Effect of Pulsed Corona Discharge Voltage and Feed Gas Flow Rate on Dissolved Ozone Concentration

被引:1
|
作者
Prasetyaningrum, A. [1 ]
Ratnawati [1 ]
Jos, B. [1 ]
机构
[1] Diponegoro Univ, Fac Engn, Dept Chem Engn, Jl Prof H Soedarto Tembalang, Semarang 50276, Central Java, Indonesia
来源
INTERNATIONAL CONFERENCE OF CHEMICAL AND MATERIAL ENGINEERING (ICCME) 2015: GREEN TECHNOLOGY FOR SUSTAINABLE CHEMICAL PRODUCTS AND PROCESSES | 2015年 / 1699卷
关键词
Corona discharge; Feed gas; Dissolved ozone; GENERATION;
D O I
10.1063/1.4938364
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Ozonization is one of the methods extensively used for water purification and degradation of organic materials. Ozone (O-3) is recognized as a powerful oxidizing agent. Due to its strong oxidability and better environmental friendless, ozone increasing being used in domestic and industrial applications. Current technology in ozone production utilizes several techniques (corona discharge, ultra violet radiation and electrolysis). This experiment aimed to evaluating effect of voltage and gas flow rate on ozone production with corona discharge. The system consists of two net-type stainless steel electrode placed in a dielectric barrier. Three pulsed voltage (20, 30, 40 KV) and flow rate (5, 10, 15 L/min) were prepare for operation variable at high frequency (3.7 kHz) with AC pulsed power supply. The dissolved ozone concentration depends on the applied high-voltage level, gas flow rate and the discharge exposure duration. The ozone concentration increases with decreasing gas flow rate. Dissolved ozone concentrations greater than 200 ppm can be obtained with a minimum voltage 40 kV.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Influence of dissolved inorganic additives on decomposition of phenol and acetic acid in water by direct contact of gas corona discharge
    Sano, N
    Fujimoto, T
    Kawashima, T
    Yamamoto, D
    Kanki, T
    Toyoda, A
    SEPARATION AND PURIFICATION TECHNOLOGY, 2004, 37 (02) : 169 - 175
  • [32] Modeling of DC corona discharge along an electrically conductive flat plate with gas flow
    Colver, GM
    El-Khabiry, S
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1999, 35 (02) : 387 - 394
  • [33] A New Detection Method for Corona Discharge in High Voltage Power Modules Based on Decomposition Gas Analysis
    Li Kang
    Wan Liujie
    Zhang Guoqiang
    2018 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2018, : 3123 - 3128
  • [34] Effect of air flow on corona discharge in wire-to-plate electrostatic precipitator
    Said, H. Ait
    Nouri, H.
    Zebboudj, Y.
    JOURNAL OF ELECTROSTATICS, 2015, 73 : 19 - 25
  • [35] Change of characteristics of desulfurization and denitrification by combustion flue gas composition and electrode configuration under pulsed corona discharge
    Kato, K
    Kasuga, Y
    Fujiwara, M
    Onda, K
    ELECTRICAL ENGINEERING IN JAPAN, 1996, 116 (04) : 94 - 108
  • [36] Removal of Organic Dye by High-Voltage Pulsed Streamer Discharge in Gas Bubbling Water
    Ruma
    Nagaoka, H.
    Yoshihara, K.
    Hosseini, S. H. R.
    Sakugawa, T.
    Akiyama, H.
    2014 9TH INTERNATIONAL FORUM ON STRATEGIC TECHNOLOGY (IFOST), 2014, : 516 - 518
  • [37] The Effect of Applied-voltage on Photon-Number of Corona Discharge on Transmission Lines Defect
    Wan Shuwei
    Zhao Xuesong
    Guo Xinyang
    Chen Lan
    Bian Xingming
    Yao Wenjun
    MacAlpine, Mark
    Wang Liming
    Guan Zhicheng
    2013 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2013, : 311 - 314
  • [38] Decomposition of aqueous phenol by direct contact of gas corona discharge with water: The influence of current density and applied voltage
    Sano, N
    Yamamoto, D
    Nakao, M
    Kanki, T
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 2004, 37 (11) : 1319 - 1325
  • [39] The Study of Different Metals Effect on Ozone Generation Under Corona Discharge in MV Switchgear Used for Fault Diagnostic
    Javed, Hassan
    Kang, Li
    Zhang, Guoqiang
    2019 IEEE ASIA POWER AND ENERGY ENGINEERING CONFERENCE (APEEC 2019), 2019, : 29 - 33
  • [40] Effect of TiO2 and Reverse Air Supply on Ozone Production of Negative Corona Discharge with the Needle in the Dielectric Tube to Mesh Electrode System
    Pekarek, Stanislav
    PLASMA CHEMISTRY AND PLASMA PROCESSING, 2015, 35 (04) : 705 - 719