Dual-energy contrast enhanced digital mammography using a new approach for breast tissue canceling

被引:5
作者
Puong, Sylvie [1 ,2 ]
Bouchevreau, Xavier [3 ]
Patoureaux, Fanny [2 ]
Iordache, Razvan [2 ]
Muller, Serge [2 ]
机构
[1] Univ Paris 11, Bat 425, Orsay, France
[2] GE Hlthcare, Buc, France
[3] Altran, Paris, France
来源
MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3 | 2007年 / 6510卷
关键词
digital mammography; contrast medium; contrast enhanced digital mammography; dual-energy; algorithm description;
D O I
10.1117/12.710133
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this study, we propose a novel approach to dual-energy contrast-enhanced digital mammography, with the development of a dual-energy recombination algorithm based on an image chain model and the determination of the associated optimal low and high-energy techniques. Our method produces clutter-free iodine-equivalent images and includes thickness correction near the breast border. After the algorithm description, the optimal low and high-energy acquisition techniques are determined to obtain a compromise between image quality and glandular dose. The low and high-energy techniques were chosen to minimize the glandular dose for a target Signal Difference to Noise Ratio (SDNR) in the dual-energy recombined image. The theoretical derivation of the iodine SDNR in the recombined image allowed the prediction of the optimal low and high-energy techniques. Depending on the breast thickness and glandular percentage, the optimal low-energy kVp and mAs ranged from 24kVp (Mo/Mo or Mo/Rh) to 35kVp (Rh/Rh), and from 60 to 90mAs respectively, and the high-energy kVp and mAs ranged from 40kVp to 47kVp (Mo/Cu), and from 80mAs to 290mAs. We proved the better :performance of our algorithm compared to the classic weighted logarithmic subtraction method in terms of patient dose and also in terms of texture cancelation, through the use of artificial textured images. Values of iodine contrast measured on phantom were close to the expected iodine thickness. Good correlation was found between the measured and theoretical iodine SDNR in the dual-energy images, which validates our theoretical optimization of the acquisition techniques.
引用
收藏
页数:12
相关论文
共 22 条
[1]   ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY [J].
ALVAREZ, RE ;
MACOVSKI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :733-744
[2]  
[Anonymous], 2001, Probability, Random Variables, and Stochastic Processes
[3]   COMPUTATION OF BREMSSTRAHLUNG X-RAY-SPECTRA AND COMPARISON WITH SPECTRA MEASURED WITH A GE(LI) DETECTOR [J].
BIRCH, R ;
MARSHALL, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (03) :505-517
[4]   DUAL-ENERGY MAMMOGRAPHY - A DETECTOR ANALYSIS [J].
BOONE, JM ;
SHABER, GS ;
TECOTZKY, M .
MEDICAL PHYSICS, 1990, 17 (04) :665-675
[5]   COLOR MAMMOGRAPHY - IMAGE GENERATION AND RECEIVER OPERATING CHARACTERISTIC EVALUATION [J].
BOONE, JM .
INVESTIGATIVE RADIOLOGY, 1991, 26 (06) :521-527
[6]   DUAL-ENERGY DIGITAL MAMMOGRAPHY UTILIZING STIMULATED PHOSPHOR COMPUTED RADIOGRAPHY [J].
BRETTLE, DS ;
COWEN, AR .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (11) :1989-2004
[7]   Bach, breasts, and power-law processes [J].
Burgess, AE .
MEDICAL IMAGING 2001: IMAGE PERCEPTION AND PERFORMANCE, 2001, 4324 :103-113
[8]  
Cranley K., 1997, CATALOGUE DIAGNOSTIC
[9]   SINGLE-EXPOSURE DUAL-ENERGY COMPUTED RADIOGRAPHY - IMPROVED DETECTION AND PROCESSING [J].
ERGUN, DL ;
MISTRETTA, CA ;
BROWN, DE ;
BYSTRIANYK, RT ;
SZE, WK ;
KELCZ, F ;
NAIDICH, DP .
RADIOLOGY, 1990, 174 (01) :243-249
[10]   CORRELATION BETWEEN CONTRAST ENHANCEMENT IN DYNAMIC MAGNETIC-RESONANCE-IMAGING OF THE BREAST AND TUMOR ANGIOGENESIS [J].
FROUGE, C ;
GUINEBRETIERE, JM ;
CONTESSO, G ;
DIPAOLA, R ;
BLERY, M .
INVESTIGATIVE RADIOLOGY, 1994, 29 (12) :1043-1049