Oxygen contamination in liquid Argon: combined effects on ionization electron charge and scintillation light

被引:50
作者
Acciarri, R. [1 ,2 ]
Antonello, M. [1 ,2 ,3 ]
Baibussinov, B. [4 ]
Baldo-Ceolin, M. [5 ,6 ]
Benetti, P. [7 ,8 ]
Calaprice, F. [9 ]
Calligarich, E. [10 ]
Cambiaghi, M. [7 ,8 ]
Canci, N. [1 ,2 ]
Carbonara, F. [11 ,12 ]
Cavanna, F. [1 ,2 ]
Centro, S. [5 ,6 ]
Cocco, A. G. [13 ]
Di Pompeo, F. [1 ,2 ,3 ]
Fiorillo, G. [11 ,12 ]
Galbiati, C. [9 ]
Gallo, V. [13 ]
Grandi, L. [1 ,2 ,3 ]
Meng, G. [4 ]
Modena, I. [1 ,2 ]
Montanari, C. [10 ]
Palamara, O. [3 ]
Pandola, L. [3 ]
Mortari, G. B. Piano [1 ,2 ]
Pietropaolo, F. [4 ]
Raselli, G. L. [10 ]
Roncadelli, M. [10 ]
Rossella, M. [10 ]
Rubbia, C. [3 ]
Segreto, E. [3 ]
Szelc, A. M. [1 ,2 ,14 ]
Tortorici, F. [3 ]
Ventura, S. [4 ]
Vignoli, C. [10 ]
机构
[1] Univ Aquila, I-67100 Laquila, Italy
[2] INFN, Laquila, Italy
[3] INFN Lab Nazl Gran Sasso, Assergi, Italy
[4] INFN Sez Padova, Padua, Italy
[5] Univ Padua, Padua, Italy
[6] Ist Nazl Fis Nucl, Padua, Italy
[7] Univ Pavia, I-27100 Pavia, Italy
[8] Ist Nazl Fis Nucl, I-27100 Pavia, Italy
[9] Princeton Univ, Princeton, NJ 08544 USA
[10] INFN Sez Pavia, Pavia, Italy
[11] Univ Naples Federico 2, Naples, Italy
[12] Ist Nazl Fis Nucl, I-80125 Naples, Italy
[13] INFN Sez Napoli, Naples, Italy
[14] IFJ PAN, Krakow, Poland
来源
JOURNAL OF INSTRUMENTATION | 2010年 / 5卷
基金
美国国家科学基金会;
关键词
Scintillators; scintillation and light emission processes (solid; gas and liquid scintillators); Noble-liquid detectors (scintillation; ionization two-phase); Instrument optimisation; XENON; LUMINESCENCE; YIELDS; DEPENDENCE; PARTICLES; NITROGEN; KRYPTON;
D O I
10.1088/1748-0221/5/05/P05003
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A dedicated test of the effects of Oxygen contamination in liquid Argon has been performed at the INFN-Gran Sasso Laboratory (LNGS, Italy) within the WArP R&D program. Two detectors have been used: the WArP 2.3 lt prototype and a small (0.7 lt) dedicated detector, coupled with a system for the injection of controlled amounts of gaseous Oxygen. O-2 contamination in LAr leads to depletion of both the free electron charge (via attachment process) and the scintillation light (via quenching and absorption mechanisms) available for ionization signal detection. Purpose of the test with the 0.7 lt detector was to detect the reduction of the long-lived component lifetime of the Argon scintillation light emission and of the overall light yield at increasing O-2 concentration. Data from the WArP prototype were used for determining the behavior of both the ionization electron lifetime and the scintillation long-lived component lifetime at decreasing O-2 concentration by the purification process activated in closed loop during the acquisition run. The electron lifetime measurements allowed to infer the O-2 content of the Argon and correlate it with the long-lived scintillation lifetime data. The effects of Oxygen contamination on the scintillation light have been thus extensively measured over a wide range of O-2 concentration, spanning from similar to 10(-3) ppm up to similar to 10 ppm.
引用
收藏
页数:20
相关论文
共 25 条
[11]   ESTIMATION OF ABSOLUTE PHOTON YIELDS IN LIQUID ARGON AND XENON FOR RELATIVISTIC (1 MEV) ELECTRONS [J].
DOKE, T ;
MASUDA, K ;
SHIBAMURA, E .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 291 (03) :617-620
[12]  
GROOSJEAN DE, 1997, PHYS REV B, V56, P6975
[13]   LIQUID AND SOLID ARGON, AND NITROGEN-DOPED LIQUID AND SOLID ARGON SCINTILLATORS [J].
HIMI, S ;
TAKAHASHI, T ;
RUANGEN, JZ ;
KUBOTA, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 203 (1-3) :153-157
[14]   EFFECT OF IONIZATION DENSITY ON THE TIME-DEPENDENCE OF LUMINESCENCE FROM LIQUID ARGON AND XENON [J].
HITACHI, A ;
TAKAHASHI, T ;
FUNAYAMA, N ;
MASUDA, K ;
KIKUCHI, J ;
DOKE, T .
PHYSICAL REVIEW B, 1983, 27 (09) :5279-5285
[15]   PRODUCTION AND TRANSPORT OF CONDUCTION ELECTRONS IN A LIQUID ARGON IONIZATION-CHAMBER [J].
HOFMANN, W ;
KLEIN, U ;
SCHULZ, M ;
SPENGLER, J ;
WEGENER, D .
NUCLEAR INSTRUMENTS & METHODS, 1976, 135 (01) :151-156
[16]   VARIATION OF SCINTILLATION DECAY IN LIQUID ARGON EXCITED BY ELECTRONS AND ALPHA-PARTICLES [J].
KUBOTA, S ;
HISHIDA, M ;
NOHARA, A .
NUCLEAR INSTRUMENTS & METHODS, 1978, 150 (03) :561-564
[17]   RECOMBINATION LUMINESCENCE IN LIQUID ARGON AND IN LIQUID XENON [J].
KUBOTA, S ;
NAKAMOTO, A ;
TAKAHASHI, T ;
HAMADA, T ;
SHIBAMURA, E ;
MIYAJIMA, M ;
MASUDA, K ;
DOKE, T .
PHYSICAL REVIEW B, 1978, 17 (06) :2762-2765
[18]   DYNAMICAL BEHAVIOR OF FREE-ELECTRONS IN THE RECOMBINATION PROCESS IN LIQUID ARGON, KRYPTON, AND XENON [J].
KUBOTA, S ;
HISHIDA, M ;
SUZUKI, M ;
RUAN, JZ .
PHYSICAL REVIEW B, 1979, 20 (08) :3486-3496
[19]   AVERAGE ENERGY EXPENDED PER ION-PAIR IN LIQUID ARGON [J].
MIYAJIMA, M ;
TAKAHASHI, T ;
KONNO, S ;
HAMADA, T ;
KUBOTA, S ;
SHIBAMUR.H ;
DOKE, T .
PHYSICAL REVIEW A, 1974, 9 (03) :1438-1443
[20]   ARGON, KRYPTON, AND XENON EXCIMER LUMINESCENCE - FROM THE DILUTE GAS TO THE CONDENSED PHASE [J].
MORIKAWA, E ;
REININGER, R ;
GURTLER, P ;
SAILE, V ;
LAPORTE, P .
JOURNAL OF CHEMICAL PHYSICS, 1989, 91 (03) :1469-1477