Stability of volar locking plate systems for AO type C3 fractures of the distal radius: biomechanical study in a cadaveric model

被引:26
|
作者
Kamei, Shuzo [1 ]
Osada, Denju [1 ]
Tamai, Kazuya [1 ]
Kato, Nakayuki [1 ]
Takai, Morimitsu [1 ]
Kameda, Masahiro [1 ]
Nohara, Yutaka [1 ]
机构
[1] Dokkyo Med Univ, Sch Med, Dept Orthopaed Surg, Mibu, Tochigi 3210293, Japan
关键词
FRAGMENT-SPECIFIC FIXATION; COMPRESSION PLATE; EXTERNAL FIXATION; DORSAL; SCREW;
D O I
10.1007/s00776-010-1466-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of the present study was to compare the relative stability of five volar locking plates (all of which are available for the treatment of intraarticular fractures of the distal radius) under loading conditions simulating the physiological forces that occur during early active mobilization. Five plating techniques were applied to surgically simulated AO type C3.2 distal radius fractures in formalin-fixed cadavers. The specimens were tested with a servohydraulic materials testing machine with 250 N of axial compression load for 3000 cycles. After cyclic loading, the specimens were loaded until they demonstrated failure in axial compression. The five fixation systems studied included a DRV locking plate (group 1), a Stellar plate (group 2), an Acu-Loc plate (group 3), AO Locking Distal Radius System 2.4 (group 4); and a Matrix SmartLock plate (group 5). None of the plate fixations tested failed during the cyclic loading. Group 2 had a higher elastic limit than groups 4 and 5. There were no significant differences among the five groups for the failure load. Failure occurred at the distal portion of the fixation system, at the ulnar side locking pin, or the locking screw was bent (groups 1, 2, 3); the ulnar side locking screw was broken (groups 3, 4); the locking screw became loose (group 4); and the ulnar side locking screw was uncoupled from the screw hole (group 5). All of the five volar plate fixation systems provided sufficient stability to permit 3000 repeated motions of the digits after surgery for AO type C3 distal radius fractures.
引用
收藏
页码:357 / 364
页数:8
相关论文
共 50 条
  • [31] Volar locking plate fixation versus Kirschner wire fixation in distal radius fractures: a meta-analysis
    Shao, Jin
    Kong, De-Ce
    Yang, Tie-Yi
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (08): : 16230 - +
  • [32] Mid-Term Results after Volar Plating of Distal Radius Fractures with a Newly Designed Locking Plate
    Wick, M.
    Wiesner, M.
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2010, 148 (01): : 66 - 71
  • [33] Early complications and radiological outcome after distal radius fractures stabilized by volar angular stable locking plate
    Quadlbauer, Stefan
    Pezzei, Ch.
    Jurkowitsch, J.
    Rosenauer, R.
    Pichler, A.
    Schaettin, S.
    Hausner, T.
    Leixnering, M.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2018, 138 (12) : 1773 - 1782
  • [34] Radiological, Clinical, and Functional Outcomes of Combined Dorsal and Volar Locking Plate Osteosynthesis for Complex Distal Radius Fractures
    Luedi, Simona
    Kurz, Charlotte
    Deforth, Manja
    Ghafoor, Haval
    Haefeli, Mathias
    Honigmann, Philipp
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2023, 48 (04): : 377 - 387
  • [35] Computed Tomography Evaluation of Distal Screw Penetration in Volar Locking Plate Fixation for Intra-Articular Distal Radius Fractures
    Kaneshiro, Yasunori
    Hyun, Seungho
    Yano, Koichi
    Yokoi, Takuya
    Sakanaka, Hideki
    Hidaka, Noriaki
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2023, 48 (06): : 553 - 558
  • [36] Biomechanical comparison of fixed-angle volar plate versus fixed-angle volar plate plus fragment-specific fixation in a cadaveric distal radius fracture model
    Grindel, Steven I.
    Wang, Mei
    Gerlach, Matthew
    McGrady, Linda M.
    Brown, Susan
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2007, 32A (02): : 194 - 199
  • [37] Multidrectional locking volar plate in distal radius fractures. Secondary loss of reduction - correct implantation is essential
    Michelitsch, C.
    Acklin, Y. P.
    Sommer, C.
    UNFALLCHIRURG, 2013, 116 (12): : 1123 - 1127
  • [38] Ligament-Sparing Volar Radiocarpal Arthrotomy During Distal Radius Fracture Repair: Biomechanical Implications on Wrist Stability in a Cadaveric Model
    Douleh, Diana G.
    Baldini, Todd
    Carry, Patrick
    Rogers, Michael
    Leversedge, Fraser J.
    Lauder, Alexander
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2024, 49 (06): : 613.e1 - 613.e10
  • [39] Size and stabilization of the dorsoulnar fragment in AO C3-type distal radius fractures
    Miyashima, Y.
    Kaneshiro, Y.
    Yano, K.
    Teraura, H.
    Sakanaka, H.
    Uemura, T.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 (11): : 2004 - 2008
  • [40] Biomechanical study of the fixation ability of the dorsal and volar locking plate for transverse metacarpal neck fractures
    Ho, Tsung-Yu
    Hsu, Cheng-En
    Wang, Wei-Chih
    Ting, Yen-Nien
    Tsai, Ming-Tzu
    Chiu, Yung-Cheng
    Hsu, Jui-Ting
    MEDICINE, 2023, 102 (36) : E34981