NONLINEAR THERMAL MODELING OF INDOOR AND OUTDOOR OIL-IMMERSED POWER TRANSFORMERS

被引:0
|
作者
Iskender, Ires [1 ]
Mamizadeh, Ali [1 ]
机构
[1] Gazi Univ, Engn & Architecture Fac, Dept Elect & Elect Engn, TR-06570 Maltepe, Turkey
关键词
oil immersed transformers; thermal model; indoor; outdoor;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Transformers are the largest part of the investments of transmission and distribution systems and have a considerable economic impact on the operation of an electrical network. It is advisable to know the insulation condition, operating life, and loading capacitance of a transformer to ensure its economical operation and secured service. The most important parameter in transformers life expectancy is the insulation temperature level which accelerates the rate of aging of the insulation. In this study, the top-oil temperature is studied both for indoor and outdoor transformers and the thermal models proposed for them are compared. Since the thermal transfer is different for indoor and outdoor transformers considering their operating conditions, their thermal models differ from each other. In this study, the top-oil temperature is analyzed for indoor and outdoor transformers and the proposed thermal models are verified by the results obtained from the experiments carried out on different operating conditions.
引用
收藏
页码:321 / 327
页数:7
相关论文
共 50 条
  • [21] THE DEVELOPMENT OF AN OIL-IMMERSED SURGE ARRESTER FOR DISTRIBUTION TRANSFORMERS
    MCMILLEN, CJ
    COMBER, MG
    HOPKINSON, RH
    SCHOENDUBE, CW
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1985, 104 (09): : 2482 - 2491
  • [23] A review of temperature prediction methods for oil-immersed transformers
    Guo, Yi
    Chang, Yuan
    Lu, Bing
    MEASUREMENT, 2025, 239
  • [24] The Improved Thermal-circuit Model for hot-spot temperature calculation of Oil-immersed Power Transformers
    Wei Ben-gang
    Fu Chen-zhao
    Li Hong-lei
    Li Ke-jun
    Liang Yong-liang
    2016 IEEE INFORMATION TECHNOLOGY, NETWORKING, ELECTRONIC AND AUTOMATION CONTROL CONFERENCE (ITNEC), 2016, : 809 - 813
  • [25] An improved nonlinear thermal model for MV/LV prefabricated oil-immersed power transformer substations
    Ires Iskender
    Ali Mamizadeh
    Electrical Engineering, 2011, 93 : 9 - 22
  • [26] An improved nonlinear thermal model for MV/LV prefabricated oil-immersed power transformer substations
    Iskender, Ires
    Mamizadeh, Ali
    ELECTRICAL ENGINEERING, 2011, 93 (01) : 9 - 22
  • [27] Investigating Aging Characteristics of Oil-Immersed Power Transformers' Insulation in Electrical-Thermal-Mechanical Combined Conditions
    Yuan, Zonghui
    Wang, Qian
    Ren, Zhigang
    Lv, Fangcheng
    Xie, Qin
    Geng, Jianghai
    Zhu, Jianhao
    Teng, Fuyun
    POLYMERS, 2023, 15 (21)
  • [28] RELIABILITY OF OUTDOOR HIGH-VOLTAGE OIL-IMMERSED INSTRUMENT TRANSFORMERS UNDER EARTHQUAKE CONDITIONS.
    Spaeck, Helmut
    Siemens power engineering, 1983, 5 (05): : 255 - 259
  • [29] 3D modeling of winding hot spot temperature in oil-immersed transformers
    Reza Kebriti
    S. M. Hassan Hossieni
    Electrical Engineering, 2022, 104 : 3325 - 3338
  • [30] Probabilistic Modeling of Dissolved Gas Concentration for Predicting Operating Status of Oil-Immersed Transformers
    Shao, Jianwei
    Wang, Junhua
    Pan, Xiao
    Wang, Ruilin
    Liu, Shuxun
    Jin, Zhanxiang
    Wang, Ziqing
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2025, 21 (02) : 1339 - 1348