Square wave voltammetric determination of nitrofurantoin in pharmaceutical formulations on highly boron-doped diamond electrodes at different boron-doping contents

被引:56
作者
de Lima-Neto, Pedro [1 ]
Correia, Adriana N. [1 ]
Portela, Rafael R. [1 ]
Juliao, Murilo da Silva [2 ]
Linhares-Junior, Gilberto F. [3 ]
de Lima, Janete E. S. [3 ]
机构
[1] Univ Fed Ceara, Ctr Ciencias, Dept Quim Analit & Fisicoquim, BR-60455970 Fortaleza, Ceara, Brazil
[2] Univ Estadual Vale Acarau, Ctr Ciencias Exatas & Tecnol, BR-62040370 Sobral, CE, Brazil
[3] Univ Fed Ceara, Dept Farm, Fac Farm Odontol & Enfermagem, BR-60430370 Fortaleza, Ceara, Brazil
关键词
Boron-doped diamond film electrode; Nitrofurantoin; Cyclic voltammetry; Square wave voltammetry; Electroanalytical determination; ELECTROANALYTICAL CHEMISTRY; CARBON NANOTUBES; URINE; BEHAVIOR; ELECTROCHEMISTRY; PLASMA; DRUG;
D O I
10.1016/j.talanta.2009.10.014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The influence of the boron-doping levels in boron-doped diamond film electrodes on the electrochemical response of nitrofurantoin (NFT) and the development of an electroanalytical procedure for NET determination were investigated. The investigations were carried out using the techniques of cyclic voltammetry and square wave voltammetry on diamond film electrodes with different boron-doping levels (i e.5000. 10,000 and 20,000 mg L(-1)) The level of boron-doping ill the diamond film electrodes influenced the electrochemical reduction of NET. The appropriate cyclic voltammetric response of NET was obtained with Britton-Robinson buffer at pH 4 and for diamond films doped with 10,000 and 20,000 mg L-1 of boron These two films were selected for the development of the electroanalytical procedure. The use of square wave voltammetry with the optimized parameters demonstrated a good linear relationship between the peak current and the NET concentration for a wide range of concentration. The lower limit of detection for the electrodes doped with 10,000 and 20.000 mg L(-1) of boron were 269 x 10(-8) mol L(-1) (6 40 mu g L(-1)) and 8 15 x 10(-9) mol L(-1) (1 94 mu g L(-1)), respectively. while the lower limits of quantification were 8.96 x 10(-8) mol L(-1) (21 33 mu g L(-1)) and 2.72 x 10(-8) mol L(-1) (6.47 mu g L(-1)), respectively. The applicability of the proposed procedure was tested using a commercial pharmaceutical formulation of NFT, and the results were compared with the procedure recommended by the British Pharmacopeia. The proposed procedure was sensitive, accurate and precise for analysis of NET and did not require complex preparations or renovations of the electrode surface This presents the advantage of eliminating mercury waste and minimizing the adsorptive problems related to the use of other electrodic solid surfaces. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1730 / 1736
页数:7
相关论文
共 36 条
  • [11] Selective electrochemical behavior of highly conductive boron-doped diamond electrodes for fluvastatin sodium oxidation
    Dogan, Burcu
    Tuncel, Secil
    Uslu, Bengi
    Oezkan, Sibel A.
    [J]. DIAMOND AND RELATED MATERIALS, 2007, 16 (09) : 1695 - 1704
  • [12] Kinetics study of diamond electrodes at different levels of boron doping as quasi-reversible systems
    Ferreira, NG
    Silva, LLG
    Corat, EJ
    Trava-Airoldi, VJ
    [J]. DIAMOND AND RELATED MATERIALS, 2002, 11 (08) : 1523 - 1531
  • [13] Effect of anodic and cathodic treatments on the charge transfer of boron doped diamond electrodes
    Girard, H.
    Simon, N.
    Ballutaud, D.
    Herlern, M.
    Etcheberry, A.
    [J]. DIAMOND AND RELATED MATERIALS, 2007, 16 (02) : 316 - 325
  • [14] Electrochemistry and electroanalytical applications of carbon nanotubes: A review
    Gong, KP
    Yan, YM
    Zhang, MN
    Su, L
    Xiong, SX
    Mao, LQ
    [J]. ANALYTICAL SCIENCES, 2005, 21 (12) : 1383 - 1393
  • [15] Voltammetric determination of antibacterial nitro-compounds at activated carbon fibre microelectrodes
    Guzmán, A
    Agüí, L
    Pedrero, M
    Yáñez-Sedeño, P
    Pingarrón, JM
    [J]. ELECTROANALYSIS, 2004, 16 (21) : 1763 - 1770
  • [16] Determination of nitrofurantoin drug in pharmaceutical formulation and biological fluids by square-wave cathodic adsorptive stripping voltammetry
    Hammam, E
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 30 (03) : 651 - 659
  • [17] International Council or Harmonisation of Technical Requirements for Pharmaceuticals for Human Use (ICH) International Conference on Harmonization, 1996, INT C HARM TECHN REQ
  • [18] Stripping voltammetric behaviour of toxic drug nitrofurantoin
    Jain, Rajeev
    Dwivedi, Ashish
    Mishra, Ritesh
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2009, 169 (1-3) : 667 - 672
  • [19] JONES BM, 1965, J PHARM PHARM S, V17, P52
  • [20] Voltammetric Behavior of nitrofurazone at highly boron doped diamond electrode
    Juliao, MSD
    Almeida, ÉC
    La Scalea, MA
    Ferreira, NG
    Compton, RG
    Serrano, SHP
    [J]. ELECTROANALYSIS, 2005, 17 (03) : 269 - 274