Semi-automated counting method of axons in transmission electron microscopic images

被引:14
作者
Kim, Chan Yun [1 ]
Rho, Seungsoo [2 ]
Lee, Naeun [1 ]
Lee, Chang-Kyu [1 ]
Sung, Youngje [2 ]
机构
[1] Yonsei Univ, Coll Med, Dept Ophthalmol, Inst Vis Res, Seoul, South Korea
[2] CHA Univ, CHA Bundang Med Ctr, Dept Ophthalmol, 59 Yatap Ro, Songnam 463712, Gyeonggi Do, South Korea
关键词
axon; experimental model; glaucoma; ocular hypertension semi-automated counting; transmission electron microscopy; OPTIC-NERVE; RAT MODEL; QUANTITATIVE-ANALYSIS; GLAUCOMA; PRESSURE; DAMAGE;
D O I
10.1111/vop.12247
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective To evaluate the accuracy of a new semi-automated method for counting axons in transmission electron microscopic (TEM) images. Procedures Optic nerve cross sections were obtained from both eyes of Sprague Dawley rats after unilateral induction of chronic ocular hypertension. TEM images (30009 magnification) of cross sections were evaluated by both semi-automated and manual counting methods. The semi-automated counting method was performed using IMAGEJ software after simple image optimization, and the resulting estimate of axon damage was compared with semiquantitative damage grading scale from light microscopic (LM) images. Results Axon counts obtained from the semi-automated method were strongly correlated with those obtained from the manual counting method (Pearson's correlation coefficient r = 0.996, P < 0.001) and from the full manual count from LM images (Spearman's q = 0.973, P < 0.001). The semi-automated method measured axonal damage with an error of 0.94 +/- 3.16% (mean +/- standard deviation), with worse axonal damage associated with greater error. Interobserver and intra-observer variability in axons counts were low (Spearman's q = 0.999, P < 0.005). The results of the semi-automated counting method were highly correlated with semiquantitative damage grading scale (Spearman's q = 0.965, P < 0.001). Conclusion Results of our semi-automated method for counting axons in TEM images were strongly correlated with those of conventional counting methods and showed excellent reproducibility.
引用
收藏
页码:29 / 37
页数:9
相关论文
共 22 条
  • [1] Quantifying optic nerve axons in a cat glaucoma model by a semi-automated targeted counting method
    Teixeira, Leandro B. C.
    Buhr, Kevin A.
    Bowie, Owen
    Duke, Felicia D.
    Nork, T. Michael
    Dubielzig, Richard R.
    McLellan, Gillian J.
    MOLECULAR VISION, 2014, 20 : 376 - 385
  • [2] Automated and semi-automated enhancement, segmentation and tracing of cytoskeletal networks in microscopic images: A review
    Oezdemir, Bugra
    Reski, Ralf
    COMPUTATIONAL AND STRUCTURAL BIOTECHNOLOGY JOURNAL, 2021, 19 : 2106 - 2120
  • [3] A semi-automated method for identifying and measuring myelinated nerve fibers in scanning electron microscope images
    More, Heather L.
    Chen, Jingyun
    Gibson, Eli
    Donelan, J. Maxwell
    Beg, Mirza Faisal
    JOURNAL OF NEUROSCIENCE METHODS, 2011, 201 (01) : 149 - 158
  • [4] A semi-automated technique for labeling and counting of apoptosing retinal cells
    Bizrah, Mukhtar
    Dakin, Steve C.
    Guo, Li
    Rahman, Farzana
    Parnell, Miles
    Normando, Eduardo
    Nizari, Shereen
    Davis, Benjamin
    Younis, Ahmed
    Cordeiro, M. Francesca
    BMC BIOINFORMATICS, 2014, 15
  • [5] A semi-automated technique for labeling and counting of apoptosing retinal cells
    Mukhtar Bizrah
    Steve C Dakin
    Li Guo
    Farzana Rahman
    Miles Parnell
    Eduardo Normando
    Shereen Nizari
    Benjamin Davis
    Ahmed Younis
    M Francesca Cordeiro
    BMC Bioinformatics, 15
  • [6] Automated Quantification of Optic Nerve Axons in Primate Glaucomatous and Normal Eyes-Method and Comparison to Semi-Automated Manual Quantification
    Reynaud, Juan
    Cull, Grant
    Wang, Lin
    Fortune, Brad
    Gardiner, Stuart
    Burgoyne, Claude F.
    Cioffi, George A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (06) : 2951 - 2959
  • [8] An interactive ImageJ plugin for semi-automated image denoising in electron microscopy
    Roels, Joris
    Vernaillen, Frank
    Kremer, Anna
    Goncalves, Amanda
    Aelterman, Jan
    Luong, Hiep Q.
    Goossens, Bart
    Philips, Wilfried
    Lippens, Saskia
    Saeys, Yvan
    NATURE COMMUNICATIONS, 2020, 11 (01)
  • [9] A rapid, semi-automated method for scoring micronuclei in mononucleated mouse lymphoma cells
    Doherty, Ann T.
    Hayes, Julie
    Fellows, Mick
    Kirk, Sarah
    O'Donovan, Mike
    MUTATION RESEARCH-GENETIC TOXICOLOGY AND ENVIRONMENTAL MUTAGENESIS, 2011, 726 (01) : 36 - 41
  • [10] Retinal Vessel Diameter Assessment in Papilledema by Semi-Automated Analysis of SLO Images: Feasibility and Reliability
    Moss, Heather E.
    Treadwell, Gillian
    Wanek, Justin
    DeLeon, Sherryl
    Shahidi, Mahnaz
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (04) : 2049 - 2054