Stability of volar locking plate systems for AO type C3 fractures of the distal radius: biomechanical study in a cadaveric model

被引:26
|
作者
Kamei, Shuzo [1 ]
Osada, Denju [1 ]
Tamai, Kazuya [1 ]
Kato, Nakayuki [1 ]
Takai, Morimitsu [1 ]
Kameda, Masahiro [1 ]
Nohara, Yutaka [1 ]
机构
[1] Dokkyo Med Univ, Sch Med, Dept Orthopaed Surg, Mibu, Tochigi 3210293, Japan
关键词
FRAGMENT-SPECIFIC FIXATION; COMPRESSION PLATE; EXTERNAL FIXATION; DORSAL; SCREW;
D O I
10.1007/s00776-010-1466-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of the present study was to compare the relative stability of five volar locking plates (all of which are available for the treatment of intraarticular fractures of the distal radius) under loading conditions simulating the physiological forces that occur during early active mobilization. Five plating techniques were applied to surgically simulated AO type C3.2 distal radius fractures in formalin-fixed cadavers. The specimens were tested with a servohydraulic materials testing machine with 250 N of axial compression load for 3000 cycles. After cyclic loading, the specimens were loaded until they demonstrated failure in axial compression. The five fixation systems studied included a DRV locking plate (group 1), a Stellar plate (group 2), an Acu-Loc plate (group 3), AO Locking Distal Radius System 2.4 (group 4); and a Matrix SmartLock plate (group 5). None of the plate fixations tested failed during the cyclic loading. Group 2 had a higher elastic limit than groups 4 and 5. There were no significant differences among the five groups for the failure load. Failure occurred at the distal portion of the fixation system, at the ulnar side locking pin, or the locking screw was bent (groups 1, 2, 3); the ulnar side locking screw was broken (groups 3, 4); the locking screw became loose (group 4); and the ulnar side locking screw was uncoupled from the screw hole (group 5). All of the five volar plate fixation systems provided sufficient stability to permit 3000 repeated motions of the digits after surgery for AO type C3 distal radius fractures.
引用
收藏
页码:357 / 364
页数:8
相关论文
共 50 条
  • [41] Fracture lines and comminution zones in OTA/AO type 23C3 distal radius fractures: The distal radius map
    Misir, Abdulhamit
    Ozturk, Kahraman
    Kizkapan, Turan Bilge
    Yildiz, Kadir Ilker
    Gur, Volkan
    Sevencan, Ahmet
    JOURNAL OF ORTHOPAEDIC SURGERY, 2018, 26 (01)
  • [42] Volar Locking Plate versus External Fixation for Distal Radius Fractures: A Meta-analysis of Randomized Controlled Trials
    Fu, Qiang
    Zhu, Lei
    Yang, Peng
    Chen, Aimin
    INDIAN JOURNAL OF ORTHOPAEDICS, 2018, 52 (06) : 602 - 610
  • [43] Complications Following Volar Locking Plate Fixation of Distal Radius Fractures in Adults: A Systematic Review of Randomized Control Trials
    Nwosu, Chinemerem
    Rodriguez, Kaitlyn
    Zeng, Steven
    Klifto, Kevin M.
    Klifto, Christopher S.
    Ruch, David S.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2023, 48 (09): : 861 - 874
  • [44] Volar Locking Plate versus External Fixation for Distal Radius Fractures: A Meta-analysis of Randomized Controlled Trials
    Qiang Fu
    Lei Zhu
    Peng Yang
    Aimin Chen
    Indian Journal of Orthopaedics, 2018, 52 : 602 - 610
  • [45] Percutaneous pinning versus volar locking plate internal fixation for unstable distal radius fractures: a meta-analysis
    Peng, Fei
    Liu, Yuan-xiang
    Wan, Zhen-yu
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2018, 43 (02) : 158 - 167
  • [46] A Meta-analysis of Studies of Volar Locking Plate Fixation of Distal Radius Fractures: Conventional versus Minimally Invasive Plate Osteosynthesis
    Lee, Dong-Yeong
    Park, Young-Jin
    Park, Jin-Sung
    CLINICS IN ORTHOPEDIC SURGERY, 2019, 11 (02) : 208 - 219
  • [47] Surgical options for distal radius fractures of type C in elderly patients over 65 years old: a comparison of external fixation with Kirschner wires and volar locking plate
    He Zhang
    Man Liu
    Si-Yu Duan
    Hai-Rui Liang
    Rong-Da Xu
    Zhen-Cun Cai
    Journal of Orthopaedic Surgery and Research, 18
  • [48] Surgical options for distal radius fractures of type C in elderly patients over 65 years old: a comparison of external fixation with Kirschner wires and volar locking plate
    Zhang, He
    Liu, Man
    Duan, Si-Yu
    Liang, Hai-Rui
    Xu, Rong-Da
    Cai, Zhen-Cun
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [49] Biomechanical Analysis of Volar and Dorsal Double Locking Plates for Fixation in Comminuted Extra-articular Distal Radius Fractures: A 3D Finite Element Study
    Lin, Yu-Hao
    Lin, Chun-Li
    Kuo, Hsien-Nan
    Sun, Ming-Tsung
    Chen, Alvin Chao-Yu
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2012, 32 (05) : 349 - 355
  • [50] Use of Volar Locking Plate Versus Intramedullary Nailing for Fixation of Distal Radius Fractures: A Retrospective Analysis of Clinical and Radiographic Outcomes
    Calbiyik, Murat
    Ipek, Deniz
    MEDICAL SCIENCE MONITOR, 2018, 24 : 602 - 613