Investigation of a Multi-Cone Variant of the Standard Cone Frustum Test for 5-Axis Machine Tools

被引:4
作者
Keaveney, Shane [1 ]
Connolly, Pat [1 ]
Ahearne, Eamonn [1 ]
Byrne, Gerald [1 ]
机构
[1] Natl Univ Ireland Univ Coll Dublin, UCD Engn & Mat Sci Ctr, Dublin 4, Ireland
来源
6TH CIRP INTERNATIONAL CONFERENCE ON HIGH PERFORMANCE CUTTING (HPC2014) | 2014年 / 14卷
关键词
Cone Frustum machining; Multi-Cone Artefact; 5-axis Machine Error; GEOMETRIC ERRORS; CENTERS;
D O I
10.1016/j.procir.2014.03.038
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In the domain of CNC (Computer Numerical Control) machining, both positional and contouring accuracy are of extreme importance. Moreover, the need for higher precision and more complex freeform surfaces has reduced component geometric tolerances and increased the demand for higher process capabilities. 5-axis machine tools (or machining if you prefer) have enabled realization of these surfaces availing of full tool posture control, while also reducing set-up and production time. However, identification and quantification of associated errors is a challenge, often time consuming, with full physical correction near impossible. This paper's focus is on the repeatability and functionality of the cone frustum acceptance test presented in the draft standard 2012, ISO 10791-7. This work builds on the state of the art and proposes that the artefact used in the standard cone frustum test be developed to include two or more conical surfaces. Explanation and investigation of the Multi-Cone artefact, with machining results on a Mori Seiki NMV1500, are reported. The results show the repeatability of the cone frustum test and the potential for diagnostic benefits using the Multi-Cone artefact. (C) 2014 Elsevier B.V.
引用
收藏
页码:317 / 322
页数:6
相关论文
共 14 条
[1]  
Bossoni S., 2009, DYNAMIC EVALUATION O
[2]   Increasing of surface quality in friction free-form surfaces of knee prosthesis [J].
Chaves-Jacob, J. ;
Linares, J. M. ;
Sprauel, J. M. .
CIRP ANNALS-MANUFACTURING TECHNOLOGY, 2011, 60 (01) :531-534
[3]   Optimal strategy for finishing impeller blades using 5-axis machining [J].
Chaves-Jacob, Julien ;
Poulachon, Gerard ;
Duc, Emmanuel .
INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2012, 58 (5-8) :573-583
[4]   Influence of position-dependent geometric errors of rotary axes on a machining test of cone frustum by five-axis machine tools [J].
Hong, Cefu ;
Ibaraki, Soichi ;
Matsubara, Atsushi .
PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2011, 35 (01) :1-11
[5]  
Keaveney S., 2013, P MTTRF 2013 M
[6]   KINEMATIC MODELING OF QUASI-STATIC ERRORS OF 3-AXIS MACHINING CENTERS [J].
KIRIDENA, VSB ;
FERREIRA, PM .
INTERNATIONAL JOURNAL OF MACHINE TOOLS & MANUFACTURE, 1994, 34 (01) :85-100
[7]   Total ballbar dynamic tests for five-axis CNC machine tools [J].
Lei, W. T. ;
Paung, I. M. ;
Yu, Chen-Chi .
INTERNATIONAL JOURNAL OF MACHINE TOOLS & MANUFACTURE, 2009, 49 (06) :488-499
[8]   Modeling and analysis of servo dynamics errors on measuring paths of five-axis machine tools [J].
Lin, Ming-Tzong ;
Wu, Shih-Kai .
INTERNATIONAL JOURNAL OF MACHINE TOOLS & MANUFACTURE, 2013, 66 :1-14
[9]  
Micheal Gebhardt e.a, MTTRF C P 2012, P6
[10]   Analysis of interaction between geometry and efficiency of impeller pump using rapid prototyping [J].
Rajenthirakumar, D. ;
Jagadeesh, K. A. .
INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2009, 44 (9-10) :890-899