Thermal shielding performances of nano-structured intumescent coatings containing organo-modified layered double hydroxides

被引:38
作者
Han, Zhidong [1 ,2 ]
Fina, Alberto [1 ]
Malucelli, Giulio [1 ]
机构
[1] Politecn Torino, Dipartimento Sci Applicata & Tecnol, I-15121 Alessandria, Italy
[2] Harbin Univ Sci & Technol, Sch Mat Sci & Engn, Harbin 150040, Peoples R China
关键词
Intumescent coatings; Layered double hydroxides; Thermal shielding performance; Cone calorimetry; FIRE PROTECTION; CHAR FORMATION; RESISTANCE;
D O I
10.1016/j.porgcoat.2014.06.011
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Cone calorimetry tests performed at 50 kW/m(2) heat flux have been exploited for assessing the fire resistant properties of nano-structured intumescent coatings containing modified layered double hydroxides (hydrotalcites, LDHs) and deposited on steel plates. The effects of different types of modified hydrotalcites (i.e. magnesium-aluminum lactate hydrotalcite, magnesium-aluminum gluconate hydrotalcite, magnesium-aluminum hydrotalcite modified with a fatty acid, magnesium-aluminum hydrotalcite modified with rosin) on the thermal shielding performances of the intumescent coatings and their intumescent degree have been thoroughly discussed and compared with the pristine unfilled counterparts. More specifically, the coatings containing organo-modified LDHs showed better thermal shielding performances with respect to the reference intumescent coating; on the contrary, the use of unmodified hydrotalcite in the intumescent formulations was found detrimental. The thermal shielding performances of the coatings filled with modified LDHs were found to be strictly related to the intumescent degree developed during the cone calorimetry tests. In addition, it was possible to compare the thermal shielding performances of the nanofilled coatings by evaluating the temperatures achieved after 2000 s exposure to the 50 kW/m(2) heat flux of the cone: the thermal shielding performance sequence was LDH-GL>LDH-RS>LDH-LA>LDH-FA>LDH). Finally, the intumescent degree of the modified coatings was found to decrease with increasing the hydrotalcite content, hence lowering their thermal shielding performances. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:504 / 510
页数:7
相关论文
共 27 条
  • [11] Intumescent fire protective coating: Toward a better understanding of their mechanism of action
    Jimenez, M.
    Duquesne, S.
    Bourbigot, S.
    [J]. THERMOCHIMICA ACTA, 2006, 449 (1-2) : 16 - 26
  • [12] Kinetic analysis of the thermal degradation of an epoxy-based intumescent coating
    Jimenez, Maude
    Duquesne, Sophie
    Bourbigot, Serge
    [J]. POLYMER DEGRADATION AND STABILITY, 2009, 94 (03) : 404 - 409
  • [13] Recent developments in flame retardant polymeric coatings
    Liang, Shuyu
    Neisius, N. Matthias
    Gaan, Sabyasachi
    [J]. PROGRESS IN ORGANIC COATINGS, 2013, 76 (11) : 1642 - 1665
  • [14] Synthesis and characterization of water borne intumescent fire retardant varnish based on phosphate resin acid cold cured amino resin
    Ma, Zhiling
    Wang, Jiangjiang
    Chen, Shu
    Li, Xiaoying
    Ma, Haiyun
    [J]. PROGRESS IN ORGANIC COATINGS, 2012, 74 (03) : 608 - 614
  • [15] Investigation of char strength and expansion properties of an intumescent coating exposed to rapid heating rates
    Norgaard, Kristian Petersen
    Dam-Johansen, Kim
    Catala, Pere
    Kiil, Soren
    [J]. PROGRESS IN ORGANIC COATINGS, 2013, 76 (12) : 1851 - 1857
  • [16] Rives V., 2001, LAYERED DOUBLE HYDRO
  • [17] Some comments on the use of cone calorimeter data
    Schartel, B
    Bartholmai, M
    Knoll, U
    [J]. POLYMER DEGRADATION AND STABILITY, 2005, 88 (03) : 540 - 547
  • [18] A theoretical and experimental investigation of intumescent behaviour in protective coatings for structural steel
    Staggs, J. E. J.
    Crewe, R. J.
    Butler, R.
    [J]. CHEMICAL ENGINEERING SCIENCE, 2012, 71 : 239 - 251
  • [19] Influences of polymerization degree of ammonium polyphosphate on fire protection of waterborne intumescent fire resistive coating
    Wang, Guojian
    Wang, Yilong
    Yang, Jiayun
    [J]. SURFACE & COATINGS TECHNOLOGY, 2012, 206 (8-9) : 2275 - 2280
  • [20] Influences of glass flakes on fire protection and water resistance of waterborne intumescent fire resistive coating for steel structure
    Wang, Guojian
    Yang, Jiayun
    [J]. PROGRESS IN ORGANIC COATINGS, 2011, 70 (2-3) : 150 - 156