Modeling and estimation of the optimal tilt angle, maximum incident solar radiation, and global radiation index of the photovoltaic system

被引:31
作者
Obiwulu, Anthony Umunnakwe [1 ]
Erusiafe, Nald [1 ]
Olopade, Muteeu Abayomi [1 ]
Nwokolo, Samuel Chukwujindu [2 ]
机构
[1] Univ Lagos, Fac Sci, Dept Phys, Lagos, Nigeria
[2] Univ Calabar, Fac Phys Sci, Dept Phys, Calabar, Nigeria
基金
美国国家航空航天局;
关键词
Optimum tilt angle; Global radiation index; Maximum incident solar radiation; Orientation; Global solar radiation; AZIMUTH ANGLES; COLLECTORS; DIFFUSE; IRRADIANCE; OPTIMIZATION; ORIENTATION; PERFORMANCE; SURFACES; SHADOW; PANELS;
D O I
10.1016/j.heliyon.2022.e09598
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This research was designed to apply measured and theoretically derived models to estimate the optimal tilt angle (beta), maximum incident solar radiation (H-T), and global radiation index (GRI) in Lagos and 37 metropolitan cities in Nigeria. Six modules were mounted at different tilt angles with two modules north-facing, three south-facing, and one positioned horizontally to determine the orientation and tilt angle performance. Overall, the 16.8 module 4 south-facing tilted emerged as the best performing module for H-T, with maximum output power, and much more than 6.174 annual earned energy reported on module 6 mounted horizontally. The GRI obtained from the six solar modules revealed a significant coefficient of 1.0269 for module 1 north-facing, 0.9923 for module 2 north-facing, 1.0217 for module 3 south-facing, 0.9609 for module 4 south-facing, and 1.0232 for module 5 south-facing for the values obtained from the horizontally positioned module 6. In-depth statistical analysis of the effectiveness of values observed against the predicted values to estimate the optimal and maximum inclination angle of incident solar radiation using error metrics and GPI revealed that model 5, model 12, model 14, model 17, and model 14 outperform the other estimation models in their respective categories. A similar statistical analysis of model 14 with the best performance was performed to estimate the best inclination angle in 37 metropolitan cities in Nigeria compared to two models consolidated in the literature; model 14 performed admirably in terms of accuracy compared to the two models obtained from the literature.
引用
收藏
页数:27
相关论文
共 71 条
  • [1] Employing convex shape absorber for enhancing the performance of solar still desalination system
    Abdullah, A. S.
    Omara, Z. M.
    Bacha, Habib Ben
    Younes, M. M.
    [J]. JOURNAL OF ENERGY STORAGE, 2022, 47
  • [2] Numerical and experimental analysis of the tilt angle's effects on the characteristics of the melting process of PCM-based as PV cell's backside heat sink
    Abdulmunem, Abdulmunem R.
    Samin, Pakharuddin Mohd
    Rahman, Hasimah Abdul
    Hussien, Hashim A.
    Mazali, Izhari Izmi
    Ghazali, Habibah
    [J]. RENEWABLE ENERGY, 2021, 173 : 520 - 530
  • [3] Ajao K.R., 2013, Journal of Engineering Science and Technology Review, V6, P87
  • [4] Theoretical and experimental investigation of photovoltaic cell performance, with optimum tilted angle: Basra city case study
    Al-Sayyab, Ali K. Shaker
    Al Tmari, Zainab Y.
    Taher, Maher K.
    [J]. CASE STUDIES IN THERMAL ENGINEERING, 2019, 14
  • [5] Optimization and techno-economic assessment of rooftop photovoltaic system
    Awan, Ahmed Bilal
    [J]. JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2019, 11 (03)
  • [6] Ayodele T. R., 2018, International Journal of Renewable Energy Technology, V9, P453
  • [7] Babatunde O, 2018, RENEW ENERG FOCUS, V24, P16, DOI 10.1016/j.ref.2017.10.005
  • [8] Analysis of the tilt and azimuth angles of photovoltaic systems in non-ideal positions for urban applications
    Barbon, A.
    Bayon-Cueli, C.
    Bayon, L.
    Rodriguez-Suanzes, C.
    [J]. APPLIED ENERGY, 2022, 305
  • [9] Barbon A., 2022, APPL ENERG
  • [10] Behar O., 2015, ENERGY CONVERS MANAG