting; transmission electron microscopy; OPTIC-NERVE; RAT MODEL; QUANTITATIVE-ANALYSIS; GLAUCOMA; PRESSURE; DAMAGE;
D O I
10.1111/vop.12247
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective To evaluate the accuracy of a new semi-automated method for counting axons in transmission electron microscopic (TEM) images. Procedures Optic nerve cross sections were obtained from both eyes of Sprague Dawley rats after unilateral induction of chronic ocular hypertension. TEM images (30009 magnification) of cross sections were evaluated by both semi-automated and manual counting methods. The semi-automated counting method was performed using IMAGEJ software after simple image optimization, and the resulting estimate of axon damage was compared with semiquantitative damage grading scale from light microscopic (LM) images. Results Axon counts obtained from the semi-automated method were strongly correlated with those obtained from the manual counting method (Pearson's correlation coefficient r = 0.996, P < 0.001) and from the full manual count from LM images (Spearman's q = 0.973, P < 0.001). The semi-automated method measured axonal damage with an error of 0.94 +/- 3.16% (mean +/- standard deviation), with worse axonal damage associated with greater error. Interobserver and intra-observer variability in axons counts were low (Spearman's q = 0.999, P < 0.005). The results of the semi-automated counting method were highly correlated with semiquantitative damage grading scale (Spearman's q = 0.965, P < 0.001). Conclusion Results of our semi-automated method for counting axons in TEM images were strongly correlated with those of conventional counting methods and showed excellent reproducibility.
引用
收藏
页码:29 / 37
页数:9
相关论文
共 22 条
[1]   Quantifying optic nerve axons in a cat glaucoma model by a semi-automated targeted counting method [J].
Teixeira, Leandro B. C. ;
Buhr, Kevin A. ;
Bowie, Owen ;
Duke, Felicia D. ;
Nork, T. Michael ;
Dubielzig, Richard R. ;
McLellan, Gillian J. .
MOLECULAR VISION, 2014, 20 :376-385
[2]   Automated and semi-automated enhancement, segmentation and tracing of cytoskeletal networks in microscopic images: A review [J].
Oezdemir, Bugra ;
Reski, Ralf .
COMPUTATIONAL AND STRUCTURAL BIOTECHNOLOGY JOURNAL, 2021, 19 :2106-2120
[3]   A semi-automated technique for labeling and counting of apoptosing retinal cells [J].
Mukhtar Bizrah ;
Steve C Dakin ;
Li Guo ;
Farzana Rahman ;
Miles Parnell ;
Eduardo Normando ;
Shereen Nizari ;
Benjamin Davis ;
Ahmed Younis ;
M Francesca Cordeiro .
BMC Bioinformatics, 15
[4]   A semi-automated method for identifying and measuring myelinated nerve fibers in scanning electron microscope images [J].
More, Heather L. ;
Chen, Jingyun ;
Gibson, Eli ;
Donelan, J. Maxwell ;
Beg, Mirza Faisal .
JOURNAL OF NEUROSCIENCE METHODS, 2011, 201 (01) :149-158
[5]   A semi-automated technique for labeling and counting of apoptosing retinal cells [J].
Bizrah, Mukhtar ;
Dakin, Steve C. ;
Guo, Li ;
Rahman, Farzana ;
Parnell, Miles ;
Normando, Eduardo ;
Nizari, Shereen ;
Davis, Benjamin ;
Younis, Ahmed ;
Cordeiro, M. Francesca .
BMC BIOINFORMATICS, 2014, 15
[6]   Automated Quantification of Optic Nerve Axons in Primate Glaucomatous and Normal Eyes-Method and Comparison to Semi-Automated Manual Quantification [J].
Reynaud, Juan ;
Cull, Grant ;
Wang, Lin ;
Fortune, Brad ;
Gardiner, Stuart ;
Burgoyne, Claude F. ;
Cioffi, George A. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (06) :2951-2959
[8]   An interactive ImageJ plugin for semi-automated image denoising in electron microscopy [J].
Roels, Joris ;
Vernaillen, Frank ;
Kremer, Anna ;
Goncalves, Amanda ;
Aelterman, Jan ;
Luong, Hiep Q. ;
Goossens, Bart ;
Philips, Wilfried ;
Lippens, Saskia ;
Saeys, Yvan .
NATURE COMMUNICATIONS, 2020, 11 (01)
[9]   A rapid, semi-automated method for scoring micronuclei in mononucleated mouse lymphoma cells [J].
Doherty, Ann T. ;
Hayes, Julie ;
Fellows, Mick ;
Kirk, Sarah ;
O'Donovan, Mike .
MUTATION RESEARCH-GENETIC TOXICOLOGY AND ENVIRONMENTAL MUTAGENESIS, 2011, 726 (01) :36-41
[10]   Retinal Vessel Diameter Assessment in Papilledema by Semi-Automated Analysis of SLO Images: Feasibility and Reliability [J].
Moss, Heather E. ;
Treadwell, Gillian ;
Wanek, Justin ;
DeLeon, Sherryl ;
Shahidi, Mahnaz .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (04) :2049-2054